{"title":"DOLD RN 5897 insulation monitor","description":"\u003cp\u003eThe DOLD series \u003cstrong\u003eRN 5897\u003c\/strong\u003e (also RN5897) comprises 26 versions at IAM24 – mainly insulation monitors. The variants differ mainly in supply voltage, measuring or setting range and contact configuration. All devices are genuine products from E. DOLD \u0026amp; Söhne; the type and DOLD article number are shown on every product page.\u003c\/p\u003e\u003cp\u003eMore from this area: \u003ca href=\"\/en\/collections\/dold-isolationswaechter\"\u003eDOLD insulation monitors\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dold#baureihen\"\u003eAll DOLD series A–Z\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"dold-rn5897-12-020-61-ac-dc24-60v-0068258","title":"DOLD RN5897.12\/020\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068258\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/020\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/020 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068258\u003c\/strong\u003e (type RN5897.12\/020\/61 AC\/DC24-60V) belongs to the “RN 5897\/020” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/020 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/020” product family comprises 6 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/020\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/020\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/020\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068258 (RN5897.12\/020\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/020\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/020\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/020\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/020\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/020 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/df\/cc\/56\/1787908037\/RN5897_020_DB.pdf?ts=1787908037\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/020 (PDF, 3.72 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e9\/3a\/91\/1746608096\/Flyer_Isolationswaechter_RN5897_020_F114.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/020 (PDF, 276.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/58\/48\/99\/1780410205\/RN5897_020.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/020 (ZIP, 307.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/77\/4e\/93\/1780410205\/RN5897_022.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/022 (ZIP, 208.17 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407722484061,"sku":"0068258","price":406.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_020.jpg?v=1793922664"},{"product_id":"dold-rn5897-12-020-61-ac-dc85-230v-0068259","title":"DOLD RN5897.12\/020\/61 AC\/DC85-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068259\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/020\/61 AC\/DC85-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/020 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068259\u003c\/strong\u003e (type RN5897.12\/020\/61 AC\/DC85-230V) belongs to the “RN 5897\/020” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/020 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 85 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/020” product family comprises 6 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/020\/61 AC\/DC85-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/020\/61 AC\/DC85-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/020\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068259 (RN5897.12\/020\/61 AC\/DC85-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/020\/61 AC\/DC85-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/020\/61 AC\/DC85-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/020\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/020\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/020 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/df\/cc\/56\/1787908037\/RN5897_020_DB.pdf?ts=1787908037\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/020 (PDF, 3.72 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e9\/3a\/91\/1746608096\/Flyer_Isolationswaechter_RN5897_020_F114.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/020 (PDF, 276.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/58\/48\/99\/1780410205\/RN5897_020.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/020 (ZIP, 307.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/77\/4e\/93\/1780410205\/RN5897_022.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/022 (ZIP, 208.17 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407722516829,"sku":"0068259","price":406.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_020.jpg?v=1793922664"},{"product_id":"dold-rn5897-12-020-61-dc12-24v-0068260","title":"DOLD RN5897.12\/020\/61 DC12-24V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068260\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/020\/61 DC12-24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/020 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068260\u003c\/strong\u003e (type RN5897.12\/020\/61 DC12-24V) belongs to the “RN 5897\/020” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/020 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 12 - 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/020” product family comprises 6 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/020\/61 DC12-24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/020\/61 DC12-24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/020\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068260 (RN5897.12\/020\/61 DC12-24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/020\/61 DC12-24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/020\/61 DC12-24V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/020\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/020\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/020 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/df\/cc\/56\/1787908037\/RN5897_020_DB.pdf?ts=1787908037\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/020 (PDF, 3.72 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e9\/3a\/91\/1746608096\/Flyer_Isolationswaechter_RN5897_020_F114.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/020 (PDF, 276.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/58\/48\/99\/1780410205\/RN5897_020.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/020 (ZIP, 307.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/77\/4e\/93\/1780410205\/RN5897_022.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/022 (ZIP, 208.17 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407723762013,"sku":"0068260","price":406.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_020.jpg?v=1793922664"},{"product_id":"dold-rn5897-12-240-61-ac-dc24-60v-0069123","title":"DOLD RN5897.12\/240\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069123\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/240\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/240 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069123\u003c\/strong\u003e (type RN5897.12\/240\/61 AC\/DC24-60V) belongs to the “RN 5897\/240” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/240 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The connection to the IT system to be monitored must be made via one of the coupling devices. Device parameter setting and adjustment of the response values are carried out simply and user-friendly via three rotary switches on the front of the device. A multicolour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range of - 40 ... + 70 °C\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response value and setting parameters using rotary switches\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResponse value (alarm) setting range: 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault alarm and device fault\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003eWith semiconductor output for outputting the insulation resistance (PWM)\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/240” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; DC 12 - 24 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069123\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/240\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/240\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/240\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069123 (RN5897.12\/240\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/240\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/240\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/240\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/240\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/240 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/18\/44\/aa\/1787908039\/RN5897_240_de.pdf?ts=1793866082\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/240 (PDF, 542.38 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/50\/53\/d4\/1780410226\/RN5897_240.