{"title":"DOLD BA 9054 voltage relay","description":"\u003cp\u003eThe DOLD series \u003cstrong\u003eBA 9054\u003c\/strong\u003e (also BA9054) comprises 328 versions at IAM24 – mainly voltage relays and battery symmetry monitors. The variants differ mainly in supply voltage, measuring or setting range and contact configuration. All devices are genuine products from E. DOLD \u0026amp; Söhne; the type and DOLD article number are shown on every product page.\u003c\/p\u003e\u003c!--iam24-serie--\u003e\u003ch2\u003eDOLD BA 9054: versions at a glance\u003c\/h2\u003e\u003cp\u003eSpellings: \u003cstrong\u003eBA 9054\u003c\/strong\u003e · BA9054 · BA-9054. Each version has its own seven-digit DOLD article number (e.g. 0051065), which identifies the device unambiguously.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left\"\u003eType\u003c\/th\u003e\n\u003cth style=\"text-align:left\"\u003eVersions\u003c\/th\u003e\n\u003cth style=\"text-align:left\"\u003eExample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/010\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-010-dc1-10v-ac-dc24-80v-0051065\"\u003eDC1-10V AC\/DC24-80V voltage relay\u003c\/a\u003e (0051065)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/012\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-012-ac15-150mv-uh-ac24v-0053692\"\u003eAC15-150MV UH AC24V voltage relay\u003c\/a\u003e (0053692)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/011\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-011-ac15-150mv-uh-ac110v-0053657\"\u003eAC15-150mV UH AC110V voltage relay\u003c\/a\u003e (0053657)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/013\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-013-ac15-150mv-uh-ac230v-0053723\"\u003eAC15-150MV UH AC230V voltage relay\u003c\/a\u003e (0053723)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/112\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-112-ac25-250v-ac-dc80-230v-0054384\"\u003eAC25-250V AC\/DC80-230V voltage relay\u003c\/a\u003e (0054384)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/110\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-110-ac0-5-5v-uh-ac230v-0053876\"\u003eAC0,5-5V UH AC230V voltage relay\u003c\/a\u003e (0053876)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/113\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-113-ac0-5-5v-ac230v-0055820\"\u003eAC0,5-5V AC230V voltage relay\u003c\/a\u003e (0055820)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/023\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-023-ac70-700v-uh-ac230v-0052520\"\u003eAC70-700V UH AC230V voltage relay\u003c\/a\u003e (0052520)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/022\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-022-ac70-700v-uh-ac230v-0054933\"\u003eAC70-700V UH AC230V voltage relay\u003c\/a\u003e (0054933)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/610\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-610-ac15-150mv-uh-ac230v-0055857\"\u003eAC15-150mV UH AC230V voltage relay\u003c\/a\u003e (0055857)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/024\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-024-ac70-700v-uh-ac230v-0053746\"\u003eAC70-700V UH AC230V voltage relay\u003c\/a\u003e (0053746)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBA 9054\/021\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-ba9054-021-ac70-700v-uh-ac230v-0053747\"\u003eAC70-700V UH AC230V voltage relay\u003c\/a\u003e (0053747)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eCommon supply or measuring voltages in this series:\u003c\/strong\u003e AC\/DC24-80V (74), AC230V (73), AC\/DC80-230V (66), AC25-250V (61), AC5-50V (44), AC50-500V (41), AC0,5-5V (32), AC110V (28).\u003c\/p\u003e\u003ch3\u003eHow to find the right version\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eSelect the type suffix (“Type” column); it is shown on the rating plate of the existing device.\u003c\/li\u003e\n\u003cli\u003eCompare the measuring or setting range and the supply voltage – both are stated in the product title.\u003c\/li\u003e\n\u003cli\u003eTo be sure, compare the DOLD article number and check the data sheet on the product page.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eCan’t find your version? \u003ca href=\"\/en\/pages\/individuelles-angebot\"\u003eRequest an individual quotation\u003c\/a\u003e – also for larger quantities.\u003c\/p\u003e\u003cp\u003eMore from this area: \u003ca href=\"\/en\/collections\/dold-messrelais-zur-spannungsueberwachung\"\u003eDOLD measuring relays for voltage monitoring\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dold#baureihen\"\u003eAll DOLD series A–Z\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"dold-ba9054-010-dc1-10v-ac-dc24-80v-0051065","title":"DOLD BA9054\/010 DC1-10V AC\/DC24-80V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051065\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 DC1-10V AC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051065\u003c\/strong\u003e (type BA9054\/010 DC1-10V AC\/DC24-80V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 DC1-10V AC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 DC1-10V AC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 DC1-10V AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051065 (BA9054\/010 DC1-10V AC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 DC1-10V AC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 DC1-10V AC\/DC24-80V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 DC1-10V AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 DC1-10V AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401673773405,"sku":"0051065","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-023-ac70-700v-uh-ac230v-0052520","title":"DOLD BA9054\/023 AC70-700V UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0052520\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/023 AC70-700V UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0052520\u003c\/strong\u003e (type BA9054\/023 AC70-700V UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 70 - 700 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUndervoltage relay. Open-circuit principle. Switching delay at hysteresis value. Overloadable up to AC 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0052520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/023 AC70-700V UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/023 AC70-700V UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/023 AC70-700V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0052520 (BA9054\/023 AC70-700V UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/023 AC70-700V UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/023 AC70-700V UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/023 AC70-700V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/023 AC70-700V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401703395677,"sku":"0052520","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac230v-0053323","title":"DOLD BA9054\/010 AC0,5-5V UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053323\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053323\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053323 (BA9054\/010 AC0,5-5V UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC230V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403072999773,"sku":"0053323","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-ac-dc80-230v-0053463","title":"DOLD BA9054\/010 AC0,5-5V AC\/DC80-230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053463\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V