{"title":"GMI D5000 series","description":"\u003cp\u003eThe \u003cstrong\u003eD5000 series\u003c\/strong\u003e from G.M. International (GMI) comprises intrinsically safe galvanic isolation barriers for applications in hazardous areas. At IAM24, these include SIL 3 safety relays, power supplies for the Power Bus, dummy modules and termination boards for process control and safety systems.\u003c\/p\u003e\u003ch2\u003eFeatures according to GMI\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFor SIL 2 and SIL 3 applications to IEC 61508 and IEC 61511, SIL certification by TÜV\u003c\/li\u003e\n\u003cli\u003eHigh packing density of 6 mm per channel\u003c\/li\u003e\n\u003cli\u003eWide-range supply 18–30 V DC, 2.5 kV isolation\u003c\/li\u003e\n\u003cli\u003eCertified operating temperature −40 to +70 °C\u003c\/li\u003e\n\u003cli\u003eMounting individually on DIN rail, with Power Bus system or on termination boards\u003c\/li\u003e\n\u003cli\u003eCertified by more than 15 certification bodies worldwide, including ATEX and IECEx, also for offshore and marine applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eVersions at IAM24\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6;width:35%\"\u003eIsolating barriers, digital\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSwitch amplifiers for switches and proximity switches (e.g. D5030, D5032, D5034, D5036, D5038), digital output drivers (D5040, D5048, D5049)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIsolating barriers, analogue\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eTransmitter power supplies with HART® (D5011, D5014, D5015, D5016), HART® isolating drivers D5020, temperature converters D5072, vibration converter interface D5062, bridge amplifiers for load cells D5263, D5264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSafety relays\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRelay output modules for 5 A or 10 A, predominantly SIL 3, for NE and ND loads, some with line fault detection (D5090 to D5099, D5290 to D5295)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePower supply and accessories\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePower supply D5202S, diagnostic module D5203S, PSD5201, dummy modules D5000D and D5200D\/ENC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTermination boards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eTB and TBE for ABB, Bailey, HIMA, Honeywell, Invensys\/Foxboro, Schneider Modicon, Triconex and Yokogawa, universal GMI boards as well as boards for HART® multiplexers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eUse the filters to narrow down the selection quickly. Our article \u003ca href=\"\/en\/blogs\/news\/gmi-serie-d5000-funktion-und-auswahl\"\u003eGMI D5000 series: function, applications and the right version\u003c\/a\u003e shows which module suits which field signal.\u003c\/p\u003e\u003cp\u003ePrices plus shipping; VAT is shown according to the delivery country. All technical data is from G.M. International (GMI).\u003c\/p\u003e","products":[{"product_id":"d5000d","title":"D5000D dummy and pass-through modules dummy module","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5000D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5000 dummy module is used to connect unused cable cores. It can also be used as a placeholder for future installation expansions.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527977058653,"sku":"D5000D","price":93.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1522_R00.png?v=1793959543"},{"product_id":"d5011d","title":"D5011D intrinsically safe isolators I.S. SIL3 2-wire HART® transmitter power supply","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0124\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5011D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5011 repeater power supply module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It provides an isolated DC supply to operate conventional 2-wire 4-20 mA transmitters in hazardous areas and to pass the current on in an isolated circuit to drive a load in a safe area. The circuit allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4 × 20 mA passive input, source output\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit-proof input and output\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire passive \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527977353565,"sku":"D5011D","price":327.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0620_R00_81dc59c5-6a94-4029-a4c3-7a80a27d9e17.jpg?v=1772119084"},{"product_id":"d5011s","title":"D5011S intrinsically safe isolators I.S. SIL3 2-wire HART® transmitter power supply","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0124\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5011S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5011 repeater power supply module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It provides an isolated DC supply to operate conventional 2-wire 4-20 mA transmitters in hazardous areas and to pass the current on in an isolated circuit to drive a load in a safe area. The circuit allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4 × 20 mA passive input, source output\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit-proof input and output\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• HART©-compatible \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire passive \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527977943389,"sku":"D5011S","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0329_R00_567cb1a4-70ea-4809-89d9-5a9a16d3f4ae.jpg?v=1772119085"},{"product_id":"d5014d","title":"D5014D intrinsically safe isolators I.S. SIL3 2\/4-wire HART® transmitter power supply","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0103\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5014D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5014 repeater power supply module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It provides an isolated DC supply to drive conventional 2-wire 4-20 mA transmitters (active or passive) in hazardous areas and reproduces the current in the isolated circuit to supply a load in the safe area. The module supports duplication of the output current and allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA active\/passive inputs, source\/sink outputs\n\u003cbr\u003e• Output current duplication possible\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit-proof input and output\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire passive \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527978008925,"sku":"D5014D","price":384.