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/240 (ZIP, 317.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407750402397,"sku":"0069123","price":427.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_240.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-240-61-dc12-24v-1k-500k-0069124","title":"DOLD RN5897.12\/240\/61 DC12-24V 1K-500K insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069124\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/240\/61 DC12-24V 1K-500K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/240 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069124\u003c\/strong\u003e (type RN5897.12\/240\/61 DC12-24V 1K-500K) belongs to the “RN 5897\/240” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/240 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The connection to the IT system to be monitored must be made via one of the coupling devices. Device parameter setting and adjustment of the response values are carried out simply and user-friendly via three rotary switches on the front of the device. A multicolour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range of - 40 ... + 70 °C\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response value and setting parameters using rotary switches\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResponse value (alarm) setting range: 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault alarm and device fault\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003eWith semiconductor output for outputting the insulation resistance (PWM)\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 12 - 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/240” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; DC 12 - 24 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/240\/61 DC12-24V 1K-500K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/240\/61 DC12-24V 1K-500K\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/240\/61 DC12-24V 1K-500K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069124 (RN5897.12\/240\/61 DC12-24V 1K-500K) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/240\/61 DC12-24V 1K-500K sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/240\/61 DC12-24V 1K-500K is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/240\/61 DC12-24V 1K-500K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/240\/61 DC12-24V 1K-500K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/240 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/18\/44\/aa\/1787908039\/RN5897_240_de.pdf?ts=1793866082\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/240 (PDF, 542.38 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/50\/53\/d4\/1780410226\/RN5897_240.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/240 (ZIP, 317.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407750533469,"sku":"0069124","price":414.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_240.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-240-61-ac-dc85-230v-0069125","title":"DOLD RN5897.12\/240\/61 AC\/DC85-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069125\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/240\/61 AC\/DC85-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/240 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069125\u003c\/strong\u003e (type RN5897.12\/240\/61 AC\/DC85-230V) belongs to the “RN 5897\/240” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/240 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The connection to the IT system to be monitored must be made via one of the coupling devices. Device parameter setting and adjustment of the response values are carried out simply and user-friendly via three rotary switches on the front of the device. A multicolour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range of - 40 ... + 70 °C\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response value and setting parameters using rotary switches\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResponse value (alarm) setting range: 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault alarm and device fault\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003eWith semiconductor output for outputting the insulation resistance (PWM)\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 85 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/240” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; DC 12 - 24 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/240\/61 AC\/DC85-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/240\/61 AC\/DC85-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/240\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069125 (RN5897.12\/240\/61 AC\/DC85-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/240\/61 AC\/DC85-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/240\/61 AC\/DC85-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/240\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/240\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/240 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/18\/44\/aa\/1787908039\/RN5897_240_de.pdf?ts=1793866082\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/240 (PDF, 542.38 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/50\/53\/d4\/1780410226\/RN5897_240.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/240 (ZIP, 317.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407750566237,"sku":"0069125","price":414.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_240.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-021-61-ac-dc24-60v-0069252","title":"DOLD RN5897.12\/021\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069252\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/021\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/021 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069252\u003c\/strong\u003e (type RN5897.12\/021\/61 AC\/DC24-60V) belongs to the “RN 5897\/021” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/021 insulation monitor from the VARIMETER IMD family is a solution for optimum insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering. The RN 5897\/021 also has a Modbus RTU interface. All measured values, device states and parameters can be read out via Modbus, as well as set and parameterised. All functions available on the device can also be operated via Modbus.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response values and setting parameters using rotary switches and menu navigation or via Modbus RTU interface\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact for insulation fault pre-alarm and insulation fault alarm, each electrically isolated\u003c\/li\u003e\n\u003cli\u003eWith galvanically isolated Modbus RTU interface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e2 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBus interface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/021” product family comprises 2 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 100 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/021\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/021\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/021\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069252 (RN5897.12\/021\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/021\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/021\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/021\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/021\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/021 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/ab\/5b\/e3\/1787908038\/RN5897_021_de.pdf?ts=1787908038\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/021 (PDF, 1.2 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/f1\/9a\/ea\/1780410228\/RN5897_021.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/021 (ZIP, 146.49 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407753777501,"sku":"0069252","price":451.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_021_Lueftungsschlitze.