AC\/DC80-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053463\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V AC\/DC80-230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 80 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V AC\/DC80-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V AC\/DC80-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053463 (BA9054\/010 AC0,5-5V AC\/DC80-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V AC\/DC80-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V AC\/DC80-230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403076768093,"sku":"0053463","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac15-150mv-ac-dc80-230v-0053606","title":"DOLD BA9054\/010 AC15-150MV AC\/DC80-230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053606\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC15-150MV AC\/DC80-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053606\u003c\/strong\u003e (type BA9054\/010 AC15-150MV AC\/DC80-230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 80 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 15 - 150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053606\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC15-150MV AC\/DC80-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC15-150MV AC\/DC80-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC15-150MV AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053606 (BA9054\/010 AC15-150MV AC\/DC80-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC15-150MV AC\/DC80-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC15-150MV AC\/DC80-230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC15-150MV AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC15-150MV AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403080831325,"sku":"0053606","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500mv-uh-ac110v-0053607","title":"DOLD BA9054\/010 AC50-500MV UH AC110V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053607\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500MV UH AC110V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053607\u003c\/strong\u003e (type BA9054\/010 AC50-500MV UH AC110V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053607\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500MV UH AC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500MV UH AC110V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500MV UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053607 (BA9054\/010 AC50-500MV UH AC110V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500MV UH AC110V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500MV UH AC110V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500MV UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500MV UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403080864093,"sku":"0053607","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500mv-uh-ac230v-0053608","title":"DOLD BA9054\/010 AC50-500MV UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053608\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500MV UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053608\u003c\/strong\u003e (type BA9054\/010 AC50-500MV UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500MV UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500MV UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500MV UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053608 (BA9054\/010 AC50-500MV UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500MV UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500MV UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500MV UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500MV UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403080896861,"sku":"0053608","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500mv-uh-ac240v-0053609","title":"DOLD BA9054\/010 AC50-500MV UH AC240V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053609\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500MV UH AC240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053609\u003c\/strong\u003e (type BA9054\/010 AC50-500MV UH AC240V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053609\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500MV UH AC240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500MV UH AC240V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500MV UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053609 (BA9054\/010 AC50-500MV UH AC240V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500MV UH AC240V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500MV UH AC240V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500MV UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500MV UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403080929629,"sku":"0053609","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500mv-uhac-dc24-80v-0053610","title":"DOLD BA9054\/010 AC50-500MV UHAC\/DC24-80V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053610\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500MV UHAC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053610\u003c\/strong\u003e (type BA9054\/010 AC50-500MV UHAC\/DC24-80V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500MV UHAC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500MV UHAC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500MV UHAC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053610 (BA9054\/010 AC50-500MV UHAC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC50-500MV UHAC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500MV UHAC\/DC24-80V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500MV UHAC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500MV UHAC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403080995165,"sku":"0053610","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500mv-ac-dc80-230v-0053611","title":"DOLD BA9054\/010 AC50-500MV AC\/DC80-230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053611\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500MV AC\/DC80-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053611\u003c\/strong\u003e (type BA9054\/010 AC50-500MV AC\/DC80-230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 80 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053611\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500MV AC\/DC80-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500MV AC\/DC80-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500MV AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053611 (BA9054\/010 AC50-500MV AC\/DC80-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC50-500MV AC\/DC80-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500MV AC\/DC80-230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500MV AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500MV AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081027933,"sku":"0053611","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac24v-0053612","title":"DOLD BA9054\/010 AC0,5-5V UH AC24V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053612\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053612\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC24V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053612 (BA9054\/010 AC0,5-5V UH AC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC24V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081060701,"sku":"0053612","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac42v-0053613","title":"DOLD BA9054\/010 AC0,5-5V UH