{"title":"DOLD IL 9171 measuring relay for voltage monitoring","description":"\u003cp\u003eThe DOLD series \u003cstrong\u003eIL 9171\u003c\/strong\u003e (also IL9171) comprises 55 versions at IAM24 – mainly measuring relays for voltage monitoring. The variants differ mainly in supply voltage, measuring or setting range and contact configuration. All devices are genuine products from E. DOLD \u0026amp; Söhne; the type and DOLD article number are shown on every product page.\u003c\/p\u003e\u003c!--iam24-serie--\u003e\u003ch2\u003eDOLD IL 9171: versions at a glance\u003c\/h2\u003e\u003cp\u003eSpellings: \u003cstrong\u003eIL 9171\u003c\/strong\u003e · IL9171 · IL-9171. Each version has its own seven-digit DOLD article number (e.g. 0049402), which identifies the device unambiguously.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left\"\u003eType\u003c\/th\u003e\n\u003cth style=\"text-align:left\"\u003eVersions\u003c\/th\u003e\n\u003cth style=\"text-align:left\"\u003eExample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/030\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-030-3-nac400-230v-0-5-20s-0050170\"\u003e3\/NAC400\/230V 0.5-20S undervoltage relay, 3-phase\u003c\/a\u003e (0050170)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/031\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-031-3ac400v-0-55-1-05un-0050133\"\u003e3AC400V 0.55-1,05UN undervoltage relay, 3-phase\u003c\/a\u003e (0050133)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/001\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-001-3ac100v-0-55-1-05un-0051082\"\u003e3AC100V 0.55-1,05UN undervoltage relay, 3-phase\u003c\/a\u003e (0051082)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/201\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-201-3ac400v-0-7un-0049404\"\u003e3AC400V 0,7UN undervoltage relay, 3-phase\u003c\/a\u003e (0049404)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/041\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-041-3ac400v-0-55-1-05un-0049784\"\u003e3AC400V 0.55-1,05UN undervoltage relay, 3-phase\u003c\/a\u003e (0049784)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-3-n-ac400-230v-55-1-05un-0050823\"\u003e3\/N AC400\/230V ,55-1,05UN undervoltage relay, 3-phase\u003c\/a\u003e (0050823)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/240\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-240-3-n-ac400-230v-0-85un-0051969\"\u003e3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase\u003c\/a\u003e (0051969)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/231\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-231-3ac400v-0-7un-0053319\"\u003e3AC400V 0,7UN undervoltage relay, 3-phase\u003c\/a\u003e (0053319)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/200\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-200-3-n-ac400-230v-0-7un-0049402\"\u003e3\/N AC400\/230V 0,7UN undervoltage relay, 3-phase\u003c\/a\u003e (0049402)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/040\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-040-3-nac400-230v-0-5-20s-0050376\"\u003e3\/NAC400\/230V 0.5-20S undervoltage relay, 3-phase\u003c\/a\u003e (0050376)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/230\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-230-3-n-ac400-230v-0-85un-0052062\"\u003e3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase\u003c\/a\u003e (0052062)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIL 9171.12\/241\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en\/products\/dold-il9171-12-241-3ac400v-0-7un-0053991\"\u003e3AC400V 0,7UN undervoltage relay, 3-phase\u003c\/a\u003e (0053991)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eCommon supply or measuring voltages in this series:\u003c\/strong\u003e AC400\/230V (9), AC110\/63V (4), AC415\/240V (1), AC100\/57V (1), AC500\/290V (1), AC440\/254V (1).\u003c\/p\u003e\u003ch3\u003eHow to find the right version\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eSelect the type suffix (“Type” column); it is shown on the rating plate of the existing device.\u003c\/li\u003e\n\u003cli\u003eCompare the measuring or setting range and the supply voltage – both are stated in the product title.\u003c\/li\u003e\n\u003cli\u003eTo be sure, compare the DOLD article number and check the data sheet on the product page.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eCan’t find your version? \u003ca href=\"\/en\/pages\/individuelles-angebot\"\u003eRequest an individual quotation\u003c\/a\u003e – also for larger quantities.\u003c\/p\u003e\u003cp\u003eMore from this area: \u003ca href=\"\/en\/collections\/dold-messrelais-zur-spannungsueberwachung\"\u003eDOLD measuring relays for voltage monitoring\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dold#baureihen\"\u003eAll DOLD series A–Z\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"dold-il9171-12-200-3-n-ac400-230v-0-7un-0049402","title":"DOLD IL9171.12\/200 3\/N AC400\/230V 0,7UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049402\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/200 3\/N AC400\/230V 0,7UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049402\u003c\/strong\u003e (type IL9171.12\/200 3\/N AC400\/230V 0,7UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.7 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/200 3\/N AC400\/230V 0,7UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/200 3\/N AC400\/230V 0,7UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/200 3\/N AC400\/230V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049402 (IL9171.12\/200 3\/N AC400\/230V 0,7UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/200 3\/N AC400\/230V 0,7UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/200 3\/N AC400\/230V 0,7UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/200 3\/N AC400\/230V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/200 3\/N AC400\/230V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401625669981,"sku":"0049402","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-200-3-n-ac400-230v-0-85un-0049403","title":"DOLD IL9171.12\/200 3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049403\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/200 3\/N AC400\/230V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049403\u003c\/strong\u003e (type IL9171.12\/200 3\/N AC400\/230V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/200 3\/N AC400\/230V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/200 3\/N AC400\/230V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/200 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049403 (IL9171.12\/200 3\/N AC400\/230V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/200 3\/N AC400\/230V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/200 3\/N AC400\/230V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/200 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/200 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401625702749,"sku":"0049403","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-201-3ac400v-0-7un-0049404","title":"DOLD IL9171.12\/201 3AC400V 0,7UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049404\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/201 3AC400V 0,7UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049404\u003c\/strong\u003e (type IL9171.12\/201 3AC400V 0,7UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.7 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/201 3AC400V 0,7UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/201 3AC400V 