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-021-61-ac-dc100-230v-0069282","title":"DOLD RN5897.12\/021\/61 AC\/DC100-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069282\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/021\/61 AC\/DC100-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/021 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069282\u003c\/strong\u003e (type RN5897.12\/021\/61 AC\/DC100-230V) belongs to the “RN 5897\/021” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/021 insulation monitor from the VARIMETER IMD family is a solution for optimum insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering. The RN 5897\/021 also has a Modbus RTU interface. All measured values, device states and parameters can be read out via Modbus, as well as set and parameterised. All functions available on the device can also be operated via Modbus.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response values and setting parameters using rotary switches and menu navigation or via Modbus RTU interface\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact for insulation fault pre-alarm and insulation fault alarm, each electrically isolated\u003c\/li\u003e\n\u003cli\u003eWith galvanically isolated Modbus RTU interface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e2 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 100 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBus interface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/021” product family comprises 2 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 100 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/021\/61 AC\/DC100-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/021\/61 AC\/DC100-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/021\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069282 (RN5897.12\/021\/61 AC\/DC100-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/021\/61 AC\/DC100-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/021\/61 AC\/DC100-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/021\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/021\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/021 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/ab\/5b\/e3\/1787908038\/RN5897_021_de.pdf?ts=1787908038\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/021 (PDF, 1.2 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/f1\/9a\/ea\/1780410228\/RN5897_021.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/021 (ZIP, 146.49 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407753908573,"sku":"0069282","price":451.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_021_Lueftungsschlitze.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-321-61-ac-dc24-60v-0069399","title":"DOLD RN5897.12\/321\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069399\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/321\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/321 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069399\u003c\/strong\u003e (type RN5897.12\/321\/61 AC\/DC24-60V) belongs to the “RN 5897\/321” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/321 insulation monitor from the VARIMETER IMD family is a solution for optimum insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V that require an extended operating temperature range. Device parameterisation and setting of the response values are carried out via Modbus. All measured values, device states and parameters can also be read out via Modbus. All functions available on the device can also be operated via Modbus. A multi-colour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range of - 40 ... + 70 °C\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response values and setting parameters via Modbus\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eWith galvanically isolated Modbus RTU interface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e2 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBus interface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/321” product family comprises 2 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 100 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069399\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/321\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/321\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/321\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069399 (RN5897.12\/321\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/321\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/321\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/321\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/321\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/321 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1c\/ac\/ef\/1787908046\/RN5897_321_de.pdf?ts=1787908046\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/321 (PDF, 577 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/8e\/f6\/26\/1780410228\/RN5897_321.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/321 (ZIP, 153.64 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407755186525,"sku":"0069399","price":446.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_321.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-321-61-ac-dc100-230v-0069400","title":"DOLD RN5897.12\/321\/61 AC\/DC100-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/321\/61 AC\/DC100-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/321 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069400\u003c\/strong\u003e (type RN5897.12\/321\/61 AC\/DC100-230V) belongs to the “RN 5897\/321” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/321 insulation monitor from the VARIMETER IMD family is a solution for optimum insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V that require an extended operating temperature range. Device parameterisation and setting of the response values are carried out via Modbus. All measured values, device states and parameters can also be read out via Modbus. All functions available on the device can also be operated via Modbus. A multi-colour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eUniversally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range of - 40 ... + 70 °C\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response values and setting parameters via Modbus\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eWith galvanically isolated Modbus RTU interface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e2 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 100 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBus interface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/321” product family comprises 2 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 100 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/321\/61 AC\/DC100-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/321\/61 AC\/DC100-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/321\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069400 (RN5897.12\/321\/61 AC\/DC100-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/321\/61 AC\/DC100-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/321\/61 AC\/DC100-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/321\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/321\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/321 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/1c\/ac\/ef\/1787908046\/RN5897_321_de.pdf?ts=1787908046\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/321 (PDF, 577 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/8e\/f6\/26\/1780410228\/RN5897_321.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/321 (ZIP, 153.64 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407755219293,"sku":"0069400","price":446.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_321.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-022-61-dc12-24v-0069634","title":"DOLD RN5897.12\/022\/61 DC12-24V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069634\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/022\/61 DC12-24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/020 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069634\u003c\/strong\u003e (type RN5897.12\/022\/61 DC12-24V) belongs to the “RN 5897\/020” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/020 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 12 - 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith reduced measuring voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/020” product family comprises 6 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/022\/61 DC12-24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/022\/61 DC12-24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/022\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069634 (RN5897.12\/022\/61 DC12-24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/022\/61 DC12-24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/022\/61 DC12-24V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/022\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/022\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/020 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/df\/cc\/56\/1787908037\/RN5897_020_DB.pdf?ts=1787908037\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/020 (PDF, 3.72 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e9\/3a\/91\/1746608096\/Flyer_Isolationswaechter_RN5897_020_F114.