{"title":"DOLD MH 9300 multifunction measuring relay","description":"\u003cp\u003eThe DOLD series \u003cstrong\u003eMH 9300\u003c\/strong\u003e (also MH9300) comprises 11 versions at IAM24 – mainly multifunction measuring relays. The variants differ mainly in supply voltage, measuring or setting range and contact configuration. All devices are genuine products from E. DOLD \u0026amp; Söhne; the type and DOLD article number are shown on every product page.\u003c\/p\u003e\u003cp\u003eMore from this area: \u003ca href=\"\/en\/collections\/dold-multifunktionale-messrelais\"\u003eDOLD multifunction measuring relays\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dold#baureihen\"\u003eAll DOLD series A–Z\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"dold-mh9300-12-022-3ac24-400v-ac12a-0063631","title":"DOLD MH9300.12\/022 3AC24-400V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0063631\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12\/022 3AC24-400V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0063631\u003c\/strong\u003e (type MH9300.12\/022 3AC24-400V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0063631\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12\/022 3AC24-400V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12\/022 3AC24-400V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0063631 (MH9300.12\/022 3AC24-400V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12\/022 3AC24-400V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12\/022 3AC24-400V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407595409757,"sku":"0063631","price":255.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12-022-3ac24-400v-ac12a-0063632","title":"DOLD MH9300.12\/022 3AC24-400V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0063632\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12\/022 3AC24-400V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0063632\u003c\/strong\u003e (type MH9300.12\/022 3AC24-400V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 110 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0063632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12\/022 3AC24-400V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12\/022 3AC24-400V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0063632 (MH9300.12\/022 3AC24-400V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12\/022 3AC24-400V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12\/022 3AC24-400V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407595475293,"sku":"0063632","price":278.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12ps-022-3ac24-690v-ac12a-0065120","title":"DOLD MH9300.12PS\/022 3AC24-690V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12PS\/022 3AC24-690V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065120\u003c\/strong\u003e (type MH9300.12PS\/022 3AC24-690V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRemovable terminal blocks with screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12PS\/022 3AC24-690V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12PS\/022 3AC24-690V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12PS\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065120 (MH9300.12PS\/022 3AC24-690V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12PS\/022 3AC24-690V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12PS\/022 3AC24-690V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12PS\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407669432669,"sku":"0065120","price":267.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12ps-022-3ac24-690v-ac12a-0065578","title":"DOLD MH9300.12PS\/022 3AC24-690V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065578\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12PS\/022 3AC24-690V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065578\u003c\/strong\u003e (type MH9300.12PS\/022 3AC24-690V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 110 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRemovable terminal blocks with screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065578\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12PS\/022 3AC24-690V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12PS\/022 3AC24-690V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12PS\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065578 (MH9300.12PS\/022 3AC24-690V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12PS\/022 3AC24-690V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12PS\/022 3AC24-690V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12PS\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407677690205,"sku":"0065578","price":290.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12-022-3ac24-690v-ac12a-0065630","title":"DOLD MH9300.12\/022 3AC24-690V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065630\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12\/022 3AC24-690V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065630\u003c\/strong\u003e (type MH9300.12\/022 3AC24-690V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 110 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12\/022 3AC24-690V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12\/022 3AC24-690V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065630 (MH9300.12\/022 3AC24-690V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12\/022 3AC24-690V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12\/022 3AC24-690V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407678050653,"sku":"0065630","price":278.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12-022-3ac24-690v-ac12a-0065631","title":"DOLD MH9300.12\/022 3AC24-690V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065631\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12\/022 3AC24-690V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065631\u003c\/strong\u003e (type MH9300.12\/022 3AC24-690V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065631\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12\/022 3AC24-690V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12\/022 3AC24-690V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065631 (MH9300.12\/022 3AC24-690V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12\/022 3AC24-690V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12\/022 3AC24-690V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407678083421,"sku":"0065631","price":255.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12-022-3ac24-690v-ac12a-0065632","title":"DOLD MH9300.12\/022 3AC24-690V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0065632\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12\/022 3AC24-690V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0065632\u003c\/strong\u003e (type MH9300.12\/022 3AC24-690V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0065632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12\/022 3AC24-690V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12\/022 3AC24-690V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0065632 (MH9300.12\/022 3AC24-690V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12\/022 3AC24-690V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12\/022 3AC24-690V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407678116189,"sku":"0065632","price":255.