{"title":"DOLD MK 9837 frequency relay","description":"\u003cp\u003eThe DOLD series \u003cstrong\u003eMK 9837\u003c\/strong\u003e (also MK9837) comprises 11 versions at IAM24 – mainly frequency relays. The variants differ mainly in supply voltage, measuring or setting range and contact configuration. All devices are genuine products from E. DOLD \u0026amp; Söhne; the type and DOLD article number are shown on every product page.\u003c\/p\u003e\u003cp\u003eMore from this area: \u003ca href=\"\/en\/collections\/dold-messrelais-zur-netzueberwachung\"\u003eDOLD measuring relays for mains monitoring\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dold#baureihen\"\u003eAll DOLD series A–Z\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"dold-mk9837n-12-5-600hz-uh-ac230v-0058719","title":"DOLD MK9837N.12 5-600HZ UH AC230V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0058719\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12 5-600HZ UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0058719\u003c\/strong\u003e (type MK9837N.12 5-600HZ UH AC230V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 - 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0058719\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12 5-600HZ UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12 5-600HZ UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12 5-600HZ UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0058719 (MK9837N.12 5-600HZ UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is MK9837N.12 5-600HZ UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12 5-600HZ UH AC230V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12 5-600HZ UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404015047005,"sku":"0058719","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-12-050-1-5-200hz-uh-ac230v-0058720","title":"DOLD MK9837N.12\/050 1.5-200HZ UH AC230V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0058720\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12\/050 1.5-200HZ UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0058720\u003c\/strong\u003e (type MK9837N.12\/050 1.5-200HZ UH AC230V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency. With measuring input for frequency converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0058720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12\/050 1.5-200HZ UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12\/050 1.5-200HZ UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12\/050 1.5-200HZ UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0058720 (MK9837N.12\/050 1.5-200HZ UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.12\/050 1.5-200HZ UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12\/050 1.5-200HZ UH AC230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12\/050 1.5-200HZ UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404016914781,"sku":"0058720","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-38-500-2x5-600hz-uh-ac230v-0061295","title":"DOLD MK9837N.38\/500 2x5-600HZ UH=AC230V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0061295\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.38\/500 2x5-600HZ UH=AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N\/5_0 – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0061295\u003c\/strong\u003e (type MK9837N.38\/500 2x5-600HZ UH=AC230V) belongs to the “MK 9837N\/5_0” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N\/5_0 and MH 9837\/5_0 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/550) or for monitoring the rotor frequency of slip-ring motors. A further area of application is the monitoring of drives in crane systems.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDifferentiated fault messages for overfrequency and underfrequency\u003c\/li\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eMonitoring of AC voltages for overfrequency and underfrequency, also usable for pre-warning (for monitoring of AC voltages for overfrequency or underfrequency, see data sheet MK 9837N)\u003c\/li\u003e\n\u003cli\u003eSeparate relay outputs for overfrequency and underfrequency (1 or 2 changeover contact(s) each)\u003c\/li\u003e\n\u003cli\u003eAlternative window operating mode (monitoring of a frequency window)\u003c\/li\u003e\n\u003cli\u003eResponse value for overfrequency and underfrequency separately adjustable in 4 ranges each, 1.5 ... 200 Hz or 5 ... 600 Hz\u003c\/li\u003e\n\u003cli\u003eSecond response value also usable for pre-warning\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eHysteresis of the frequency thresholds programmable: 2...10 %\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time programmable via terminals from 0 ... 50 s or permanent\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837\/508: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eMH 9837\/5_0: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (relays drop out on alarm)\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eDevices optionally with 2 contact configurations. MK 9837N\/5_0: 2 x 1 changeover contact(s). MH 9837\/5_0: 2 x 2 changeover contact(s) or wide-range auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N\/5_0: 22.5 mm width. MH 9837\/5_0: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 5 - 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHysteresis\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency and underfrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MK 9837N\/5_0” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 2 x 5 - 600 Hz; 2 x 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0061295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.38\/500 2x5-600HZ UH=AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.38\/500 2x5-600HZ UH=AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.38\/500 2x5-600HZ UH=AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0061295 (MK9837N.38\/500 2x5-600HZ UH=AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.38\/500 2x5-600HZ UH=AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.38\/500 2x5-600HZ UH=AC230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.38\/500 2x5-600HZ UH=AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/be\/e0\/6d\/1746608133\/MK9837N_5_0_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N\/5_0, MH 9837\/5_0 (PDF, 369.51 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404091756893,"sku":"0061295","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N_500.jpg?v=1793922565"},{"product_id":"dold-mk9837n-12-5-600hz-uh-dc24v-0061393","title":"DOLD MK9837N.12 5-600HZ UH DC24V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0061393\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12 5-600HZ UH DC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0061393\u003c\/strong\u003e (type MK9837N.12 5-600HZ UH DC24V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 - 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0061393\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12 5-600HZ UH DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12 5-600HZ UH DC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12 5-600HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0061393 (MK9837N.12 5-600HZ UH DC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is MK9837N.12 5-600HZ UH DC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12 5-600HZ UH DC24V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12 5-600HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404092281181,"sku":"0061393","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-12-1-5-200hz-uh-dc24v-0062245","title":"DOLD MK9837N.12 1.5-200HZ UH DC24V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0062245\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12 1.5-200HZ UH DC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0062245\u003c\/strong\u003e (type MK9837N.12 1.5-200HZ UH DC24V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0062245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12 1.5-200HZ UH DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12 1.5-200HZ UH DC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12 1.5-200HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0062245 (MK9837N.12 1.5-200HZ UH DC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.12 1.5-200HZ UH DC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12 1.5-200HZ UH DC24V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12 1.5-200HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407570407773,"sku":"0062245","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-12-050-1-5-200hz-uh-dc24v-0062337","title":"DOLD MK9837N.12\/050 1.5-200HZ UH DC24V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0062337\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12\/050 1.5-200HZ UH DC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0062337\u003c\/strong\u003e (type MK9837N.12\/050 1.5-200HZ UH DC24V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency. With measuring input for frequency converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0062337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12\/050 1.5-200HZ UH DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12\/050 1.5-200HZ UH DC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12\/050 1.5-200HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0062337 (MK9837N.12\/050 1.5-200HZ UH DC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.12\/050 1.5-200HZ UH DC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12\/050 1.5-200HZ UH DC24V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12\/050 1.5-200HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407570702685,"sku":"0062337","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-12-1-5-200hz-uh-ac230v-0063171","title":"DOLD MK9837N.12 1.5-200HZ UH AC230V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0063171\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12 1.5-200HZ UH AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0063171\u003c\/strong\u003e (type MK9837N.12 1.5-200HZ UH AC230V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0063171\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12 1.5-200HZ UH AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12 1.5-200HZ UH AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12 1.5-200HZ UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0063171 (MK9837N.12 1.5-200HZ UH AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.12 1.5-200HZ UH AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12 1.5-200HZ UH AC230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12 1.5-200HZ UH AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407587742045,"sku":"0063171","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-12-050-1-5-200hz-uh-ac400v-0063963","title":"DOLD MK9837N.12\/050 1.5-200HZ UH AC400V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0063963\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12\/050 1.5-200HZ UH AC400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0063963\u003c\/strong\u003e (type MK9837N.12\/050 1.5-200HZ UH AC400V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.5 - 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency. With measuring input for frequency converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0063963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12\/050 1.5-200HZ UH AC400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12\/050 1.5-200HZ UH AC400V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12\/050 1.5-200HZ UH AC400V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0063963 (MK9837N.12\/050 1.5-200HZ UH AC400V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.12\/050 1.5-200HZ UH AC400V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12\/050 1.5-200HZ UH AC400V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12\/050 1.5-200HZ UH AC400V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407604257117,"sku":"0063963","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-12-050-5-600hz-uh-dc24v-0066317","title":"DOLD MK9837N.12\/050 5-600HZ UH DC24V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0066317\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.12\/050 5-600HZ UH DC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0066317\u003c\/strong\u003e (type MK9837N.12\/050 5-600HZ UH DC24V) belongs to the “MK 9837N” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N and MH 9837 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/050) or for monitoring the rotor frequency of slip-ring motors. Further areas of application are the monitoring of drives in crane systems, as well as frequency monitoring of the supply voltage in rail vehicles.