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/020 (PDF, 276.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/58\/48\/99\/1780410205\/RN5897_020.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/020 (ZIP, 307.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/77\/4e\/93\/1780410205\/RN5897_022.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/022 (ZIP, 208.17 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407757807965,"sku":"0069634","price":406.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_020.jpg?v=1793922664"},{"product_id":"dold-rn5897-12-022-61-ac-dc24-60v-0069635","title":"DOLD RN5897.12\/022\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069635\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/022\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/020 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069635\u003c\/strong\u003e (type RN5897.12\/022\/61 AC\/DC24-60V) belongs to the “RN 5897\/020” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/020 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith reduced measuring voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/020” product family comprises 6 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/022\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/022\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/022\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069635 (RN5897.12\/022\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/022\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/022\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/022\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/022\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/020 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/df\/cc\/56\/1787908037\/RN5897_020_DB.pdf?ts=1787908037\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/020 (PDF, 3.72 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e9\/3a\/91\/1746608096\/Flyer_Isolationswaechter_RN5897_020_F114.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/020 (PDF, 276.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/58\/48\/99\/1780410205\/RN5897_020.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/020 (ZIP, 307.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/77\/4e\/93\/1780410205\/RN5897_022.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/022 (ZIP, 208.17 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407758004573,"sku":"0069635","price":406.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_020.jpg?v=1793922664"},{"product_id":"dold-rn5897-12-022-61-ac-dc85-230v-0069636","title":"DOLD RN5897.12\/022\/61 AC\/DC85-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0069636\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/022\/61 AC\/DC85-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/020 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0069636\u003c\/strong\u003e (type RN5897.12\/022\/61 AC\/DC85-230V) belongs to the “RN 5897\/020” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/020 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. The main areas of application are ungrounded DC charging stations for electric vehicles with mains voltages up to DC 1000 V. The response values are set simply and in an operator-friendly way using two rotary switches on the front of the unit. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuitable for DC charging stations for electric vehicles to IEC\/EN 61851-23:2014\/AC:2016-06\u003c\/li\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V or RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V\u003c\/li\u003e\n\u003cli\u003eVery fast response time ≤ 1 s\u003c\/li\u003e\n\u003cli\u003eOptimised insulation resistance measurement even with mains voltage fluctuations (by evaluating the mains voltage)\u003c\/li\u003e\n\u003cli\u003eSelf-test after every full operating hour\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 5 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e1 changeover contact each for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button with additional stop of the measuring function\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 85 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith reduced measuring voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor DC charging stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/020” product family comprises 6 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0069636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/022\/61 AC\/DC85-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/022\/61 AC\/DC85-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/022\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0069636 (RN5897.12\/022\/61 AC\/DC85-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/022\/61 AC\/DC85-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/022\/61 AC\/DC85-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/022\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/022\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/020 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/df\/cc\/56\/1787908037\/RN5897_020_DB.pdf?ts=1787908037\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/020 (PDF, 3.72 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/e9\/3a\/91\/1746608096\/Flyer_Isolationswaechter_RN5897_020_F114.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/020 (PDF, 276.91 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/58\/48\/99\/1780410205\/RN5897_020.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/020 (ZIP, 307.77 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/77\/4e\/93\/1780410205\/RN5897_022.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/022 (ZIP, 208.17 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407758070109,"sku":"0069636","price":406.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_020.jpg?v=1793922664"},{"product_id":"dold-rn5897-12-010-61-ac-dc24-60v-0070011","title":"DOLD RN5897.12\/010\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070011\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/010\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/010 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070011\u003c\/strong\u003e (type RN5897.12\/010\/61 AC\/DC24-60V) belongs to the “RN 5897\/010” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/010 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device: RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V RR 5898*) for nominal voltages up to AC 1000 V \/ DC 1500 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 1000 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eTrigger output for insulation fault location system\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/010” product family comprises 5 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and markings:\u003c\/strong\u003e UL-listed C\/US, CCC, DNV; UL-listed C\/US, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/010\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/010\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/010\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070011 (RN5897.12\/010\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/010\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/010\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/010\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/010\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/010 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b4\/30\/f9\/1787908034\/RN5897_010_de.pdf?ts=1787908034\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/010 (PDF, 1.5 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/0e\/d1\/5a\/1788957232\/RN5897_010.zip?ts=1789551073\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/010 (ZIP, 213.03 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/97\/5a\/cf\/1746608090\/Flyer_Isolationswaechter_RN5897_010_F96.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/010 (PDF, 251.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761051997,"sku":"0070011","price":412.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_010.