AC42V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053613\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC42V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053613\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC42V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 42 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053613\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC42V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC42V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053613 (BA9054\/010 AC0,5-5V UH AC42V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC42V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC42V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081093469,"sku":"0053613","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac110v-0053614","title":"DOLD BA9054\/010 AC0,5-5V UH AC110V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053614\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC110V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053614\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC110V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053614\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC110V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053614 (BA9054\/010 AC0,5-5V UH AC110V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC110V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC110V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081126237,"sku":"0053614","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac240v-0053615","title":"DOLD BA9054\/010 AC0,5-5V UH AC240V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053615\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053615\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC240V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC240V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053615 (BA9054\/010 AC0,5-5V UH AC240V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC240V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC240V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081159005,"sku":"0053615","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac-dc24-80v-0053616","title":"DOLD BA9054\/010 AC0,5-5V UH AC\/DC24-80V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053616\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053616\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC\/DC24-80V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053616\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053616 (BA9054\/010 AC0,5-5V UH AC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC\/DC24-80V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081191773,"sku":"0053616","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac115v-0053618","title":"DOLD BA9054\/010 AC0,5-5V UH AC115V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053618\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC115V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053618\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC115V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC115V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC115V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053618 (BA9054\/010 AC0,5-5V UH AC115V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC115V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC115V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC115V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC115V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081257309,"sku":"0053618","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac0-5-5v-uh-ac127v-0053619","title":"DOLD BA9054\/010 AC0,5-5V UH AC127V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053619\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC0,5-5V UH AC127V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053619\u003c\/strong\u003e (type BA9054\/010 AC0,5-5V UH AC127V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 127 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 0.5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053619\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC0,5-5V UH AC127V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC0,5-5V UH AC127V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC0,5-5V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053619 (BA9054\/010 AC0,5-5V UH AC127V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC0,5-5V UH AC127V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC0,5-5V UH AC127V is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC0,5-5V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC0,5-5V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081322845,"sku":"0053619","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac1-10v-uh-ac24v-0053620","title":"DOLD BA9054\/010 AC1-10V UH AC24V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053620\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC1-10V UH AC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053620\u003c\/strong\u003e (type BA9054\/010 AC1-10V UH AC24V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC1-10V UH AC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC1-10V UH AC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC1-10V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053620 (BA9054\/010 AC1-10V UH AC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC1-10V UH AC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC1-10V UH AC24V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC1-10V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC1-10V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081355613,"sku":"0053620","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac1-10v-uh-ac42v-0053621","title":"DOLD BA9054\/010 AC1-10V UH AC42V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053621\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC1-10V UH AC42V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053621\u003c\/strong\u003e (type BA9054\/010 AC1-10V UH AC42V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 42 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053621\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC1-10V UH AC42V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC1-10V UH AC42V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC1-10V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053621 (BA9054\/010 AC1-10V UH AC42V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC1-10V UH AC42V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC1-10V UH AC42V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC1-10V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC1-10V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081388381,"sku":"0053621","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac1-10v-uh-ac110v-0053622","title":"DOLD BA9054\/010 AC1-10V UH AC110V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053622\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC1-10V UH AC110V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053622\u003c\/strong\u003e (type BA9054\/010 AC1-10V UH AC110V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053622\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC1-10V UH AC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC1-10V UH AC110V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC1-10V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053622 (BA9054\/010 AC1-10V UH AC110V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC1-10V UH AC110V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC1-10V UH