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of overfrequency or underfrequency of AC voltages (function switchable) (for monitoring of overfrequency and underfrequency, see data sheet MK 9837N\/5_0)\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eAdjustable response value 1.5 ... 200 Hz or 5 ... 600 Hz in 4 ranges each\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable start-up bypass time 0 ... 50 s for underfrequency function\u003c\/li\u003e\n\u003cli\u003eAdjustable monitoring time for missing input signal with overfrequency function\u003c\/li\u003e\n\u003cli\u003eAlarm delay programmable via terminals from 0 ... 100 s\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s), closed-circuit principle (relay drops out on alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit principle on request\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eMH 9837.12\/008: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eFor the device with 2 frequency thresholds and separately controlled output relays for underfrequency and overfrequency, see MK 9837N\/500\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N: 22.5 mm width. MH 9837: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 - 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency or underfrequency. With measuring input for frequency converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 9837N” product family comprises 8 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 5 - 600 Hz; 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V; AC 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0066317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.12\/050 5-600HZ UH DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.12\/050 5-600HZ UH DC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.12\/050 5-600HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0066317 (MK9837N.12\/050 5-600HZ UH DC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is MK9837N.12\/050 5-600HZ UH DC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.12\/050 5-600HZ UH DC24V is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.12\/050 5-600HZ UH DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/d2\/f0\/6b\/1746608132\/MK9837N_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N, MH 9837 (PDF, 362.36 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407691813213,"sku":"0066317","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N.jpg?v=1793922520"},{"product_id":"dold-mk9837n-38-550-2x1-5-200hz-tv-0-0067603","title":"DOLD MK9837N.38\/550 2x1,5-200HZ Tv=0 frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0067603\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.38\/550 2x1,5-200HZ Tv=0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N\/5_0 – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0067603\u003c\/strong\u003e (type MK9837N.38\/550 2x1,5-200HZ Tv=0) belongs to the “MK 9837N\/5_0” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N\/5_0 and MH 9837\/5_0 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/550) or for monitoring the rotor frequency of slip-ring motors. A further area of application is the monitoring of drives in crane systems.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDifferentiated fault messages for overfrequency and underfrequency\u003c\/li\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eMonitoring of AC voltages for overfrequency and underfrequency, also usable for pre-warning (for monitoring of AC voltages for overfrequency or underfrequency, see data sheet MK 9837N)\u003c\/li\u003e\n\u003cli\u003eSeparate relay outputs for overfrequency and underfrequency (1 or 2 changeover contact(s) each)\u003c\/li\u003e\n\u003cli\u003eAlternative window operating mode (monitoring of a frequency window)\u003c\/li\u003e\n\u003cli\u003eResponse value for overfrequency and underfrequency separately adjustable in 4 ranges each, 1.5 ... 200 Hz or 5 ... 600 Hz\u003c\/li\u003e\n\u003cli\u003eSecond response value also usable for pre-warning\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eHysteresis of the frequency thresholds programmable: 2...10 %\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time programmable via terminals from 0 ... 50 s or permanent\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837\/508: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eMH 9837\/5_0: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (relays drop out on alarm)\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eDevices optionally with 2 contact configurations. MK 9837N\/5_0: 2 x 1 changeover contact(s). MH 9837\/5_0: 2 x 2 changeover contact(s) or wide-range auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N\/5_0: 22.5 mm width. MH 9837\/5_0: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1.5 - 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHysteresis\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency and underfrequency. With measuring input for frequency converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MK 9837N\/5_0” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 2 x 5 - 600 Hz; 2 x 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0067603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.38\/550 2x1,5-200HZ Tv=0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.38\/550 2x1,5-200HZ Tv=0\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.38\/550 2x1,5-200HZ Tv=0?