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-010-61-ac-dc85-230v-0070012","title":"DOLD RN5897.12\/010\/61 AC\/DC85-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/010\/61 AC\/DC85-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/010 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070012\u003c\/strong\u003e (type RN5897.12\/010\/61 AC\/DC85-230V) belongs to the “RN 5897\/010” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/010 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device: RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V RR 5898*) for nominal voltages up to AC 1000 V \/ DC 1500 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 1000 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eTrigger output for insulation fault location system\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 85 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/010” product family comprises 5 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and markings:\u003c\/strong\u003e UL-listed C\/US, CCC, DNV; UL-listed C\/US, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/010\/61 AC\/DC85-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/010\/61 AC\/DC85-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/010\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070012 (RN5897.12\/010\/61 AC\/DC85-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/010\/61 AC\/DC85-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/010\/61 AC\/DC85-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/010\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/010\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/010 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b4\/30\/f9\/1787908034\/RN5897_010_de.pdf?ts=1787908034\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/010 (PDF, 1.5 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/0e\/d1\/5a\/1788957232\/RN5897_010.zip?ts=1789551073\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/010 (ZIP, 213.03 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/97\/5a\/cf\/1746608090\/Flyer_Isolationswaechter_RN5897_010_F96.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/010 (PDF, 251.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761117533,"sku":"0070012","price":412.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_010.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-010-61-dc12-24v-0070013","title":"DOLD RN5897.12\/010\/61 DC12-24V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070013\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/010\/61 DC12-24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/010 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070013\u003c\/strong\u003e (type RN5897.12\/010\/61 DC12-24V) belongs to the “RN 5897\/010” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/010 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device: RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V RR 5898*) for nominal voltages up to AC 1000 V \/ DC 1500 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 1000 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eTrigger output for insulation fault location system\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 12 - 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/010” product family comprises 5 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and markings:\u003c\/strong\u003e UL-listed C\/US, CCC, DNV; UL-listed C\/US, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/010\/61 DC12-24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/010\/61 DC12-24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/010\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070013 (RN5897.12\/010\/61 DC12-24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/010\/61 DC12-24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/010\/61 DC12-24V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/010\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/010\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/010 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b4\/30\/f9\/1787908034\/RN5897_010_de.pdf?ts=1787908034\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/010 (PDF, 1.5 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/0e\/d1\/5a\/1788957232\/RN5897_010.zip?ts=1789551073\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/010 (ZIP, 213.03 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/97\/5a\/cf\/1746608090\/Flyer_Isolationswaechter_RN5897_010_F96.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/010 (PDF, 251.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761248605,"sku":"0070013","price":412.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_010.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-011-61-ac-dc24-60v-0070014","title":"DOLD RN5897.12\/011\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070014\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/011\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/011 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070014\u003c\/strong\u003e (type RN5897.12\/011\/61 AC\/DC24-60V) belongs to the “RN 5897\/011” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/011 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering. The RN 5897\/011 also has a Modbus RTU interface. All measured values, device states and parameters can be read out via Modbus, as well as set and parameterised. All functions available on the device can also be operated via Modbus.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device: RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V RR 5898*) for nominal voltages up to AC 1000 V \/ DC 1500 V\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response values and setting parameters using rotary switches and menu navigation or via Modbus RTU interface\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 1000 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact for insulation fault pre-alarm and insulation fault alarm, each electrically isolated\u003c\/li\u003e\n\u003cli\u003eWith galvanically isolated Modbus RTU interface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eTrigger output for insulation fault location system\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 1 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. response value (alarm): 1 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e2 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 2000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBus interface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/011” product family comprises 2 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 100 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/011\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/011\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/011\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070014 (RN5897.12\/011\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/011\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/011\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/011\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/011\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/011 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/10\/56\/95\/1787908036\/RN5897_011_de.pdf?ts=1787908036\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/011 (PDF, 1.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/6f\/6d\/90\/1746608116\/Anwenderhandbuch_MODBUS.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eUser manual Modbus RTU (PDF, 349.2 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/38\/76\/e5\/1788957232\/RN5897_011.zip?ts=1789551092\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/011 (ZIP, 94.72 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761346909,"sku":"0070014","price":462.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_011_Lueftungsschlitze.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-011-61-ac-dc100-230v-0070015","title":"DOLD RN5897.12\/011\/61 AC\/DC100-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070015\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/011\/61 AC\/DC100-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/011 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070015\u003c\/strong\u003e (type RN5897.12\/011\/61 AC\/DC100-230V) belongs to the “RN 5897\/011” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/011 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering. The RN 5897\/011 also has a Modbus RTU interface. All measured values, device states and parameters can be read out via Modbus, as well as set and parameterised. All functions available on the device can also be operated via Modbus.