AC110V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC1-10V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC1-10V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081453917,"sku":"0053622","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac1-10v-uh-ac230v-0053623","title":"DOLD BA9054\/010 AC1-10V UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053623\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC1-10V UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053623\u003c\/strong\u003e (type BA9054\/010 AC1-10V UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC1-10V UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC1-10V UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC1-10V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053623 (BA9054\/010 AC1-10V UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC1-10V UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC1-10V UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC1-10V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC1-10V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081486685,"sku":"0053623","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac1-10v-uh-ac240v-0053624","title":"DOLD BA9054\/010 AC1-10V UH AC240V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053624\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC1-10V UH AC240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053624\u003c\/strong\u003e (type BA9054\/010 AC1-10V UH AC240V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC1-10V UH AC240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC1-10V UH AC240V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC1-10V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053624 (BA9054\/010 AC1-10V UH AC240V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC1-10V UH AC240V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC1-10V UH AC240V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC1-10V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC1-10V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081519453,"sku":"0053624","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac1-10v-uh-ac-dc24-80v-0053625","title":"DOLD BA9054\/010 AC1-10V UH AC\/DC24-80V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053625\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC1-10V UH AC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053625\u003c\/strong\u003e (type BA9054\/010 AC1-10V UH AC\/DC24-80V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC1-10V UH AC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC1-10V UH AC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC1-10V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053625 (BA9054\/010 AC1-10V UH AC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC1-10V UH AC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC1-10V UH AC\/DC24-80V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC1-10V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC1-10V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081552221,"sku":"0053625","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac1-10v-uh-ac-dc80-230v-0053626","title":"DOLD BA9054\/010 AC1-10V UH AC\/DC80-230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053626\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC1-10V UH AC\/DC80-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053626\u003c\/strong\u003e (type BA9054\/010 AC1-10V UH AC\/DC80-230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 80 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 1 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC1-10V UH AC\/DC80-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC1-10V UH AC\/DC80-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC1-10V UH AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053626 (BA9054\/010 AC1-10V UH AC\/DC80-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC1-10V UH AC\/DC80-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC1-10V UH AC\/DC80-230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC1-10V UH AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC1-10V UH AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081584989,"sku":"0053626","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac5-50v-uh-ac24v-0053627","title":"DOLD BA9054\/010 AC5-50V UH AC24V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053627\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC5-50V UH AC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053627\u003c\/strong\u003e (type BA9054\/010 AC5-50V UH AC24V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 5 - 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC5-50V UH AC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC5-50V UH AC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC5-50V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053627 (BA9054\/010 AC5-50V UH AC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC5-50V UH AC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC5-50V UH AC24V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC5-50V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC5-50V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081617757,"sku":"0053627","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac5-50v-uh-ac42v-0053628","title":"DOLD BA9054\/010 AC5-50V UH AC42V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053628\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC5-50V UH AC42V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053628\u003c\/strong\u003e (type BA9054\/010 AC5-50V UH AC42V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 42 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 5 - 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC5-50V UH AC42V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC5-50V UH AC42V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC5-50V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053628 (BA9054\/010 AC5-50V UH AC42V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC5-50V UH AC42V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC5-50V UH AC42V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC5-50V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC5-50V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081716061,"sku":"0053628","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac5-50v-uh-ac48v-0053629","title":"DOLD BA9054\/010 AC5-50V UH AC48V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053629\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC5-50V UH AC48V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053629\u003c\/strong\u003e (type BA9054\/010 AC5-50V UH AC48V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 5 - 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC5-50V UH AC48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC5-50V UH AC48V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC5-50V UH AC48V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053629 (BA9054\/010 AC5-50V UH AC48V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC5-50V UH AC48V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC5-50V UH AC48V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC5-50V UH AC48V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC5-50V UH AC48V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081748829,"sku":"0053629","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac5-50v-uh-ac110v-0053630","title":"DOLD BA9054\/010 AC5-50V UH AC110V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053630\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC5-50V UH