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0330_R00_6e3b12f0-ee95-48e1-8070-615c39256eb3.jpg?v=1772119086"},{"product_id":"d5014s","title":"D5014S intrinsically safe isolators I.S. SIL3 2\/4-wire HART® transmitter power supply","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0103\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5014S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5014 repeater power supply module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It provides an isolated DC supply to drive conventional 2-wire 4-20 mA transmitters (active or passive) in hazardous areas and reproduces the current in the isolated circuit to supply a load in the safe area. The module supports duplication of the output current and allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA active\/passive input, source\/sink output\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit-proof input and output\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• HART©-compatible \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire passive \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527978729821,"sku":"D5014S","price":222.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0331_R00_44c1acbb-a62c-4f13-9656-9b6b7d5d42c2.jpg?v=1772119087"},{"product_id":"d5015sk","title":"D5015SK intrinsically safe isolators I.S. SIL2 2\/4-wire HART® transmitter power supply","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0397\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5015SK\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5015 repeater power supply module is a highly integrated analogue input interface suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. It provides an isolated DC supply to drive conventional 2-wire 4-20 mA transmitters (active or passive) in hazardous areas and passes the current on in the isolated circuit to supply a load in the safe area. The circuit allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA active\/passive input, source\/sink output\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit-proof input and output\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• HART©-compatible \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire passive \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Sink mode \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527981416797,"sku":"D5015SK","price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0621_R01_bb96a305-f18b-4159-aa53-b29963f1f078.png?v=1772119093"},{"product_id":"d5015ss","title":"D5015SS intrinsically safe isolators I.S. SIL2 2\/4-wire HART® transmitter power supply","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0397\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5015SS\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5015 repeater power supply module is a highly integrated analogue input interface suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. It provides an isolated DC supply to drive conventional 2-wire 4-20 mA transmitters (active or passive) in hazardous areas and passes the current on in the isolated circuit to supply a load in the safe area. The circuit allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA active\/passive input, source\/sink output\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit-proof input and output\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• HART©-compatible \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire passive \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527982399837,"sku":"D5015SS","price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0622_R01_17547065-ac1e-4285-bc8f-2081aa02be68.png?v=1772119096"},{"product_id":"d5016dk","title":"D5016DK intrinsically safe isolators I.S. SIL3 2-wire active HART® transmitter current amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0553\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5016DK\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5016 current amplifier module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It amplifies an active 2-wire current signal (4–20 mA) in the isolated circuit to drive a load in the safe area. The module allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA source\u003cbr\u003e•Sink output\n\u003cbr\u003e• HART®-compatible\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire active \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527983055197,"sku":"D5016DK","price":468.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0623_R00_a6f1abca-b6a4-4d0f-86c6-f2c26ddcd7b6.png?v=1772119099"},{"product_id":"d5016ds","title":"D5016DS intrinsically safe isolators I.S. SIL3 2-wire active HART® transmitter current amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0553\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5016DS\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5016 current amplifier module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It amplifies an active 2-wire current signal (4–20 mA) in the isolated circuit to drive a load in the safe area. The module allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA source\u003cbr\u003e•Sink output\n\u003cbr\u003e• HART®-compatible\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire active \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527983907165,"sku":"D5016DS","price":485.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0624_R00_0481ceba-2d42-488a-87db-fbade40e6360.png?v=1772119102"},{"product_id":"d5016sk","title":"D5016SK intrinsically safe isolators I.S. SIL3 2-wire active HART® transmitter current amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0553\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5016SK\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5016 current amplifier module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It amplifies an active 2-wire current signal (4–20 mA) in the isolated circuit to drive a load in the safe area. The module allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA source\u003cbr\u003e•Sink output\n\u003cbr\u003e• HART®-compatible\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• HART©-compatible \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire active connection \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527984660829,"sku":"D5016SK","price":329.