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device: RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V RR 5898*) for nominal voltages up to AC 1000 V \/ DC 1500 V\u003c\/li\u003e\n\u003cli\u003eEasy setting of the response values and setting parameters using rotary switches and menu navigation or via Modbus RTU interface\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 1000 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003e2 changeover contact for insulation fault pre-alarm and insulation fault alarm, each electrically isolated\u003c\/li\u003e\n\u003cli\u003eWith galvanically isolated Modbus RTU interface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eTrigger output for insulation fault location system\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 1 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. response value (alarm): 1 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e2 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 100 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 2000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBus interface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/011” product family comprises 2 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 100 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/011\/61 AC\/DC100-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/011\/61 AC\/DC100-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/011\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070015 (RN5897.12\/011\/61 AC\/DC100-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/011\/61 AC\/DC100-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/011\/61 AC\/DC100-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/011\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/011\/61 AC\/DC100-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/011 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/10\/56\/95\/1787908036\/RN5897_011_de.pdf?ts=1787908036\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/011 (PDF, 1.65 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/6f\/6d\/90\/1746608116\/Anwenderhandbuch_MODBUS.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eUser manual Modbus RTU (PDF, 349.2 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/38\/76\/e5\/1788957232\/RN5897_011.zip?ts=1789551092\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/011 (ZIP, 94.72 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761379677,"sku":"0070015","price":462.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_011_Lueftungsschlitze.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-060-61-ac-dc24-60v-0070016","title":"DOLD RN5897.12\/060\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070016\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/060\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/010 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070016\u003c\/strong\u003e (type RN5897.12\/060\/61 AC\/DC24-60V) belongs to the “RN 5897\/010” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/010 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device: RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V RR 5898*) for nominal voltages up to AC 1000 V \/ DC 1500 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 1000 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eTrigger output for insulation fault location system\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith measurement stop function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/010” product family comprises 5 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and markings:\u003c\/strong\u003e UL-listed C\/US, CCC, DNV; UL-listed C\/US, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/060\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/060\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/060\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070016 (RN5897.12\/060\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/060\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/060\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/060\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/060\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/010 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b4\/30\/f9\/1787908034\/RN5897_010_de.pdf?ts=1787908034\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/010 (PDF, 1.5 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/0e\/d1\/5a\/1788957232\/RN5897_010.zip?ts=1789551073\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/010 (ZIP, 213.03 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/97\/5a\/cf\/1746608090\/Flyer_Isolationswaechter_RN5897_010_F96.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/010 (PDF, 251.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761412445,"sku":"0070016","price":412.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_010.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-060-61-ac-dc85-230v-0070017","title":"DOLD RN5897.12\/060\/61 AC\/DC85-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070017\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/060\/61 AC\/DC85-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/010 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070017\u003c\/strong\u003e (type RN5897.12\/060\/61 AC\/DC85-230V) belongs to the “RN 5897\/010” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/010 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault location through selective earth fault detection to L+ and L- Universally applicable in ungrounded AC, DC and AC\/DC systems up to AC max. 250 V or DC max. 300 V\u003c\/li\u003e\n\u003cli\u003eWith connection option for an external coupling device: RL 5898 for nominal voltages up to AC 400 V \/ DC 500 V RP 5898 for nominal voltages up to AC 690 V \/ DC 1000 V RR 5898*) for nominal voltages up to AC 1000 V \/ DC 1500 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 1000 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eTrigger output for insulation fault location system\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 2 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 1 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 85 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 2 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWith measurement stop function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/010” product family comprises 5 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 - 60 V; AC\/DC 85 - 230 V; DC 12 - 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and markings:\u003c\/strong\u003e UL-listed C\/US, CCC, DNV; UL-listed C\/US, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/060\/61 AC\/DC85-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/060\/61 AC\/DC85-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/060\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070017 (RN5897.12\/060\/61 AC\/DC85-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/060\/61 AC\/DC85-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/060\/61 AC\/DC85-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/060\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/060\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/010 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b4\/30\/f9\/1787908034\/RN5897_010_de.pdf?ts=1787908034\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/010 (PDF, 1.5 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/0e\/d1\/5a\/1788957232\/RN5897_010.zip?ts=1789551073\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/010 (ZIP, 213.03 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/97\/5a\/cf\/1746608090\/Flyer_Isolationswaechter_RN5897_010_F96.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/010 (PDF, 251.33 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4d\/24\/38\/1780410194\/Flyer_DNV_Zulassung_F129.pdf?ts=1788514785\" target=\"_blank\" rel=\"noopener\"\u003eFlyer DNV certification (PDF, 539.45 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761445213,"sku":"0070017","price":412.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_010.