0,7UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/201 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049404 (IL9171.12\/201 3AC400V 0,7UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/201 3AC400V 0,7UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/201 3AC400V 0,7UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/201 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/201 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401625768285,"sku":"0049404","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-201-3ac400v-0-85un-0049405","title":"DOLD IL9171.12\/201 3AC400V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049405\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/201 3AC400V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049405\u003c\/strong\u003e (type IL9171.12\/201 3AC400V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/201 3AC400V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/201 3AC400V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/201 3AC400V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049405 (IL9171.12\/201 3AC400V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/201 3AC400V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/201 3AC400V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/201 3AC400V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/201 3AC400V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401625801053,"sku":"0049405","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-041-3ac400v-0-55-1-05un-0049784","title":"DOLD IL9171.12\/041 3AC400V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049784\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/041 3AC400V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049784\u003c\/strong\u003e (type IL9171.12\/041 3AC400V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t2. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049784\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/041 3AC400V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/041 3AC400V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/041 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049784 (IL9171.12\/041 3AC400V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/041 3AC400V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/041 3AC400V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/041 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/041 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401641202013,"sku":"0049784","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac400v-0-55-1-05un-0050133","title":"DOLD IL9171.12\/031 3AC400V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0050133\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC400V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0050133\u003c\/strong\u003e (type IL9171.12\/031 3AC400V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0050133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC400V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC400V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0050133 (IL9171.12\/031 3AC400V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC400V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC400V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401654702429,"sku":"0050133","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-nac400-230v-0-5-20s-0050170","title":"DOLD IL9171.12\/030 3\/NAC400\/230V 0.5-20S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0050170\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/NAC400\/230V 0.5-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0050170\u003c\/strong\u003e (type IL9171.12\/030 3\/NAC400\/230V 0.5-20S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0050170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/NAC400\/230V 0.5-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/NAC400\/230V 0.5-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/NAC400\/230V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0050170 (IL9171.12\/030 3\/NAC400\/230V 0.5-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/030 3\/NAC400\/230V 0.5-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/NAC400\/230V 0.5-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/NAC400\/230V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/NAC400\/230V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401655062877,"sku":"0050170","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-040-3-nac400-230v-0-5-20s-0050376","title":"DOLD IL9171.12\/040 3\/NAC400\/230V 0.5-20S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0050376\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/040 3\/NAC400\/230V 0.5-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0050376\u003c\/strong\u003e (type IL9171.12\/040 3\/NAC400\/230V 0.5-20S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t2. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0050376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/040 3\/NAC400\/230V 0.5-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/040 3\/NAC400\/230V 0.5-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/040 3\/NAC400\/230V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0050376 (IL9171.12\/040 3\/NAC400\/230V 0.5-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/040 3\/NAC400\/230V 0.5-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/040 3\/NAC400\/230V 0.5-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/040 3\/NAC400\/230V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/040 3\/NAC400\/230V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401659847005,"sku":"0050376","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-3-n-ac400-230v-55-1-05un-0050823","title":"DOLD IL9171.12 3\/N AC400\/230V ,55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0050823\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12 3\/N AC400\/230V ,55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0050823\u003c\/strong\u003e (type IL9171.12 3\/N AC400\/230V ,55-1,05UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0050823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12 3\/N AC400\/230V ,55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12 3\/N AC400\/230V ,55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12 3\/N AC400\/230V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0050823 (IL9171.12 3\/N AC400\/230V ,55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12 3\/N AC400\/230V ,55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12 3\/N AC400\/230V ,55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12 3\/N AC400\/230V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12 3\/N AC400\/230V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401670005085,"sku":"0050823","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-001-3ac100v-0-55-1-05un-0051082","title":"DOLD IL9171.12\/001 3AC100V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051082\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/001 3AC100V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051082\u003c\/strong\u003e (type IL9171.12\/001 3AC100V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/001 3AC100V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/001 3AC100V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/001 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051082 (IL9171.12\/001 3AC100V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/001 3AC100V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/001 3AC100V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/001 