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0067603 (MK9837N.38\/550 2x1,5-200HZ Tv=0) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.38\/550 2x1,5-200HZ Tv=0 sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.38\/550 2x1,5-200HZ Tv=0 is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.38\/550 2x1,5-200HZ Tv=0?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/be\/e0\/6d\/1746608133\/MK9837N_5_0_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N\/5_0, MH 9837\/5_0 (PDF, 369.51 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407712096605,"sku":"0067603","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N_500.jpg?v=1793922565"},{"product_id":"dold-mk9837n-38-550-2x5-600hz-uh-ac230v-0068811","title":"DOLD MK9837N.38\/550 2x5-600HZ UH=AC230V frequency relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068811\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK9837N.38\/550 2x5-600HZ UH=AC230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 9837N\/5_0 – frequency relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068811\u003c\/strong\u003e (type MK9837N.38\/550 2x5-600HZ UH=AC230V) belongs to the “MK 9837N\/5_0” product family (monitoring technology – measuring relays for mains monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 9837N\/5_0 and MH 9837\/5_0 frequency relays are used for frequency monitoring of AC voltages. They are used for monitoring the output frequency of frequency converters (\/550) or for monitoring the rotor frequency of slip-ring motors. A further area of application is the monitoring of drives in crane systems.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDifferentiated fault messages for overfrequency and underfrequency\u003c\/li\u003e\n\u003cli\u003eUniversal use\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eMonitoring of AC voltages for overfrequency and underfrequency, also usable for pre-warning (for monitoring of AC voltages for overfrequency or underfrequency, see data sheet MK 9837N)\u003c\/li\u003e\n\u003cli\u003eSeparate relay outputs for overfrequency and underfrequency (1 or 2 changeover contact(s) each)\u003c\/li\u003e\n\u003cli\u003eAlternative window operating mode (monitoring of a frequency window)\u003c\/li\u003e\n\u003cli\u003eResponse value for overfrequency and underfrequency separately adjustable in 4 ranges each, 1.5 ... 200 Hz or 5 ... 600 Hz\u003c\/li\u003e\n\u003cli\u003eSecond response value also usable for pre-warning\u003c\/li\u003e\n\u003cli\u003eFast response time through period measurement of the input frequency\u003c\/li\u003e\n\u003cli\u003eUniversal measuring input for AC voltages from 15 ... 280 V and 30 ... 550 V\u003c\/li\u003e\n\u003cli\u003eOptionally measuring input for frequency converters\u003c\/li\u003e\n\u003cli\u003eHysteresis of the frequency thresholds programmable: 2...10 %\u003c\/li\u003e\n\u003cli\u003eStart-up bypass time programmable via terminals from 0 ... 50 s or permanent\u003c\/li\u003e\n\u003cli\u003eAlarm latching or auto-reset programmable via terminals\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between measuring input, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eMH 9837\/508: With galvanically isolated analogue output and 11-step LED bar display for current frequency\u003c\/li\u003e\n\u003cli\u003eMH 9837\/5_0: Available with wide voltage range for auxiliary voltage (AC\/DC 24 ... 60 V or AC\/DC 110 ... 230 V)\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (relays drop out on alarm)\u003c\/li\u003e\n\u003cli\u003eLED indicators for auxiliary voltage, measuring voltage and alarm state\u003c\/li\u003e\n\u003cli\u003eDevices optionally with 2 contact configurations. MK 9837N\/5_0: 2 x 1 changeover contact(s). MH 9837\/5_0: 2 x 2 changeover contact(s) or wide-range auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 compact designs: MK 9837N\/5_0: 22.5 mm width. MH 9837\/5_0: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 5 - 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHysteresis\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of AC voltages for overfrequency and underfrequency. With measuring input for frequency converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “MK 9837N\/5_0” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value:\u003c\/strong\u003e 2 x 5 - 600 Hz; 2 x 1.5 - 200 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; DC 24 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068811\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK9837N.38\/550 2x5-600HZ UH=AC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK9837N.38\/550 2x5-600HZ UH=AC230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK9837N.38\/550 2x5-600HZ UH=AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068811 (MK9837N.38\/550 2x5-600HZ UH=AC230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK9837N.38\/550 2x5-600HZ UH=AC230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK9837N.38\/550 2x5-600HZ UH=AC230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK9837N.38\/550 2x5-600HZ UH=AC230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/be\/e0\/6d\/1746608133\/MK9837N_5_0_de.pdf?ts=1781589862\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 9837N\/5_0, MH 9837\/5_0 (PDF, 369.51 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407748272477,"sku":"0068811","price":166.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK9837N_500.jpg?v=1793922565"}],"url":"https:\/\/www.iam24.de\/en\/collections\/dold-mk-9837.oembed","provider":"IAM24","version":"1.0","type":"link"}