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-61-dc12-24v-15k-100k-0070034","title":"DOLD RN5897.12\/61 DC12-24V 15K-100K insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070034\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/61 DC12-24V 15K-100K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070034\u003c\/strong\u003e (type RN5897.12\/61 DC12-24V 15K-100K) belongs to the “RN 5897” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897 insulation monitor from the VARIMETER IMD family is a solution for optimum insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo DIN VDE 0100-551 for mobile generators\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 300 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 15 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e15 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 12 - 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor mobile generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e DC 12 - 24 V; AC\/DC 24 - 60 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/61 DC12-24V 15K-100K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/61 DC12-24V 15K-100K\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/61 DC12-24V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070034 (RN5897.12\/61 DC12-24V 15K-100K) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/61 DC12-24V 15K-100K sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/61 DC12-24V 15K-100K is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/61 DC12-24V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/61 DC12-24V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/85\/c0\/04\/1787832333\/RN5897_de.pdf?ts=1787832333\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897 (PDF, 1.14 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b3\/0d\/c6\/1788957231\/RN5897.zip?ts=1789551063\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897 (ZIP, 215.04 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761576285,"sku":"0070034","price":304.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-61-ac-dc24-60v-15k-100k-0070035","title":"DOLD RN5897.12\/61 AC\/DC24-60V 15K-100K insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/61 AC\/DC24-60V 15K-100K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070035\u003c\/strong\u003e (type RN5897.12\/61 AC\/DC24-60V 15K-100K) belongs to the “RN 5897” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897 insulation monitor from the VARIMETER IMD family is a solution for optimum insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo DIN VDE 0100-551 for mobile generators\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 300 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 15 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e15 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor mobile generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e DC 12 - 24 V; AC\/DC 24 - 60 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/61 AC\/DC24-60V 15K-100K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/61 AC\/DC24-60V 15K-100K\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/61 AC\/DC24-60V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070035 (RN5897.12\/61 AC\/DC24-60V 15K-100K) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/61 AC\/DC24-60V 15K-100K sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/61 AC\/DC24-60V 15K-100K is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/61 AC\/DC24-60V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/61 AC\/DC24-60V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/85\/c0\/04\/1787832333\/RN5897_de.pdf?ts=1787832333\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897 (PDF, 1.14 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b3\/0d\/c6\/1788957231\/RN5897.zip?ts=1789551063\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897 (ZIP, 215.04 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761609053,"sku":"0070035","price":304.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-61-ac-dc85-230v-15k-100k-0070036","title":"DOLD RN5897.12\/61 AC\/DC85-230V 15K-100K insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070036\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/61 AC\/DC85-230V 15K-100K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070036\u003c\/strong\u003e (type RN5897.12\/61 AC\/DC85-230V 15K-100K) belongs to the “RN 5897” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897 insulation monitor from the VARIMETER IMD family is a solution for optimum insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks, even with high system leakage capacitances to PE. The response values are set simply and user-friendly via two rotary switches on the front of the device. Measured values, device parameters and device states can be read off user-friendly via a multicolour illuminated display. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo DIN VDE 0100-551 for mobile generators\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eFast fault localisation through selective earth fault detection to L+ and L-. Universally usable in unearthed AC, DC and AC\/DC networks up to max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches and menu guidance\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 300 μF\u003c\/li\u003e\n\u003cli\u003eOptimised response time with high system leakage capacitances\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 500 kΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 15 kΩ … 100 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eMulticolour display for showing the current insulation resistance, the device state and for parameterisation\u003c\/li\u003e\n\u003cli\u003eSetting of the maximum system leakage capacitance to shorten the response time\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e15 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 85 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 - 500 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor mobile generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e DC 12 - 24 V; AC\/DC 24 - 60 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/61 AC\/DC85-230V 15K-100K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/61 AC\/DC85-230V 15K-100K\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/61 AC\/DC85-230V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070036 (RN5897.12\/61 AC\/DC85-230V 15K-100K) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/61 AC\/DC85-230V 15K-100K sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/61 AC\/DC85-230V 15K-100K is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/61 AC\/DC85-230V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/61 AC\/DC85-230V 15K-100K?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/85\/c0\/04\/1787832333\/RN5897_de.pdf?ts=1787832333\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897 (PDF, 1.14 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/b3\/0d\/c6\/1788957231\/RN5897.zip?ts=1789551063\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897 (ZIP, 215.04 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761674589,"sku":"0070036","price":304.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-300-61-dc12-24v-0070147","title":"DOLD RN5897.12\/300\/61 DC12-24V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070147\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/300\/61 DC12-24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/300 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070147\u003c\/strong\u003e (type RN5897.12\/300\/61 DC12-24V) belongs to the “RN 5897\/300” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/300 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. Device parameter setting and adjustment of the response values are carried out simply and user-friendly via three rotary switches on the front of the device. A multicolour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo DIN VDE 0100-551 for mobile generators\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eUniversally usable in unearthed AC, DC and AC\/DC networks up to max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 30 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 1 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 10 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 12 - 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor mobile generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/300” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e DC 12 - 24 V; AC\/DC 24 - 60 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/300\/61 DC12-24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/300\/61 DC12-24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/300\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070147 (RN5897.12\/300\/61 DC12-24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/300\/61 DC12-24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/300\/61 DC12-24V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/300\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/300\/61 DC12-24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/300 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/87\/63\/63\/1787908040\/RN5897_300_de.pdf?ts=1787908040\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/300 (PDF, 816.67 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/47\/cb\/af\/1788957219\/RN5897_300.zip?ts=1789551111\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/300 (ZIP, 94.54 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2f\/11\/c0\/1746608063\/Flyer_Isolationswaechter_RN5897_300_F96B.