{"title":"DOLD IP 9277 over- and undercurrent relay","description":"\u003cp\u003eThe DOLD series \u003cstrong\u003eIP 9277\u003c\/strong\u003e (also IP9277) comprises 14 versions at IAM24 – mainly over- and undercurrent relays. The variants differ mainly in supply voltage, measuring or setting range and contact configuration. All devices are genuine products from E. DOLD \u0026amp; Söhne; the type and DOLD article number are shown on every product page.\u003c\/p\u003e\u003cp\u003eMore from this area: \u003ca href=\"\/en\/collections\/dold-messrelais-zur-stromueberwachung\"\u003eDOLD measuring relays for current monitoring\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dold#baureihen\"\u003eAll DOLD series A–Z\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"dold-ip9277-39-ac-dc24v-0-5-5a-0049307","title":"DOLD IP9277.39 AC\/DC24V 0.5-5A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049307\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC\/DC24V 0.5-5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049307\u003c\/strong\u003e (type IP9277.39 AC\/DC24V 0.5-5A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC\/DC24V 0.5-5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC\/DC24V 0.5-5A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC\/DC24V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049307 (IP9277.39 AC\/DC24V 0.5-5A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39 AC\/DC24V 0.5-5A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC\/DC24V 0.5-5A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC\/DC24V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401624785245,"sku":"0049307","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-ac220-240v-0-5-5a-0049308","title":"DOLD IP9277.39 AC220-240V 0.5-5A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049308\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC220-240V 0.5-5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049308\u003c\/strong\u003e (type IP9277.39 AC220-240V 0.5-5A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC220-240V 0.5-5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC220-240V 0.5-5A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC220-240V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049308 (IP9277.39 AC220-240V 0.5-5A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39 AC220-240V 0.5-5A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC220-240V 0.5-5A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC220-240V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401624850781,"sku":"0049308","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-002-ac220-240v-0-5-5a-0049891","title":"DOLD IP9277.39\/002 AC220-240V 0.5-5A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0049891\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39\/002 AC220-240V 0.5-5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0049891\u003c\/strong\u003e (type IP9277.39\/002 AC220-240V 0.5-5A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Undercurrent monitoring on the closed-circuit principle. Overcurrent monitoring on the open-circuit principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0049891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39\/002 AC220-240V 0.5-5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39\/002 AC220-240V 0.5-5A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39\/002 AC220-240V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0049891 (IP9277.39\/002 AC220-240V 0.5-5A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39\/002 AC220-240V 0.5-5A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39\/002 AC220-240V 0.5-5A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39\/002 AC220-240V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401645822301,"sku":"0049891","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-010-ac220-240v-0-5-5a-0050359","title":"DOLD IP9277.39\/010 AC220-240V 0.5-5A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0050359\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39\/010 AC220-240V 0.5-5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0050359\u003c\/strong\u003e (type IP9277.39\/010 AC220-240V 0.5-5A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-lock principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0050359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39\/010 AC220-240V 0.5-5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39\/010 AC220-240V 0.5-5A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39\/010 AC220-240V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0050359 (IP9277.39\/010 AC220-240V 0.5-5A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39\/010 AC220-240V 0.5-5A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39\/010 AC220-240V 0.5-5A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39\/010 AC220-240V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401659748701,"sku":"0050359","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-002-ac400-440v-0-5-5a-0050436","title":"DOLD IP9277.39\/002 AC400-440V 0.5-5A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0050436\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39\/002 AC400-440V 0.5-5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0050436\u003c\/strong\u003e (type IP9277.39\/002 AC400-440V 0.5-5A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 400 - 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Undercurrent monitoring on the closed-circuit principle. Overcurrent monitoring on the open-circuit principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0050436\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39\/002 AC400-440V 0.5-5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39\/002 AC400-440V 0.5-5A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39\/002 AC400-440V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0050436 (IP9277.39\/002 AC400-440V 0.5-5A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39\/002 AC400-440V 0.5-5A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39\/002 AC400-440V 0.5-5A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39\/002 AC400-440V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401661518173,"sku":"0050436","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-ac220-240v-1-10a-0051206","title":"DOLD IP9277.39 AC220-240V 1-10A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051206\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC220-240V 1-10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051206\u003c\/strong\u003e (type IP9277.39 AC220-240V 1-10A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC220-240V 1-10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC220-240V 1-10A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC220-240V 1-10A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051206 (IP9277.39 AC220-240V 1-10A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IP9277.39 AC220-240V 1-10A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC220-240V 1-10A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC220-240V 1-10A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401676001629,"sku":"0051206","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-002-ac220-240v-1-5-15a-0051326","title":"DOLD IP9277.39\/002 AC220-240V 1.5-15A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0051326\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39\/002 AC220-240V 1.5-15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0051326\u003c\/strong\u003e (type IP9277.39\/002 AC220-240V 1.5-15A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Undercurrent monitoring on the closed-circuit principle. Overcurrent monitoring on the open-circuit principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0051326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39\/002 AC220-240V 1.5-15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39\/002 AC220-240V 1.5-15A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39\/002 AC220-240V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0051326 (IP9277.39\/002 AC220-240V 1.5-15A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39\/002 AC220-240V 1.5-15A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39\/002 AC220-240V 1.5-15A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39\/002 AC220-240V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401679901021,"sku":"0051326","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-ac220-240v-0-1-1a-0053074","title":"DOLD IP9277.39 AC220-240V 0.1-1A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053074\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC220-240V 0.1-1A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053074\u003c\/strong\u003e (type IP9277.39 AC220-240V 0.1-1A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC220-240V 0.1-1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC220-240V 0.1-1A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC220-240V 0.1-1A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053074 (IP9277.39 AC220-240V 0.1-1A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39 AC220-240V 