{"title":"GMI D2000 series","description":"","products":[{"product_id":"d2010m","title":"D2010M multiplexer systems, intrinsically safe – analogue temperature multiplexer – DIN rail model D2010M","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2010M\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe intrinsically safe multiplexer system of the D2000M series consists of one to four analogue temperature multiplexers of model D2010M, up to twelve expansion units of model D2011M or up to four digital multiplexers of model D2030M. These are installed in hazardous areas of Zones 1–2 (gas group IIC–IIB–IIA T4) or Class I, Division 1–2 (Group A, B, C, D T4) and connected via a redundant 2-wire data line to a Modbus gateway of model D2050M. The gateway is installed in safe areas\/non-hazardous areas and connected to a PLC, a distributed control system (DCS) or a PC. Multiplexers of model D2010M can be installed on site, close to input sensors, to acquire signals from hazardous areas of Zones 0–1–2 or Classes I, II, III, Division 1–2. The devices are primarily intended for acquiring low-level signals in hazardous areas. These signals come from mV, thermocouple, resistance or mA sources (via an external shunt, e.g. the four-channel shunt resistor D1090Q). The D2010M scans all channels with state-of-the-art isolated solid-state relays and stores all data in a memory buffer that the Modbus gateway D2050M can access quickly. Each D2010M unit directly processes up to 16 input channels. By adding one to three D2011M devices, the number of channels can be expanded to 64 in blocks of 16 channels each. Four D2010M devices connected to twelve D2011M expansion units enable 256 inputs with a single Modbus gateway D2050M. Redundant communication is ensured by a dual data\/supply interface. The safety parameters are also compatible with gas group IIC or gas groups A and B in redundant operation. An integrating, highly sensitive and high-precision (18-bit) A\/D converter enables accurate and stable measurements. All parameters can be configured by software via serial commands with the gateway unit D2050M. Functions and serial commands for the RS-232 and RS-485 protocols are described in the operating instructions.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Intrinsically safe for installation in Zone 1, 2, gas group IIC, IIB, IIA T4 or Class I, Division 1, 2, Groups A, B, C, D, temperature code T4 and Class I, Zone 1, 2, Groups IIC, IIB, IIA, temperature code T4 (hazardous areas\/locations).\n\n\n\u003cbr\u003e• Universal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G and Class I, Zone 0, 1, 2, Groups IIC, IIB, IIA (hazardous areas).\n\n\n\u003cbr\u003e• Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to earth allows the use of earthed sensors.\n\n\n\u003cbr\u003e• Expandable to up to 256 analogue channels per system and 31 systems via a single Modbus interface for up to 7936 channels.\n\n\n\u003cbr\u003e• Redundant field cables for communication\/supply.\n\n\n\u003cbr\u003e• High-precision A\/D converter, 18-bit.\n\n\n\u003cbr\u003e• High channel density: 16 channels per unit, 256 channels per system.\n\n\n\u003cbr\u003e• Configurable via the D2050M gateway with the free PC software SWC2090 or user-specific software.\n\n\n\u003cbr\u003e• Modbus output enables savings on PLC\/DCS I\/O card costs.\n\n\n\u003cbr\u003e• Lower costs for wiring, installation and maintenance.\n\n\n\u003cbr\u003e• 1 terminal block per input, no external terminal block required.\u003cbr\u003e\u003cbr\u003e• 16 N. \u003cbr\u003e• DIN rail \u003cbr\u003e• -40...+60 °C","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527973454173,"sku":"D2010M","price":3798.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1170_R00_0877a487-fbec-4507-ba29-ff963b9dc02e.png?v=1772119081"},{"product_id":"d2011m","title":"D2011M multiplexer systems, intrinsically safe, analogue temperature-controlled – multiplexer expander – DIN rail model D2011M","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2011M\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe intrinsically safe multiplexer system of the D2000M series consists of one to four analogue temperature multiplexers (model D2010M), up to twelve expansion units (model D2011M) or up to four digital multiplexers (model D2030M). These are installed in hazardous areas of Zones 1–2 (gas group IIC–IIB–IIA T4) or Class I, Division 1–2 (Group A, B, C, D T4) and connected