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/300 (PDF, 188.61 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761871197,"sku":"0070147","price":299.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_300.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-300-61-ac-dc24-60v-0070148","title":"DOLD RN5897.12\/300\/61 AC\/DC24-60V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070148\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/300\/61 AC\/DC24-60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/300 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070148\u003c\/strong\u003e (type RN5897.12\/300\/61 AC\/DC24-60V) belongs to the “RN 5897\/300” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/300 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. Device parameter setting and adjustment of the response values are carried out simply and user-friendly via three rotary switches on the front of the device. A multicolour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo DIN VDE 0100-551 for mobile generators\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eUniversally usable in unearthed AC, DC and AC\/DC networks up to max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 30 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 1 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 10 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor mobile generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/300” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e DC 12 - 24 V; AC\/DC 24 - 60 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/300\/61 AC\/DC24-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/300\/61 AC\/DC24-60V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/300\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070148 (RN5897.12\/300\/61 AC\/DC24-60V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/300\/61 AC\/DC24-60V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/300\/61 AC\/DC24-60V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/300\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/300\/61 AC\/DC24-60V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/300 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/87\/63\/63\/1787908040\/RN5897_300_de.pdf?ts=1787908040\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/300 (PDF, 816.67 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/47\/cb\/af\/1788957219\/RN5897_300.zip?ts=1789551111\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/300 (ZIP, 94.54 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2f\/11\/c0\/1746608063\/Flyer_Isolationswaechter_RN5897_300_F96B.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/300 (PDF, 188.61 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761903965,"sku":"0070148","price":299.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_300.jpg?v=1793922679"},{"product_id":"dold-rn5897-12-300-61-ac-dc85-230v-0070149","title":"DOLD RN5897.12\/300\/61 AC\/DC85-230V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0070149\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RN5897.12\/300\/61 AC\/DC85-230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RN 5897\/300 – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0070149\u003c\/strong\u003e (type RN5897.12\/300\/61 AC\/DC85-230V) belongs to the “RN 5897\/300” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RN 5897\/300 insulation monitor from the VARIMETER IMD family is a solution for optimum, up-to-date insulation monitoring of modern IT systems. The device can be used flexibly in AC, DC and mixed AC\/DC networks. Device parameter setting and adjustment of the response values are carried out simply and user-friendly via three rotary switches on the front of the device. A multicolour device status LED visualises the operating states in a user-friendly way. A sealable transparent cover protects the device against unwanted tampering.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo DIN VDE 0100-551 for mobile generators\u003c\/li\u003e\n\u003cli\u003ePreventive fire and plant protection\u003c\/li\u003e\n\u003cli\u003eDetection of symmetrical and asymmetrical insulation faults\u003c\/li\u003e\n\u003cli\u003eUniversally usable in unearthed AC, DC and AC\/DC networks up to max. 300 V\u003c\/li\u003e\n\u003cli\u003eSimple setting of response values and setting parameters using rotary switches\u003c\/li\u003e\n\u003cli\u003eFor network leakage capacitances up to 30 μF\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eMeasuring circuit monitoring L(+)\/L(-) for wire break (can be switched off)\u003c\/li\u003e\n\u003cli\u003eProtective conductor connection monitoring PE1\/PE2 for wire break (cannot be switched off)\u003c\/li\u003e\n\u003cli\u003eNo additional series device required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation monitoring according to IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003e2 separately adjustable response thresholds (e.g. usable for pre-alarm and alarm)\u003c\/li\u003e\n\u003cli\u003eSetting range 1. Response value (pre-alarm): 20 kΩ … 1 MΩ\u003c\/li\u003e\n\u003cli\u003eSetting range 2. Response value (alarm): 10 kΩ … 250 kΩ\u003c\/li\u003e\n\u003cli\u003e2 changeover contact(s) for insulation fault pre-alarm and insulation fault alarm\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit principle adjustable for signalling relay\u003c\/li\u003e\n\u003cli\u003eWith multicolour device status LED to indicate the operating state\u003c\/li\u003e\n\u003cli\u003eAutomatic and manual device self-test\u003c\/li\u003e\n\u003cli\u003eAlarm latching selectable\u003c\/li\u003e\n\u003cli\u003eTamper protection by sealable transparent cover\u003c\/li\u003e\n\u003cli\u003eExternal control input for combined test\/reset button\u003c\/li\u003e\n\u003cli\u003e3 wide-range voltage ranges for the auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eWidth 52.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 - 250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 85 - 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kOhm - 1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUL-listed C\/US, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 - 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor mobile generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RN 5897\/300” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e DC 12 - 24 V; AC\/DC 24 - 60 V; AC\/DC 85 - 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0070149\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRN5897.12\/300\/61 AC\/DC85-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RN5897.12\/300\/61 AC\/DC85-230V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RN5897.12\/300\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0070149 (RN5897.12\/300\/61 AC\/DC85-230V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RN5897.12\/300\/61 AC\/DC85-230V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRN5897.12\/300\/61 AC\/DC85-230V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RN5897.12\/300\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for RN5897.12\/300\/61 AC\/DC85-230V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the RN 5897\/300 product family; the link is in the downloads section below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/87\/63\/63\/1787908040\/RN5897_300_de.pdf?ts=1787908040\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RN 5897\/300 (PDF, 816.67 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/47\/cb\/af\/1788957219\/RN5897_300.zip?ts=1789551111\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro RN 5897\/300 (ZIP, 94.54 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2f\/11\/c0\/1746608063\/Flyer_Isolationswaechter_RN5897_300_F96B.pdf?ts=1788514930\" target=\"_blank\" rel=\"noopener\"\u003eFlyer insulation monitor RN 5897\/300 (PDF, 188.61 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407761969501,"sku":"0070149","price":299.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RN5897_300.jpg?v=1793922679"}],"url":"https:\/\/www.iam24.de\/en\/collections\/dold-rn-5897.oembed","provider":"IAM24","version":"1.0","type":"link"}