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12-022-3ac24-400v-ac12a-0066034","title":"DOLD MH9300.12\/022 3AC24-400V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0066034\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12\/022 3AC24-400V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0066034\u003c\/strong\u003e (type MH9300.12\/022 3AC24-400V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0066034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12\/022 3AC24-400V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12\/022 3AC24-400V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0066034 (MH9300.12\/022 3AC24-400V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12\/022 3AC24-400V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12\/022 3AC24-400V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407685161309,"sku":"0066034","price":255.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12pc-022-3ac24-400v-ac12a-0067760","title":"DOLD MH9300.12PC\/022 3AC24-400V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0067760\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12PC\/022 3AC24-400V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0067760\u003c\/strong\u003e (type MH9300.12PC\/022 3AC24-400V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRemovable terminal blocks with spring-loaded terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0067760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12PC\/022 3AC24-400V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12PC\/022 3AC24-400V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12PC\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0067760 (MH9300.12PC\/022 3AC24-400V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12PC\/022 3AC24-400V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12PC\/022 3AC24-400V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12PC\/022 3AC24-400V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407715275101,"sku":"0067760","price":273.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12-022-3ac24-690v-ac12a-0068123","title":"DOLD MH9300.12\/022 3AC24-690V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068123\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12\/022 3AC24-690V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068123\u003c\/strong\u003e (type MH9300.12\/022 3AC24-690V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068123\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12\/022 3AC24-690V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12\/022 3AC24-690V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068123 (MH9300.12\/022 3AC24-690V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12\/022 3AC24-690V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12\/022 3AC24-690V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407719666013,"sku":"0068123","price":255.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"},{"product_id":"dold-mh9300-12pc-022-3ac24-690v-ac12a-0068261","title":"DOLD MH9300.12PC\/022 3AC24-690V AC12A multifunction measuring relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068261\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MH9300.12PC\/022 3AC24-690V AC12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MH 9300 – multifunction measuring relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068261\u003c\/strong\u003e (type MH9300.12PC\/022 3AC24-690V AC12A) belongs to the “MH 9300” product family (monitoring technology – multifunction measuring relays).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9300N \/ MH 9300 universal measuring relays from the VARIMETER PRO series simultaneously monitor up to 9 different parameters, such as overvoltage, undervoltage, window voltage, voltage asymmetry, overcurrent \/ undercurrent, cos phi, active, apparent and reactive power, frequency and phase sequence. Measurement in three-phase and single-phase networks is very simple and possible without extensive wiring effort. Thanks to the menu structure, the multifunction measuring relays are simple and intuitive to operate. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMin, max or window monitoring\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to 9 measured variables\u003c\/li\u003e\n\u003cli\u003eSimple parameter setting and fault diagnostics on the device\u003c\/li\u003e\n\u003cli\u003eDifferentiated fault messages\u003c\/li\u003e\n\u003cli\u003eWide measuring range 3 AC 24 ... 690 V\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage ranges DC 24 V, AC 230 V or AC\/DC 110 ... 400 V\u003c\/li\u003e\n\u003cli\u003eEarly detection of irregularities\u003c\/li\u003e\n\u003cli\u003eCost-effective and space-saving\u003c\/li\u003e\n\u003cli\u003eReduced wiring effort\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMultifunction measuring relay to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring (1- and 3-phase)\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring\u003c\/li\u003e\n\u003cli\u003eFrequency monitoring\u003c\/li\u003e\n\u003cli\u003ePhase angle cos ϕ\u003c\/li\u003e\n\u003cli\u003ePhase sequence, phase failure, asymmetry\u003c\/li\u003e\n\u003cli\u003eActive, reactive and apparent power\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time, response delay\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis 0.2 ... 50 % of the response value\u003c\/li\u003e\n\u003cli\u003eFault memory\u003c\/li\u003e\n\u003cli\u003eLCD display for the current measured values\u003c\/li\u003e\n\u003cli\u003eRelay output MK 9300N: 1 changeover contact MH 9300: 2 x 1 changeover contact\u003c\/li\u003e\n\u003cli\u003eRelay function open-circuit \/ closed-circuit switchable\u003c\/li\u003e\n\u003cli\u003eOptionally with plug-in terminal blocks\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eWith spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 9300: 45.0 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRemovable terminal blocks with spring-loaded terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 24 - 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MH 9300” product family comprises IAM24 11 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC\/DC 110 - 400 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring voltage:\u003c\/strong\u003e 3AC 24 - 400 V; 3AC 24 - 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMH9300.12PC\/022 3AC24-690V AC12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MH9300.12PC\/022 3AC24-690V AC12A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MH9300.12PC\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068261 (MH9300.12PC\/022 3AC24-690V AC12A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MH9300.12PC\/022 3AC24-690V AC12A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMH9300.12PC\/022 3AC24-690V AC12A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MH9300.12PC\/022 3AC24-690V AC12A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/a0\/eb\/ee\/1787908031\/MK9300N_de.pdf?ts=1787908032\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9300N, MH 9300 (PDF, 688.37 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/24\/cb\/e4\/1746608208\/Flyer_Multifunktionales_Messrelais_MK9300N_F71.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relays MK 9300N (PDF, 2.71 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/bd\/19\/5b\/1746608091\/Flyer_Multifunktionales_Messrelais_MK9300N_F71B.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer universal measuring relay MK 9300N (PDF, 261.46 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407723794781,"sku":"0068261","price":273.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MH9300.jpg?v=1793922565"}],"url":"https:\/\/www.iam24.de\/en\/collections\/dold-mh-9300.oembed","provider":"IAM24","version":"1.0","type":"link"}