0.1-1A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC220-240V 0.1-1A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC220-240V 0.1-1A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403060482397,"sku":"0053074","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-010-ac220-240v-1-5-15a-0053082","title":"DOLD IP9277.39\/010 AC220-240V 1.5-15A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053082\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39\/010 AC220-240V 1.5-15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053082\u003c\/strong\u003e (type IP9277.39\/010 AC220-240V 1.5-15A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-lock principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39\/010 AC220-240V 1.5-15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39\/010 AC220-240V 1.5-15A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39\/010 AC220-240V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053082 (IP9277.39\/010 AC220-240V 1.5-15A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39\/010 AC220-240V 1.5-15A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39\/010 AC220-240V 1.5-15A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39\/010 AC220-240V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403060580701,"sku":"0053082","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-ac220-240v-1-5-15a-0053219","title":"DOLD IP9277.39 AC220-240V 1.5-15A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0053219\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC220-240V 1.5-15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0053219\u003c\/strong\u003e (type IP9277.39 AC220-240V 1.5-15A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0053219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC220-240V 1.5-15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC220-240V 1.5-15A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC220-240V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0053219 (IP9277.39 AC220-240V 1.5-15A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39 AC220-240V 1.5-15A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC220-240V 1.5-15A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC220-240V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403070640477,"sku":"0053219","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-ac400-440v-0-5-5a-0054433","title":"DOLD IP9277.39 AC400-440V 0.5-5A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0054433\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC400-440V 0.5-5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0054433\u003c\/strong\u003e (type IP9277.39 AC400-440V 0.5-5A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 400 - 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 - 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0054433\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC400-440V 0.5-5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC400-440V 0.5-5A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC400-440V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0054433 (IP9277.39 AC400-440V 0.5-5A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39 AC400-440V 0.5-5A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC400-440V 0.5-5A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC400-440V 0.5-5A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403104358749,"sku":"0054433","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-ac-dc24v-1-10a-0055730","title":"DOLD IP9277.39 AC\/DC24V 1-10A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0055730\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC\/DC24V 1-10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0055730\u003c\/strong\u003e (type IP9277.39 AC\/DC24V 1-10A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0055730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC\/DC24V 1-10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC\/DC24V 1-10A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC\/DC24V 1-10A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0055730 (IP9277.39 AC\/DC24V 1-10A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is IP9277.39 AC\/DC24V 1-10A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC\/DC24V 1-10A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC\/DC24V 1-10A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403143385437,"sku":"0055730","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-010-ac400-440v-1-5-15a-0059226","title":"DOLD IP9277.39\/010 AC400-440V 1.5-15A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0059226\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39\/010 AC400-440V 1.5-15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0059226\u003c\/strong\u003e (type IP9277.39\/010 AC400-440V 1.5-15A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 400 - 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-lock principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0059226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39\/010 AC400-440V 1.5-15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39\/010 AC400-440V 1.5-15A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39\/010 AC400-440V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0059226 (IP9277.39\/010 AC400-440V 1.5-15A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39\/010 AC400-440V 1.5-15A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39\/010 AC400-440V 1.5-15A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39\/010 AC400-440V 1.5-15A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404053090653,"sku":"0059226","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"},{"product_id":"dold-ip9277-39-ac-dc24v-0-1-1a-0065877","title":"DOLD IP9277.39 AC\/DC24V 0.1-1A overcurrent and undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065877\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IP9277.39 AC\/DC24V 0.1-1A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IP 9277 – overcurrent and undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065877\u003c\/strong\u003e (type IP9277.39 AC\/DC24V 0.1-1A) belongs to the “IP 9277” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and undercurrent monitoring in three-phase and single-phase AC networks.\u003c\/li\u003e\n\u003cli\u003eFor industrial and railway applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60 255-1\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277, SP 9277CT: 3-phase. IL 9277, SL 9277, SL 9277CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eDetection of overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 15 A\u003c\/li\u003e\n\u003cli\u003eWith integrated feed-through current transformer: from 0.5 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with 4 programmable measuring ranges\u003c\/li\u003e\n\u003cli\u003eAdjustable 0.1 ... 1 IN. Separate limit value setting for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis approx. 4 %\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with separately adjustable switching delays for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK status, overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277 with common output relay for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eIP 9277, SP 9277 with one output relay each for overcurrent and undercurrent\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43. 880 depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003cul\u003e\n\u003cli\u003eI design, e.g. IL _ _ _ _, in 61 mm\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SL _ _ _ _, in 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eIL 9277, SL 9277, SL 9277CT: 35 mm width. IP 9277, SP 9277, SP 9277CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3-phase current relay. Power-to-release principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IP 9277” product family comprises 14 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC 400 - 440 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.5 - 5 A; 1 - 10 A; 1.5 - 15 A; 0.1 - 1 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065877\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP9277.39 AC\/DC24V 0.1-1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IP9277.39 AC\/DC24V 0.1-1A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IP9277.39 AC\/DC24V 0.1-1A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065877 (IP9277.39 AC\/DC24V 0.1-1A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IP9277.39 AC\/DC24V 0.1-1A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP9277.39 AC\/DC24V 0.1-1A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IP9277.39 AC\/DC24V 0.1-1A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/da\/d1\/c7\/1746608183\/IL9277_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9277, IP 9277, SL 9277, SP 9277 (PDF, 1.03 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407681556829,"sku":"0065877","price":287.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IP9277.jpg?v=1793922086"}],"url":"https:\/\/www.iam24.de\/en\/collections\/dold-ip-9277.oembed","provider":"IAM24","version":"1.0","type":"link"}