AC110V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053630\u003c\/strong\u003e (type BA9054\/010 AC5-50V UH AC110V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 5 - 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC5-50V UH AC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC5-50V UH AC110V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC5-50V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053630 (BA9054\/010 AC5-50V UH AC110V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC5-50V UH AC110V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC5-50V UH AC110V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC5-50V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC5-50V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081781597,"sku":"0053630","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac5-50v-uh-ac230v-0053631","title":"DOLD BA9054\/010 AC5-50V UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053631\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC5-50V UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053631\u003c\/strong\u003e (type BA9054\/010 AC5-50V UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 5 - 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053631\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC5-50V UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC5-50V UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC5-50V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053631 (BA9054\/010 AC5-50V UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC5-50V UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC5-50V UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC5-50V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC5-50V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081814365,"sku":"0053631","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac5-50v-uh-ac240v-0053632","title":"DOLD BA9054\/010 AC5-50V UH AC240V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053632\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC5-50V UH AC240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053632\u003c\/strong\u003e (type BA9054\/010 AC5-50V UH AC240V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 5 - 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC5-50V UH AC240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC5-50V UH AC240V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC5-50V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053632 (BA9054\/010 AC5-50V UH AC240V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC5-50V UH AC240V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC5-50V UH AC240V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC5-50V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC5-50V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081847133,"sku":"0053632","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-uh-ac24v-0053635","title":"DOLD BA9054\/010 AC25-250V UH AC24V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053635\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V UH AC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053635\u003c\/strong\u003e (type BA9054\/010 AC25-250V UH AC24V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V UH AC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V UH AC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053635 (BA9054\/010 AC25-250V UH AC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC25-250V UH AC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V UH AC24V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081879901,"sku":"0053635","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-uh-ac42v-0053636","title":"DOLD BA9054\/010 AC25-250V UH AC42V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053636\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V UH AC42V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053636\u003c\/strong\u003e (type BA9054\/010 AC25-250V UH AC42V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 42 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V UH AC42V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V UH AC42V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053636 (BA9054\/010 AC25-250V UH AC42V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC25-250V UH AC42V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V UH AC42V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V UH AC42V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403081912669,"sku":"0053636","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-uh-ac110v-0053637","title":"DOLD BA9054\/010 AC25-250V UH AC110V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053637\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V UH AC110V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053637\u003c\/strong\u003e (type BA9054\/010 AC25-250V UH AC110V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053637\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V UH AC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V UH AC110V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053637 (BA9054\/010 AC25-250V UH AC110V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC25-250V UH AC110V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V UH AC110V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082010973,"sku":"0053637","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-uh-ac127v-0053638","title":"DOLD BA9054\/010 AC25-250V UH AC127V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053638\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V UH AC127V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053638\u003c\/strong\u003e (type BA9054\/010 AC25-250V UH AC127V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 127 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V UH AC127V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V UH AC127V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053638 (BA9054\/010 AC25-250V UH AC127V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC25-250V UH AC127V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V UH AC127V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082043741,"sku":"0053638","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-uh-ac230v-0053639","title":"DOLD BA9054\/010 AC25-250V UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053639\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053639\u003c\/strong\u003e (type BA9054\/010 AC25-250V UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053639 (BA9054\/010 AC25-250V UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC25-250V UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082076509,"sku":"0053639","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-uh-ac240v-0053640","title":"DOLD BA9054\/010 AC25-250V UH AC240V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053640\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V UH AC240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053640\u003c\/strong\u003e (type BA9054\/010 AC25-250V UH AC240V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V UH AC240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V UH AC240V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053640 (BA9054\/010 AC25-250V UH AC240V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC25-250V UH AC240V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V UH AC240V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082109277,"sku":"0053640","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-uh-ac-dc24-80v-0053641","title":"DOLD BA9054\/010 AC25-250V UH