{"title":"DOLD LK 5895 insulation monitor","description":"\u003cp\u003eThe DOLD series \u003cstrong\u003eLK 5895\u003c\/strong\u003e (also LK5895) comprises 10 versions at IAM24 – mainly insulation monitors. The variants differ mainly in supply voltage, measuring or setting range and contact configuration. All devices are genuine products from E. DOLD \u0026amp; Söhne; the type and DOLD article number are shown on every product page.\u003c\/p\u003e\u003cp\u003eMore from this area: \u003ca href=\"\/en\/collections\/dold-isolationswaechter\"\u003eDOLD insulation monitors\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dold#baureihen\"\u003eAll DOLD series A–Z\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"dold-lk5895-12-61-dc24v-1k-250k-20k-2m-0065216","title":"DOLD LK5895.12\/61 DC24V 1k-250k 20k-2M insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065216\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/61 DC24V 1k-250k 20k-2M\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065216\u003c\/strong\u003e (type LK5895.12\/61 DC24V 1k-250k 20k-2M) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). With analogue output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/61 DC24V 1k-250k 20k-2M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/61 DC24V 1k-250k 20k-2M\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/61 DC24V 1k-250k 20k-2M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065216 (LK5895.12\/61 DC24V 1k-250k 20k-2M) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/61 DC24V 1k-250k 20k-2M sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/61 DC24V 1k-250k 20k-2M is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/61 DC24V 1k-250k 20k-2M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/61 DC24V 1k-250k 20k-2M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407670907229,"sku":"0065216","price":1402.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-010-61-dc24v-1k-250k-0065217","title":"DOLD LK5895.12\/010\/61 DC24V 1k-250k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065217\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/010\/61 DC24V 1k-250k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065217\u003c\/strong\u003e (type LK5895.12\/010\/61 DC24V 1k-250k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Without analogue output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/010\/61 DC24V 1k-250k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/010\/61 DC24V 1k-250k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/010\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065217 (LK5895.12\/010\/61 DC24V 1k-250k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/010\/61 DC24V 1k-250k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/010\/61 DC24V 1k-250k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/010\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/010\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407670939997,"sku":"0065217","price":1328.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-011-61-dc24v-1k-250k-0065928","title":"DOLD LK5895.12\/011\/61 DC24V 1k-250k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065928\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/011\/61 DC24V 1k-250k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065928\u003c\/strong\u003e (type LK5895.12\/011\/61 DC24V 1k-250k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout wire break detection on L(+)\/L(-). Without analogue output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065928\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/011\/61 DC24V 1k-250k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/011\/61 DC24V 1k-250k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/011\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065928 (LK5895.12\/011\/61 DC24V 1k-250k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/011\/61 DC24V 1k-250k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/011\/61 DC24V 1k-250k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/011\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/011\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407683227997,"sku":"0065928","price":1328.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-010-61-dc24v-1k-15k-0067983","title":"DOLD LK5895.12\/010\/61 DC24V 1k-15k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0067983\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/010\/61 DC24V 1k-15k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0067983\u003c\/strong\u003e (type LK5895.12\/010\/61 DC24V 1k-15k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 15 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 18 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Without analogue output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0067983\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/010\/61 DC24V 1k-15k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/010\/61 DC24V 1k-15k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/010\/61 DC24V 1k-15k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0067983 (LK5895.12\/010\/61 DC24V 1k-15k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/010\/61 DC24V 1k-15k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/010\/61 DC24V 1k-15k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/010\/61 DC24V 1k-15k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/010\/61 DC24V 1k-15k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407717175645,"sku":"0067983","price":1328.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-020-dc24v-1k-250k-20k-2m-0068781","title":"DOLD LK5895.12\/020 DC24V 1k-250k 20k-2M insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068781\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/020 DC24V 1k-250k 20k-2M\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068781\u003c\/strong\u003e (type LK5895.12\/020 DC24V 1k-250k 20k-2M) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Without analogue output. With extended temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068781\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/020 DC24V 1k-250k 20k-2M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/020 DC24V 1k-250k 20k-2M\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/020 DC24V 1k-250k 20k-2M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068781 (LK5895.12\/020 DC24V 1k-250k 20k-2M) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/020 DC24V 1k-250k 20k-2M sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/020 DC24V 1k-250k 20k-2M is sold individually; the price shown is per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/020 DC24V 1k-250k 20k-2M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/020 DC24V 1k-250k 20k-2M?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407748043101,"sku":"0068781","price":1328.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-800-61-dc24v-1k-250k-0068838","title":"DOLD LK5895.12\/800\/61 DC24V 1k-250k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068838\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/800\/61 DC24V 1k-250k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068838\u003c\/strong\u003e (type LK5895.12\/800\/61 DC24V 1k-250k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Without analogue output. With adapted measuring algorithm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/800\/61 DC24V 1k-250k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/800\/61 DC24V 1k-250k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/800\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068838 (LK5895.12\/800\/61 DC24V 1k-250k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/800\/61 DC24V 1k-250k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/800\/61 DC24V 1k-250k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/800\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/800\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407748534621,"sku":"0068838","price":1328.