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/001 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401673904477,"sku":"0051082","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac110v-0-55-1-05un-0051247","title":"DOLD IL9171.12\/031 3AC110V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051247\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC110V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051247\u003c\/strong\u003e (type IL9171.12\/031 3AC110V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC110V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC110V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051247 (IL9171.12\/031 3AC110V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC110V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC110V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401677640029,"sku":"0051247","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-001-3ac400v-0-55-1-05un-0051587","title":"DOLD IL9171.12\/001 3AC400V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051587\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/001 3AC400V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051587\u003c\/strong\u003e (type IL9171.12\/001 3AC400V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051587\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/001 3AC400V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/001 3AC400V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/001 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051587 (IL9171.12\/001 3AC400V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/001 3AC400V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/001 3AC400V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/001 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/001 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401682784605,"sku":"0051587","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-n-ac400-230v-2-200s-0051734","title":"DOLD IL9171.12\/030 3\/N AC400\/230V 2-200S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051734\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/N AC400\/230V 2-200S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051734\u003c\/strong\u003e (type IL9171.12\/030 3\/N AC400\/230V 2-200S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/N AC400\/230V 2-200S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/N AC400\/230V 2-200S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/N AC400\/230V 2-200S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051734 (IL9171.12\/030 3\/N AC400\/230V 2-200S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/030 3\/N AC400\/230V 2-200S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/N AC400\/230V 2-200S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/N AC400\/230V 2-200S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/N AC400\/230V 2-200S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401688158557,"sku":"0051734","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-041-3ac400v-0-55-1-05un-0051943","title":"DOLD IL9171.12\/041 3AC400V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051943\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/041 3AC400V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051943\u003c\/strong\u003e (type IL9171.12\/041 3AC400V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t2. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/041 3AC400V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/041 3AC400V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/041 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051943 (IL9171.12\/041 3AC400V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/041 3AC400V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/041 3AC400V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/041 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/041 3AC400V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401690616157,"sku":"0051943","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-240-3-n-ac400-230v-0-85un-0051969","title":"DOLD IL9171.12\/240 3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051969\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051969\u003c\/strong\u003e (type IL9171.12\/240 3\/N AC400\/230V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t2. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051969 (IL9171.12\/240 3\/N AC400\/230V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/240 3\/N AC400\/230V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/240 3\/N AC400\/230V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401691009373,"sku":"0051969","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-230-3-n-ac400-230v-0-85un-0052062","title":"DOLD IL9171.12\/230 3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0052062\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/230 3\/N AC400\/230V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0052062\u003c\/strong\u003e (type IL9171.12\/230 3\/N AC400\/230V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0052062\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/230 3\/N AC400\/230V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/230 3\/N AC400\/230V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/230 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0052062 (IL9171.12\/230 3\/N AC400\/230V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/230 3\/N AC400\/230V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/230 3\/N AC400\/230V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/230 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/230 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401692418397,"sku":"0052062","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-240-3-n-ac400-230v-0-85un-0052079","title":"DOLD IL9171.12\/240 3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0052079\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0052079\u003c\/strong\u003e (type IL9171.12\/240 3\/N AC400\/230V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t2. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0052079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0052079 (IL9171.12\/240 3\/N AC400\/230V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/240 3\/N AC400\/230V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/240 3\/N AC400\/230V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401694810461,"sku":"0052079","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-041-3ac230v-0-55-1-05un-0052707","title":"DOLD IL9171.12\/041 3AC230V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0052707\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/041 3AC230V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0052707\u003c\/strong\u003e (type IL9171.12\/041 3AC230V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t2. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0052707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/041 3AC230V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/041 3AC230V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/041 3AC230V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0052707 (IL9171.12\/041 3AC230V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/041 3AC230V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/041 3AC230V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/041 3AC230V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/041 3AC230V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401710309725,"sku":"0052707","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-231-3ac400v-0-7un-0053319","title":"DOLD IL9171.12\/231 3AC400V 0,7UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053319\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/231 3AC400V 0,7UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053319\u003c\/strong\u003e (type IL9171.12\/231 3AC400V 0,7UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.7 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/231 3AC400V 0,7UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/231 3AC400V 0,7UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/231 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053319 (IL9171.12\/231 3AC400V 0,7UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/231 3AC400V 0,7UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/231 3AC400V 0,7UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/231 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/231 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403072967005,"sku":"0053319","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-231-3ac500v-0-7un-0053512","title":"DOLD IL9171.12\/231 3AC500V 0,7UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053512\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/231 3AC500V 0,7UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053512\u003c\/strong\u003e (type IL9171.12\/231 3AC500V 0,7UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.7 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/231 3AC500V 0,7UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/231 3AC500V 0,7UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/231 3AC500V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053512 (IL9171.12\/231 3AC500V 0,7UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/231 3AC500V 0,7UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/231 3AC500V 0,7UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/231 3AC500V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/231 3AC500V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403078439261,"sku":"0053512","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-041-3ac100v-0-55-1-05un-0053832","title":"DOLD IL9171.12\/041 3AC100V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053832\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/041 3AC100V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053832\u003c\/strong\u003e (type IL9171.12\/041 3AC100V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t2. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053832\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/041 3AC100V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/041 3AC100V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/041 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053832 (IL9171.12\/041 3AC100V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/041 3AC100V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/041 3AC100V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/041 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/041 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403089940829,"sku":"0053832","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-241-3ac400v-0-7un-0053991","title":"DOLD IL9171.12\/241 3AC400V 0,7UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053991\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/241 3AC400V 0,7UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053991\u003c\/strong\u003e (type IL9171.12\/241 3AC400V 0,7UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.7 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t2. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/241 3AC400V 0,7UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/241 3AC400V 0,7UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/241 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053991 (IL9171.12\/241 3AC400V 0,7UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/241 3AC400V 0,7UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/241 3AC400V 0,7UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/241 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/241 3AC400V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403092103517,"sku":"0053991","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-001-3ac127v-0-55-1-05un-0054685","title":"DOLD IL9171.12\/001 3AC127V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0054685\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/001 3AC127V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0054685\u003c\/strong\u003e (type IL9171.12\/001 3AC127V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 127 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0054685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/001 3AC127V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/001 3AC127V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/001 3AC127V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0054685 (IL9171.12\/001 3AC127V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/001 3AC127V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/001 3AC127V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/001 3AC127V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/001 3AC127V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403122708829,"sku":"0054685","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-001-3ac440v-0-55-1-05un-0054778","title":"DOLD IL9171.12\/001 3AC440V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0054778\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/001 3AC440V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0054778\u003c\/strong\u003e (type IL9171.12\/001 3AC440V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0054778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/001 3AC440V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/001 3AC440V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/001 3AC440V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0054778 (IL9171.12\/001 3AC440V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/001 3AC440V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/001 3AC440V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/001 3AC440V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/001 3AC440V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403132997981,"sku":"0054778","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac500v-0-55-1-05un-0054796","title":"DOLD IL9171.12\/031 3AC500V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0054796\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC500V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0054796\u003c\/strong\u003e (type IL9171.12\/031 3AC500V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0054796\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC500V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC500V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0054796 (IL9171.12\/031 3AC500V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC500V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC500V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403133292893,"sku":"0054796","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-001-3ac220v-0-55-1-05un-0054989","title":"DOLD IL9171.12\/001 3AC220V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0054989\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/001 3AC220V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0054989\u003c\/strong\u003e (type IL9171.12\/001 3AC220V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0054989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/001 3AC220V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/001 3AC220V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/001 3AC220V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0054989 (IL9171.12\/001 3AC220V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/001 3AC220V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/001 3AC220V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/001 3AC220V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/001 3AC220V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403135455581,"sku":"0054989","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-041-3ac500v-0-55-1-05un-0055170","title":"DOLD IL9171.12\/041 3AC500V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0055170\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/041 3AC500V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0055170\u003c\/strong\u003e (type IL9171.12\/041 3AC500V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t2. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0055170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/041 3AC500V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/041 3AC500V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/041 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0055170 (IL9171.12\/041 3AC500V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/041 3AC500V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/041 3AC500V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/041 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/041 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403137323357,"sku":"0055170","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-n-ac110-63v-0-5-20s-0055384","title":"DOLD IL9171.12\/030 3\/N AC110\/63V 0.5-20S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0055384\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/N AC110\/63V 0.5-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0055384\u003c\/strong\u003e (type IL9171.12\/030 3\/N AC110\/63V 0.5-20S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 110 \/ 63 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0055384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/N AC110\/63V 0.5-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/N AC110\/63V 0.5-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/N AC110\/63V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0055384 (IL9171.12\/030 3\/N AC110\/63V 0.5-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/030 3\/N AC110\/63V 0.5-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/N AC110\/63V 0.5-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/N AC110\/63V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/N AC110\/63V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403139158365,"sku":"0055384","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-001-3ac500v-0-55-1-05un-0055516","title":"DOLD IL9171.12\/001 3AC500V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0055516\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/001 3AC500V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0055516\u003c\/strong\u003e (type IL9171.12\/001 3AC500V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0055516\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/001 3AC500V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/001 3AC500V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/001 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0055516 (IL9171.12\/001 3AC500V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/001 3AC500V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/001 3AC500V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/001 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/001 3AC500V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403140534621,"sku":"0055516","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac480v-0-55-1-05un-0056098","title":"DOLD IL9171.12\/031 3AC480V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0056098\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC480V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0056098\u003c\/strong\u003e (type IL9171.12\/031 3AC480V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0056098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC480V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC480V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC480V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0056098 (IL9171.12\/031 3AC480V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC480V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC480V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC480V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC480V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403153215837,"sku":"0056098","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-240-3-n-ac400-230v-0-85un-0056426","title":"DOLD IL9171.12\/240 3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0056426\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0056426\u003c\/strong\u003e (type IL9171.12\/240 3\/N AC400\/230V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t2. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0056426\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/240 3\/N AC400\/230V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0056426 (IL9171.12\/240 3\/N AC400\/230V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/240 3\/N AC400\/230V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/240 3\/N AC400\/230V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/240 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403155804509,"sku":"0056426","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-201-3ac230v-0-7un-0056473","title":"DOLD IL9171.12\/201 3AC230V 0,7UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0056473\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/201 3AC230V 0,7UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0056473\u003c\/strong\u003e (type IL9171.12\/201 3AC230V 0,7UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.7 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0056473\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/201 3AC230V 0,7UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/201 3AC230V 0,7UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/201 3AC230V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0056473 (IL9171.12\/201 3AC230V 0,7UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/201 3AC230V 0,7UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/201 3AC230V 0,7UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/201 3AC230V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/201 3AC230V 0,7UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403156656477,"sku":"0056473","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-3-n-ac415-240v-55-1-05un-0056683","title":"DOLD IL9171.12 3\/N AC415\/240V ,55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0056683\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12 3\/N AC415\/240V ,55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0056683\u003c\/strong\u003e (type IL9171.12 3\/N AC415\/240V ,55-1,05UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 415 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0056683\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12 3\/N AC415\/240V ,55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12 