via a redundant 2-wire data line to a Modbus gateway (model D2050M). The gateway is installed in safe areas\/non-hazardous areas and connected to a PLC, a distributed control system (DCS) or a PC. Multiplexer expansion units (model D2011M) can be installed on site, close to input sensors, to acquire signals from hazardous areas of Zones 0–1–2 (Class I, II, III, Division 1–2). The devices are primarily intended for acquiring low-level signals in hazardous areas. These signals come from mV, thermocouple, resistance or mA sources (via an external shunt, e.g. the four-channel shunt resistor D1090Q). The D2011M scans all channels using state-of-the-art isolated solid-state relays and stores all data in the connected memory buffer of the D2010M. From there, the data can be retrieved quickly via the Modbus gateway D2050M. Each D2011M unit processes up to 16 input channels. An integrating, highly sensitive and high-precision (18-bit) A\/D converter in the D2010M, which controls up to three expanders D2011M, ensures accurate and stable measurements. All parameters can be configured by software via serial commands from the gateway D2050M and are stored in the D2010M unit connected to the expander.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Intrinsically safe for installation in Zone 1, 2, gas group IIC, IIB, IIA T4 or Class I, Division 1, 2, Groups A, B, C, D, temperature code T4 and Class I, Zone 1, 2, Groups IIC, IIB, IIA, temperature code T4 (hazardous areas\/locations).\n\n\n\u003cbr\u003e• Universal inputs (mV, TC, RTD) for Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G and Class I, Zone 0, 1, 2, Groups IIC, IIB, IIA (hazardous areas).\n\n\n\u003cbr\u003e• Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to earth allows operation of earthed sensors.\n\n\n\u003cbr\u003e• High reliability thanks to SMD components.\n\n\n\u003cbr\u003e• High density, 16 channels per unit.\n\n\n\u003cbr\u003e• 1 terminal block per input, no external terminal block required.\u003cbr\u003e\u003cbr\u003e• 16 N. \u003cbr\u003e• DIN rail \u003cbr\u003e• -40...+60 °C","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527973585245,"sku":"D2011M","price":2489.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1544_R00.png?v=1793959542"},{"product_id":"d2030m","title":"D2030M multiplexer systems – intrinsically safe – digital multiplexer – DIN rail model D2030M","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2030M\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe intrinsically safe multiplexer system of the D2000M series consists of one to four analogue temperature multiplexers of model D2010M, up to twelve expansion units of model D2011M or up to four digital multiplexers of model D2030M. These are installed in hazardous areas of Zones 1–2 (gas group IIC–IIB–IIA T4) or Class I, Division 1–2 (Group A, B, C, D T4) and connected via a redundant 2-wire data line to a Modbus gateway of model D2050M. This gateway is installed in safe areas\/non-hazardous areas and connected to a PLC, a distributed control system (DCS) or a PC. Multiplexers of model D2030M can be installed on site, close to input sensors, to acquire signals from hazardous areas of Zones 0–1–2 or Classes I, II, III, Division 1–2. The devices are primarily intended for acquiring volt-free contact or proximity detectors in accordance with EN 60947-5-6 in hazardous areas. The D2030M scans all channels and stores all data in a memory buffer that the Modbus gateway D2050M can access quickly. Each D2030M unit directly processes up to 32 input channels. Four D2030M units provide 128 inputs with a single Modbus gateway D2050M. Redundant communication is ensured by a dual data\/supply interface. The safety parameters are also compatible with gas groups IIC or A and B in redundant operation. All parameters can be configured by software via serial commands of the D2050M gateway. Functions and serial commands for the RS-232 and RS-485 protocols are described in the operating instructions.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Intrinsically safe for installation in Zone 1, 2, gas group IIC, IIB, IIA T4 or Class I, Division 1, 2, Groups A, B, C, D, temperature code T4 and Class I, Zone 1, 2, Groups IIC, IIB, IIA, temperature code T4 (hazardous areas\/locations).\n\n\n\u003cbr\u003e• Inputs from volt-free contacts or proximity sensors according to EN 60947\u003cbr\u003e•5\u003cbr\u003e•6 from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G and Class I, Zone 0, 1, 2, Groups IIC, IIB, IIA (hazardous areas).