AC\/DC24-80V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053641\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V UH AC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053641\u003c\/strong\u003e (type BA9054\/010 AC25-250V UH AC\/DC24-80V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053641\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V UH AC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V UH AC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053641 (BA9054\/010 AC25-250V UH AC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC25-250V UH AC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V UH AC\/DC24-80V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082142045,"sku":"0053641","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac25-250v-ac-dc80-230v-0053642","title":"DOLD BA9054\/010 AC25-250V AC\/DC80-230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053642\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC25-250V AC\/DC80-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053642\u003c\/strong\u003e (type BA9054\/010 AC25-250V AC\/DC80-230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 80 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 25 - 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053642\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC25-250V AC\/DC80-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC25-250V AC\/DC80-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC25-250V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053642 (BA9054\/010 AC25-250V AC\/DC80-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC25-250V AC\/DC80-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC25-250V AC\/DC80-230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC25-250V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC25-250V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082174813,"sku":"0053642","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-uh-ac24v-0053643","title":"DOLD BA9054\/010 AC50-500V UH AC24V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053643\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V UH AC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053643\u003c\/strong\u003e (type BA9054\/010 AC50-500V UH AC24V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053643\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V UH AC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V UH AC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053643 (BA9054\/010 AC50-500V UH AC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500V UH AC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V UH AC24V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082240349,"sku":"0053643","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-uh-ac48v-0053644","title":"DOLD BA9054\/010 AC50-500V UH AC48V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053644\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V UH AC48V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053644\u003c\/strong\u003e (type BA9054\/010 AC50-500V UH AC48V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053644\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V UH AC48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V UH AC48V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V UH AC48V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053644 (BA9054\/010 AC50-500V UH AC48V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500V UH AC48V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V UH AC48V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V UH AC48V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V UH AC48V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082338653,"sku":"0053644","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-uh-ac110v-0053645","title":"DOLD BA9054\/010 AC50-500V UH AC110V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053645\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V UH AC110V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053645\u003c\/strong\u003e (type BA9054\/010 AC50-500V UH AC110V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053645\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V UH AC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V UH AC110V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053645 (BA9054\/010 AC50-500V UH AC110V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500V UH AC110V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V UH AC110V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082371421,"sku":"0053645","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-uh-ac127v-0053646","title":"DOLD BA9054\/010 AC50-500V UH AC127V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053646\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V UH AC127V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053646\u003c\/strong\u003e (type BA9054\/010 AC50-500V UH AC127V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 127 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053646\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V UH AC127V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V UH AC127V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053646 (BA9054\/010 AC50-500V UH AC127V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500V UH AC127V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V UH AC127V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082404189,"sku":"0053646","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-uh-ac230v-0053647","title":"DOLD BA9054\/010 AC50-500V UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053647\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053647\u003c\/strong\u003e (type BA9054\/010 AC50-500V UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053647 (BA9054\/010 AC50-500V UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500V UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082568029,"sku":"0053647","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-uh-ac240v-0053648","title":"DOLD BA9054\/010 AC50-500V UH AC240V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053648\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V UH AC240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053648\u003c\/strong\u003e (type BA9054\/010 AC50-500V UH AC240V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053648\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V UH AC240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V UH AC240V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053648 (BA9054\/010 AC50-500V UH AC240V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500V UH AC240V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V UH AC240V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V UH AC240V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082600797,"sku":"0053648","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-uh-ac-dc24-80v-0053649","title":"DOLD BA9054\/010 AC50-500V UH AC\/DC24-80V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053649\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V UH AC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053649\u003c\/strong\u003e (type BA9054\/010 AC50-500V UH AC\/DC24-80V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053649\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V UH AC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V UH AC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053649 (BA9054\/010 AC50-500V UH AC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC50-500V UH AC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V UH