3\/N AC415\/240V ,55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12 3\/N AC415\/240V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0056683 (IL9171.12 3\/N AC415\/240V ,55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12 3\/N AC415\/240V ,55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12 3\/N AC415\/240V ,55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12 3\/N AC415\/240V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12 3\/N AC415\/240V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403880272221,"sku":"0056683","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac100v-0-55-1-05un-0057456","title":"DOLD IL9171.12\/031 3AC100V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0057456\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC100V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0057456\u003c\/strong\u003e (type IL9171.12\/031 3AC100V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0057456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC100V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC100V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0057456 (IL9171.12\/031 3AC100V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC100V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC100V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC100V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403958456669,"sku":"0057456","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-001-3ac110v-0-55-1-05un-0057695","title":"DOLD IL9171.12\/001 3AC110V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0057695\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/001 3AC110V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0057695\u003c\/strong\u003e (type IL9171.12\/001 3AC110V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0057695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/001 3AC110V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/001 3AC110V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/001 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0057695 (IL9171.12\/001 3AC110V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/001 3AC110V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/001 3AC110V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/001 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/001 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403960062301,"sku":"0057695","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-041-3ac110v-0-55-1-05un-0058307","title":"DOLD IL9171.12\/041 3AC110V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0058307\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/041 3AC110V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0058307\u003c\/strong\u003e (type IL9171.12\/041 3AC110V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t2. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0058307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/041 3AC110V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/041 3AC110V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/041 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0058307 (IL9171.12\/041 3AC110V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/041 3AC110V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/041 3AC110V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/041 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/041 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403974021469,"sku":"0058307","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-3-n-ac110-63v-0-55-1-05un-0058506","title":"DOLD IL9171.12 3\/N AC110\/63V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0058506\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12 3\/N AC110\/63V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0058506\u003c\/strong\u003e (type IL9171.12 3\/N AC110\/63V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 110 \/ 63 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0058506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12 3\/N AC110\/63V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12 3\/N AC110\/63V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12 3\/N AC110\/63V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0058506 (IL9171.12 3\/N AC110\/63V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12 3\/N AC110\/63V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12 3\/N AC110\/63V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12 3\/N AC110\/63V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12 3\/N AC110\/63V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403997974877,"sku":"0058506","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-nac415-240v-0-5-20s-0058952","title":"DOLD IL9171.12\/030 3\/NAC415\/240V 0.5-20S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0058952\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/NAC415\/240V 0.5-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0058952\u003c\/strong\u003e (type IL9171.12\/030 3\/NAC415\/240V 0.5-20S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 415 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0058952\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/NAC415\/240V 0.5-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/NAC415\/240V 0.5-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/NAC415\/240V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0058952 (IL9171.12\/030 3\/NAC415\/240V 0.5-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/030 3\/NAC415\/240V 0.5-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/NAC415\/240V 0.5-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/NAC415\/240V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/NAC415\/240V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404039065949,"sku":"0058952","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-201-3ac110v-0-85un-0059098","title":"DOLD IL9171.12\/201 3AC110V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0059098\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/201 3AC110V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0059098\u003c\/strong\u003e (type IL9171.12\/201 3AC110V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0059098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/201 3AC110V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/201 3AC110V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/201 3AC110V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0059098 (IL9171.12\/201 3AC110V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/201 3AC110V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/201 3AC110V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/201 3AC110V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/201 3AC110V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404043129181,"sku":"0059098","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac220v-0-55-1-05un-0059285","title":"DOLD IL9171.12\/031 3AC220V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0059285\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC220V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0059285\u003c\/strong\u003e (type IL9171.12\/031 3AC220V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0059285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC220V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC220V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC220V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0059285 (IL9171.12\/031 