\n\n\n\u003cbr\u003e• Expandable to up to 128 digital channels per system and 31 systems via a single Modbus interface for up to 3968 channels.\n\n\n\u003cbr\u003e• Redundant field cables for communication\/supply.\n\n\n\u003cbr\u003e• High channel density: 32 channels per unit, 128 channels per system.\n\n\nConfigurable via the D2050M gateway with the free PC software SWC2090 or custom software.\n\n\nModbus output enables cost savings on PLC\/DCS I\/O cards.\n\n\n1 terminal block per input, no external terminal block required.\u003cbr\u003e\u003cbr\u003e• 32 N. \u003cbr\u003e• DIN rail \u003cbr\u003e• -40...+60 °C","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527974764893,"sku":"D2030M","price":2357.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1171_R00_b4e5adf7-bbb8-41bf-bd4e-6c4f274bbd0c.png?v=1772119083"},{"product_id":"d2050m","title":"D2050M multiplexer systems – intrinsically safe – digital multiplexer – DIN rail model D2050M","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2050M\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe intrinsically safe multiplexer system of the D2000M series consists of one to four analogue temperature multiplexers of model D2010M, up to twelve expansion units of model D2011M or up to four digital multiplexers of model D2030M. These are installed in hazardous areas of Zones 1–2 (gas group IIC–IIB–IIA T4) or Class I, Division 1–2 (Group A, B, C, D T4) and connected via a redundant 2-wire data line to a Modbus gateway of model D2050M. This gateway is installed in safe areas\/non-hazardous areas and connected to a PLC, a distributed control system (DCS) or a PC. Multiplexers of model D2030M can be installed on site, close to input sensors, to acquire signals from hazardous areas of Zones 0–1–2 or Classes I, II, III, Division 1–2. The devices are primarily intended for acquiring volt-free contact or proximity detectors in accordance with EN 60947-5-6 in hazardous areas. The D2030M scans all channels and stores all data in a memory buffer that the Modbus gateway D2050M can access quickly. Each D2030M unit directly processes up to 32 input channels. Four D2030M units provide 128 inputs with a single Modbus gateway D2050M. Redundant communication is ensured by a dual data\/supply interface. The safety parameters are also compatible with gas groups IIC or A and B in redundant operation. All parameters can be configured by software via serial commands of the D2050M gateway. Functions and serial commands for the RS-232 and RS-485 protocols are described in the operating instructions.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Intrinsically safe associated apparatus for installation in safe areas\/non-hazardous areas for supplying the multiplexers D2010M, D2011M, D2030M in Zone 1, 2, gas group IIC, IIB, IIA T4 or Class I, Division 1, 2, Groups A, B, C, D, temperature code T4 and Class I, Zone 1, 2, Groups IIC, IIB, IIA, temperature code T4 in hazardous areas.\n\n\n\u003cbr\u003e• Universal inputs (mV, TC, RTD, contact or proximity sensor) via the devices D2010M, D2011M, D2030M from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G and Class I, Zone 0, 1, 2, Groups IIC, IIB, IIA in hazardous areas.\n\n\n\u003cbr\u003e• Expandable to up to 256 analogue\/128 digital channels per system and 31 systems via a single Modbus interface for up to 7936\/3968 channels.\n\n\n\u003cbr\u003e• Redundant field cables for communication\/supply.\n\n\n\u003cbr\u003e• Modbus interface with RTU protocol via redundant RS\u003cbr\u003e•485 interface.\n\n\n\u003cbr\u003e• RS\u003cbr\u003e•232 connection for system configuration.\n\n\n\u003cbr\u003e• Configurable via the free SWC2090 software or user-specific software.\n\n\n\u003cbr\u003e• Modbus output enables savings on PLC\/DCS I\/O card costs.\n\n\n\u003cbr\u003e• Repeatable input contact for hazardous areas or proximity sensor in safe areas via the D2052M unit (relay output) or via the D2053M unit (transistor output).\u003cbr\u003e\u003cbr\u003e• Modbus RTU \u003cbr\u003e• DIN rail \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527975518557,"sku":"D2050M","price":2619.