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-040-61-dc24v-1k-250k-0068991","title":"DOLD LK5895.12\/040\/61 DC24V 1k-250k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068991\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/040\/61 DC24V 1k-250k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068991\u003c\/strong\u003e (type LK5895.12\/040\/61 DC24V 1k-250k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Without analogue output. With reduced measuring voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/040\/61 DC24V 1k-250k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/040\/61 DC24V 1k-250k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/040\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068991 (LK5895.12\/040\/61 DC24V 1k-250k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/040\/61 DC24V 1k-250k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/040\/61 DC24V 1k-250k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/040\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/040\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407749615965,"sku":"0068991","price":1328.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-801-61-dc24v-1k-250k-0069291","title":"DOLD LK5895.12\/801\/61 DC24V 1k-250k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069291\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/801\/61 DC24V 1k-250k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069291\u003c\/strong\u003e (type LK5895.12\/801\/61 DC24V 1k-250k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Analogue output with linear output function for displaying the insulation resistance. With adapted measuring algorithm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/801\/61 DC24V 1k-250k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/801\/61 DC24V 1k-250k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/801\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069291 (LK5895.12\/801\/61 DC24V 1k-250k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/801\/61 DC24V 1k-250k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/801\/61 DC24V 1k-250k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/801\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/801\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407753974109,"sku":"0069291","price":1515.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-801-61-dc24v-1k-250k-0069298","title":"DOLD LK5895.12\/801\/61 DC24V 1k-250k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069298\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/801\/61 DC24V 1k-250k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069298\u003c\/strong\u003e (type LK5895.12\/801\/61 DC24V 1k-250k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Analogue output with linear output function for displaying the insulation resistance. With adapted measuring algorithm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/801\/61 DC24V 1k-250k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/801\/61 DC24V 1k-250k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/801\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069298 (LK5895.12\/801\/61 DC24V 1k-250k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/801\/61 DC24V 1k-250k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/801\/61 DC24V 1k-250k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/801\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/801\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407754170717,"sku":"0069298","price":1515.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"},{"product_id":"dold-lk5895-12-800-61-dc24v-1k-250k-0069632","title":"DOLD LK5895.12\/800\/61 DC24V 1k-250k insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069632\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e LK5895.12\/800\/61 DC24V 1k-250k\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e LK 5895 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069632\u003c\/strong\u003e (type LK5895.12\/800\/61 DC24V 1k-250k) belongs to the “LK 5895” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe LK 5895 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via LEDs.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to 1000 V nominal voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for large system leakage capacitances up to 3000 μF\u003c\/li\u003e\n\u003cli\u003eExtremely simple setting via detent rotary switches\u003c\/li\u003e\n\u003cli\u003eFor monitoring photovoltaic systems, including those with thin-film technology\u003c\/li\u003e\n\u003cli\u003eOptimised measuring times – generally shorter than with known methods\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring for wire break\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit can be switched off via control terminals, e.g. for grid coupling\u003c\/li\u003e\n\u003cli\u003e1 changeover contact(s) each for pre-warning and alarm\u003c\/li\u003e\n\u003cli\u003ePre-warning threshold setting range: 20 kΩ ... 2 MΩ\u003c\/li\u003e\n\u003cli\u003eAlarm threshold setting range: 1 kΩ ... 250 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle selectable for output relay\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eSimple, clear setting of the device with a screwdriver\u003c\/li\u003e\n\u003cli\u003eLED chain for displaying the current insulation resistance\u003c\/li\u003e\n\u003cli\u003e“Measuring circuit active” indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eExternal test and reset buttons can be connected\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith wire break detection on L(+)\/L(-). Without analogue output. With adapted measuring algorithm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “LK 5895” product family comprises 10 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm value:\u003c\/strong\u003e 1 - 250 kOhm; 1 - 15 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e 20 kOhm - 2 MOhm; 2 - 18 kOhm; 5 - 500 kOhm; 1 - 250 kOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UL-listed C\/US, UKCA; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLK5895.12\/800\/61 DC24V 1k-250k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about LK5895.12\/800\/61 DC24V 1k-250k\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for LK5895.12\/800\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069632 (LK5895.12\/800\/61 DC24V 1k-250k) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is LK5895.12\/800\/61 DC24V 1k-250k sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eLK5895.12\/800\/61 DC24V 1k-250k is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for LK5895.12\/800\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for LK5895.12\/800\/61 DC24V 1k-250k?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the LK 5895 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/7b\/46\/39\/1781615117\/LK5895_de.pdf?ts=1789139281\" target=\"_blank\" rel=\"noopener\"\u003eData sheet LK 5895 (PDF, 564.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1d\/96\/9c\/1780410193\/LK589x.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro LK 589x (ZIP, 12.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e8\/5c\/45\/1746608096\/Flyer_Isolationswaechter_LK5895-96_F84.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor LK 5895 \/ LK 5896 (PDF, 279.32 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407757644125,"sku":"0069632","price":1328.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-LK5895.jpg?v=1793922617"}],"url":"https:\/\/www.iam24.de\/en\/collections\/dold-lk-5895.oembed","provider":"IAM24","version":"1.0","type":"link"}