3AC220V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC220V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC220V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC220V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC220V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404053811549,"sku":"0059285","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-801-3-n-ac400-230v-0-85un-0060545","title":"DOLD IL9171.12\/801 3\/N AC400\/230V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0060545\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/801 3\/N AC400\/230V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0060545\u003c\/strong\u003e (type IL9171.12\/801 3\/N AC400\/230V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 400 \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value. For switching small loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0060545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/801 3\/N AC400\/230V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/801 3\/N AC400\/230V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/801 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0060545 (IL9171.12\/801 3\/N AC400\/230V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/801 3\/N AC400\/230V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/801 3\/N AC400\/230V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/801 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/801 3\/N AC400\/230V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404081467741,"sku":"0060545","price":98.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-201-3ac500v-0-85un-0060830","title":"DOLD IL9171.12\/201 3AC500V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0060830\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/201 3AC500V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0060830\u003c\/strong\u003e (type IL9171.12\/201 3AC500V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. Without time delay. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0060830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/201 3AC500V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/201 3AC500V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/201 3AC500V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0060830 (IL9171.12\/201 3AC500V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/201 3AC500V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/201 3AC500V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/201 3AC500V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/201 3AC500V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404083990877,"sku":"0060830","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-n-ac100-57v-0-5-20s-0060859","title":"DOLD IL9171.12\/030 3\/N AC100\/57V 0.5-20S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0060859\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/N AC100\/57V 0.5-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0060859\u003c\/strong\u003e (type IL9171.12\/030 3\/N AC100\/57V 0.5-20S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 100 \/ 57 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0060859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/N AC100\/57V 0.5-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/N AC100\/57V 0.5-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/N AC100\/57V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0060859 (IL9171.12\/030 3\/N AC100\/57V 0.5-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/030 3\/N AC100\/57V 0.5-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/N AC100\/57V 0.5-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/N AC100\/57V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/N AC100\/57V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404084154717,"sku":"0060859","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-231-3ac400v-0-85un-0061720","title":"DOLD IL9171.12\/231 3AC400V 0,85UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0061720\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/231 3AC400V 0,85UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0061720\u003c\/strong\u003e (type IL9171.12\/231 3AC400V 0,85UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.85 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Fixed response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0061720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/231 3AC400V 0,85UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/231 3AC400V 0,85UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/231 3AC400V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0061720 (IL9171.12\/231 3AC400V 0,85UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/231 3AC400V 0,85UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/231 3AC400V 0,85UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/231 3AC400V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/231 3AC400V 0,85UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404104765789,"sku":"0061720","price":92.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac440v-0-55-1-05un-0061940","title":"DOLD IL9171.12\/031 3AC440V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0061940\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC440V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0061940\u003c\/strong\u003e (type IL9171.12\/031 3AC440V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0061940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC440V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC440V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC440V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0061940 (IL9171.12\/031 3AC440V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC440V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC440V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC440V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC440V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404107714909,"sku":"0061940","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-3-n-ac500-290v-55-1-05un-0062579","title":"DOLD IL9171.12 3\/N AC500\/290V ,55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0062579\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12 3\/N AC500\/290V ,55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0062579\u003c\/strong\u003e (type IL9171.12 3\/N AC500\/290V ,55-1,05UN) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 500 \/ 290 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. Without time delay. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0062579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12 3\/N AC500\/290V ,55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12 3\/N AC500\/290V ,55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12 3\/N AC500\/290V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0062579 (IL9171.12 3\/N AC500\/290V ,55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12 3\/N AC500\/290V ,55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12 3\/N AC500\/290V ,55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12 3\/N AC500\/290V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12 3\/N AC500\/290V ,55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407574045021,"sku":"0062579","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-n-ac110-63v-0-1-20m-0062888","title":"DOLD IL9171.12\/030 3\/N AC110\/63V 0.1-20M undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0062888\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/N AC110\/63V 0.1-20M\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0062888\u003c\/strong\u003e (type IL9171.12\/030 3\/N AC110\/63V 0.1-20M) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 110 \/ 63 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 20 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0062888\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/N AC110\/63V 0.1-20M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/N AC110\/63V 0.1-20M\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/N AC110\/63V 0.1-20M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0062888 (IL9171.12\/030 3\/N AC110\/63V 0.1-20M) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/030 3\/N AC110\/63V 0.1-20M sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/N AC110\/63V 0.1-20M is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/N AC110\/63V 0.1-20M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/N AC110\/63V 0.1-20M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407577715037,"sku":"0062888","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-nac220-127v-0-5-20s-0063310","title":"DOLD IL9171.12\/030 3\/NAC220\/127V 0.5-20S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0063310\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/NAC220\/127V 0.5-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0063310\u003c\/strong\u003e (type IL9171.12\/030 3\/NAC220\/127V 0.5-20S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 220 \/ 127 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0063310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/NAC220\/127V 0.5-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/NAC220\/127V 0.5-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/NAC220\/127V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0063310 (IL9171.12\/030 3\/NAC220\/127V 0.5-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/030 3\/NAC220\/127V 0.5-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/NAC220\/127V 0.5-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/NAC220\/127V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/NAC220\/127V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407590658397,"sku":"0063310","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-030-3-nac480-277v-0-5-20s-0063551","title":"DOLD IL9171.12\/030 3\/NAC480\/277V 0.5-20S undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0063551\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/030 3\/NAC480\/277V 0.5-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0063551\u003c\/strong\u003e (type IL9171.12\/030 3\/NAC480\/277V 0.5-20S) belongs to the “IL 9171” product family (monitoring technology – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\/N AC 480 \/ 277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0063551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/030 3\/NAC480\/277V 0.5-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/030 3\/NAC480\/277V 0.5-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/030 3\/NAC480\/277V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0063551 (IL9171.12\/030 3\/NAC480\/277V 0.5-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IL9171.12\/030 3\/NAC480\/277V 0.5-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/030 3\/NAC480\/277V 0.5-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/030 3\/NAC480\/277V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/030 3\/NAC480\/277V 0.5-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407594688861,"sku":"0063551","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"},{"product_id":"dold-il9171-12-031-3ac110v-0-55-1-05un-0063714","title":"DOLD IL9171.12\/031 3AC110V 0.55-1,05UN undervoltage relay, 3-phase","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0063714\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9171.12\/031 3AC110V 0.55-1,05UN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9171 – undervoltage relay, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0063714\u003c\/strong\u003e (type IL9171.12\/031 3AC110V 0.55-1,05UN) belongs to the “IL 9171” product family (monitoring technology range – measuring relays for voltage monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eMonitoring of three-phase networks for undervoltage. Mains monitoring and changeover to safety power supply or safety lighting according to DIN VDE 0100-710 or DIN VDE 0108.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of undervoltage in three-phase networks\u003c\/li\u003e\n\u003cli\u003eCan also be connected single-phase\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicator for contact position\u003c\/li\u003e\n\u003cli\u003ePhase sequence irrelevant\u003c\/li\u003e\n\u003cli\u003e1 or 2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eOptionally fixed or adjustable response value\u003c\/li\u003e\n\u003cli\u003eOptionally with phase sequence detection\u003c\/li\u003e\n\u003cli\u003eOptionally with or without neutral conductor connection\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t1 for fault message\u003c\/li\u003e\n\u003cli\u003eOptionally with time delay t2 for switching back to good state\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9171, SK 9171: 17.5 mm width I design: 59 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43 880 S design: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct IL 9171, SL 9171: 35 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.55 - 1.05 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 20 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout neutral conductor connection. Closed-circuit principle. With adjustable time t1. Adjustable response value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9171” product family comprises 55 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 0.7 Un; 0.85 Un; 0.55 - 1.05 Un\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3\/N AC 400 \/ 230 V; 3AC 400 V; 3AC 100 V; 3AC 110 V; 3AC 230 V; 3AC 500 V; 3AC 127 V; 3AC 440 V and others (18 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e None; 0.5 - 20 s; 2 - 200 s; 0.1 - 20 min; 1 - 20 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0063714\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9171.12\/031 3AC110V 0.55-1,05UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9171.12\/031 3AC110V 0.55-1,05UN\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9171.12\/031 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0063714 (IL9171.12\/031 3AC110V 0.55-1,05UN) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9171.12\/031 3AC110V 0.55-1,05UN sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9171.12\/031 3AC110V 0.55-1,05UN is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9171.12\/031 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for IL9171.12\/031 3AC110V 0.55-1,05UN?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the IL 9171 product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/03\/80\/4b\/1746608150\/IK9171_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9171, IL 9171, SK 9171, SL 9171 (PDF, 485.34 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2e\/0d\/88\/1780410182\/IK_IL9171.zip?ts=1784806129\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro IK \/ IL 9171 (ZIP, 193.5 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407596360029,"sku":"0063714","price":100.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9171.jpg?v=1793922085"}],"url":"https:\/\/www.iam24.de\/en\/collections\/dold-il-9171.oembed","provider":"IAM24","version":"1.0","type":"link"}