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1172_R00_a11cb1ad-b997-4e4e-9fce-b6af5568e004.png?v=1772119084"},{"product_id":"d2052m","title":"D2052M multiplexer system relay output amplifier – DIN rail model D2052M","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2052M\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe intrinsically safe multiplexer system of the D2000M series consists of one to four analogue temperature multiplexers (model D2010M), up to twelve expansion units (model D2011M) or up to four digital multiplexers (model D2030M). These are installed in hazardous areas of Zone 1-2 (gas group IIC-IIB-IIA T4) or Class I (Division 1-2, Group A, B, C, D T4) and are connected to a Modbus gateway (model D2050M) via a redundant 2-wire data line. The gateway is installed in safe areas and connected to a PLC, a distributed control system (DCS) or a PC. The gateway D2052M is used primarily to transmit the status of proximity sensors or volt-free contacts of devices in hazardous areas to safe areas. When connected to the D2050M unit, the device reproduces the status of each digital input multiplexer D2030M. It is controlled via a dedicated bus by the gateway D2050M. Using this device simplifies the wiring when digital status values are to be reproduced discretely. In addition, it enables these status values to be analysed via Modbus. The D2052M unit has 32 SPDT relay outputs. The repeaters provide the same number of channels as the digital field devices, so that each input unit can be reproduced on an output unit. The assignment between input (field) devices and output devices (safe area\/non-hazardous areas) is made via the D2050M software and corresponding internal settings. The relay output is a changeover contact, which allows the use of NO or NC contacts.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Output amplifier for the digital multiplexer D2030M.\n\n\n\u003cbr\u003e• SPDT relay output signals.\n\n\n\u003cbr\u003e• High channel density: 32 channels per unit, 128 channels per system.\u003cbr\u003e\u003cbr\u003e• 32 N \u003cbr\u003e• DIN rail \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527976206685,"sku":"D2052M","price":1179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1545_R00.png?v=1793959544"},{"product_id":"d2053m","title":"D2053M Multiplexer systems Transistor output amplifier – DIN rail model D2053M","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2053M\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe intrinsically safe multiplexer system of the D2000M series consists of one to four analogue temperature multiplexers (model D2010M), up to twelve expansion units (model D2011M) or up to four digital multiplexers (model D2030M). These are installed in hazardous areas of Zone 1-2 (gas group IIC-IIB-IIA T4) or Class I (Division 1-2, Group A, B, C, D T4) and connected via a redundant 2-wire data line to a Modbus gateway (model D2050M). The gateway is installed in safe areas and connected to a PLC, a distributed control system (DCS) or a PC. The gateway D2053M is used primarily to transmit the status of proximity sensors or volt-free contacts of devices in hazardous areas to safe areas. When connected to the D2050M unit, the unit repeats the status of each digital input multiplexer D2030M. It is controlled via a dedicated bus by the gateway D2050M. Using these devices reduces wiring complexity when digital status values are to be repeated discretely, and additionally enables their analysis via Modbus. The D2053M unit has 32 opto-coupled transistor outputs. The repeaters offer the same number of channels as the digital field devices, so that every input unit can be repeated on an output unit. The assignment between input (field) devices and output devices (safe area\/non-hazardous areas) is made via the software of the D2050M and corresponding internal settings.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Output amplifier for the digital multiplexer D2030M.\n\n\n\u003cbr\u003e• Opto-isolated, volt-free transistor output signals.\n\n\n\u003cbr\u003e• High channel density: 32 channels per unit, 128 channels per system.\u003cbr\u003e\u003cbr\u003e• DIN rail\u003cbr\u003e\u003cbr\u003e• -40...+60 °C\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527976927581,"sku":"D2053M","price":956.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0327_R00_3549145a-2d6b-4a33-9299-b1fb621c952a.jpg?v=1772119083"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/collections\/IMG1171_R00_4c630691-122b-4115-a1a2-2c2f302cab7f.png?v=1793930140","url":"https:\/\/www.iam24.de\/en\/collections\/gmi-serie-d2000.oembed","provider":"IAM24","version":"1.0","type":"link"}