AC\/DC24-80V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V UH AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082633565,"sku":"0053649","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac50-500v-ac-dc80-230v-0053650","title":"DOLD BA9054\/010 AC50-500V AC\/DC80-230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053650\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC50-500V AC\/DC80-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053650\u003c\/strong\u003e (type BA9054\/010 AC50-500V AC\/DC80-230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 80 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 50 - 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC50-500V AC\/DC80-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC50-500V AC\/DC80-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC50-500V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053650 (BA9054\/010 AC50-500V AC\/DC80-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9054\/010 AC50-500V AC\/DC80-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC50-500V AC\/DC80-230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC50-500V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC50-500V AC\/DC80-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082666333,"sku":"0053650","price":212.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac15-150mv-uh-ac24v-0053651","title":"DOLD BA9054\/010 AC15-150MV UH AC24V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053651\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC15-150MV UH AC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053651\u003c\/strong\u003e (type BA9054\/010 AC15-150MV UH AC24V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 15 - 150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC15-150MV UH AC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC15-150MV UH AC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC15-150MV UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053651 (BA9054\/010 AC15-150MV UH AC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC15-150MV UH AC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC15-150MV UH AC24V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC15-150MV UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC15-150MV UH AC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082699101,"sku":"0053651","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac15-150mv-uh-ac110v-0053652","title":"DOLD BA9054\/010 AC15-150MV UH AC110V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053652\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC15-150MV UH AC110V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053652\u003c\/strong\u003e (type BA9054\/010 AC15-150MV UH AC110V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 15 - 150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC15-150MV UH AC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC15-150MV UH AC110V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC15-150MV UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053652 (BA9054\/010 AC15-150MV UH AC110V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC15-150MV UH AC110V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC15-150MV UH AC110V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC15-150MV UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC15-150MV UH AC110V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082731869,"sku":"0053652","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac15-150mv-uh-ac127v-0053653","title":"DOLD BA9054\/010 AC15-150MV UH AC127V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC15-150MV UH AC127V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053653\u003c\/strong\u003e (type BA9054\/010 AC15-150MV UH AC127V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 127 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 15 - 150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053653\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC15-150MV UH AC127V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC15-150MV UH AC127V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC15-150MV UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053653 (BA9054\/010 AC15-150MV UH AC127V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC15-150MV UH AC127V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC15-150MV UH AC127V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC15-150MV UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC15-150MV UH AC127V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082797405,"sku":"0053653","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"},{"product_id":"dold-ba9054-010-ac15-150mv-uh-ac230v-0053654","title":"DOLD BA9054\/010 AC15-150MV UH AC230V voltage relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053654\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9054\/010 AC15-150MV UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9054 – voltage relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053654\u003c\/strong\u003e (type BA9054\/010 AC15-150MV UH AC230V) belongs to the “BA 9054” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9054 voltage relay from the VARIMETER series monitors 1-phase DC or AC networks (\u003cstrong\u003eeach with 1 measuring range in AC and DC\u003c\/strong\u003e). The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection against device destruction caused by overvoltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC voltages\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 15 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 15 - 150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOvervoltage relay. Open-circuit principle. Switching delay at setting value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9054” product family comprises 318 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 20 s; 1 - 100 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 80 V; AC 230 V; AC\/DC 80 - 230 V; AC 110 V; AC 240 V; AC 24 V; AC 42 V; AC 115 V and others (12 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e DC 1 - 10 V; AC 70 - 700 V; AC 0.5 - 5 V; AC 15 - 150 mV; AC 50 - 500 mV; AC 1 - 10 V; AC 5 - 50 V; AC 25 - 250 V and others (15 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 30 s; 0 - 100 s; 0 - 2 s; 0 - 60 s; 20 s; 0 - 300 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9054\/010 AC15-150MV UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9054\/010 AC15-150MV UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9054\/010 AC15-150MV UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053654 (BA9054\/010 AC15-150MV UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is BA9054\/010 AC15-150MV UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9054\/010 AC15-150MV UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9054\/010 AC15-150MV UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9054\/010 AC15-150MV UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9054 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1b\/27\/d4\/1746608138\/BA9054_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9054 (PDF, 389.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2d\/09\/be\/1780410218\/BA9054.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9054 (ZIP, 288.35 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403082830173,"sku":"0053654","price":166.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9054.jpg?v=1793922129"}],"url":"https:\/\/www.iam24.de\/en\/collections\/dold-ba-9054.oembed?page=5","provider":"IAM24","version":"1.0","type":"link"}