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0625_R00_a37fe62e-9d00-4aeb-aadb-104e406033f7.png?v=1772119105"},{"product_id":"d5016ss","title":"D5016SS intrinsically safe isolators I.S. SIL3 2-wire active HART® transmitter current amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0553\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5016SS\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5016 current amplifier module is a highly integrated analogue input interface suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It amplifies an active 2-wire current signal (4–20 mA) in the isolated circuit to drive a load in the safe area. The module allows bidirectional communication signals for HART® devices.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4\u003cbr\u003e•20 mA source\u003cbr\u003e•Sink output\n\u003cbr\u003e• HART®-compatible\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• HART©-compatible \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire active connection \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527985316189,"sku":"D5016SS","price":338.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0626_R00_17a4991e-b0f8-4b91-9d10-68e495014f20.png?v=1772119108"},{"product_id":"d5020d","title":"D5020D intrinsically safe isolators I.S. SIL2 HART® isolating driver","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0118\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5020D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5020 isolating driver module is a highly integrated analogue output interface suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. It isolates and transmits a 4-20 mA signal from a controller in the safe area to a load in the hazardous area. It is characterised by high output power combined with a low voltage drop at the input terminals. The circuit allows bidirectional communication signals for HART® positioners. Line and load open circuits\/short circuits are detected: the fault in the field is transmitted directly to the PLC AO (analogue output) and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Output to Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• 4 × 20 mA input and output signal\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load\n\u003cbr\u003e• On-site fault mirroring to the PLC AO\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• HART©-compatible\u003cbr\u003e\u003cbr\u003e• 4–20 mA\u003cbr\u003e\u003cbr\u003e• Source mode\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• 4–20 mA\u003cbr\u003e\u003cbr\u003e• 2-wire passive\u003cbr\u003e\u003cbr\u003e• SIL2\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527986200925,"sku":"D5020D","price":445.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0332_R00_a46771f4-727d-424b-8cee-06c96805414d.jpg?v=1772119107"},{"product_id":"d5020s","title":"D5020S intrinsically safe isolators I.S. SIL2 HART® isolating driver","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0118\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5020S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5020 isolating driver module is a highly integrated analogue output interface suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. It isolates and transmits a 4-20 mA signal from a controller in the safe area to a load in the hazardous area. It is characterised by high output power combined with a low voltage drop at the input terminals. The circuit allows bidirectional communication signals for HART® positioners. Line and load open circuits\/short circuits are detected: the fault in the field is transmitted directly to the PLC AO (analogue output) and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Output to Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 4 × 20 mA input and output signal\n\u003cbr\u003e• HART®-compatible\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load\n\u003cbr\u003e• On-site fault mirroring to the PLC AO\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• HART©-compatible \u003cbr\u003e• 4–20 mA \u003cbr\u003e• Source mode \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 4–20 mA \u003cbr\u003e• 2-wire passive \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527986495837,"sku":"D5020S","price":257.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0333_R00_59396e95-7339-4262-b8ff-b9aa7151e8d6.jpg?v=1772119107"},{"product_id":"d5030d","title":"D5030D intrinsically safe isolators I.S. SIL3 switch\/proximity relay output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0106\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5030D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5030 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to a relay contact in the safe area. The selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. On the two-channel model, the second output can be configured to repeat the second input, duplicate the first input or report a fault on the first input. If required, the output can also be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• High-voltage\/high-current relay output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N.\u003cbr\u003e\u003cbr\u003e• Isolated input\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST relay\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527986594141,"sku":"D5030D","price":231.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0334_R00_fd9ca496-4ba4-4f7a-b6a6-2160ec302eda.jpg?v=1772119108"},{"product_id":"d5030s","title":"D5030S intrinsically safe isolators I.S. SIL3 switch\/proximity relay output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0106\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5030S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5030 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to a relay contact in the safe area. The selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. On the two-channel model, the second output can be configured to repeat the second input, duplicate the first input or report a fault on the first input. If required, the output can also be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• High-voltage\/high-current relay output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST relay\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527986692445,"sku":"D5030S","price":166.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0335_R00_706c29c2-0b8e-48ff-9580-cebdc9c40f9b.jpg?v=1772119109"},{"product_id":"d5031d","title":"D5031D intrinsically safe isolators I.S. SIL3 switch\/proximity transistor output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0107\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5031D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5031 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to an open-collector transistor in the safe area. A selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. On the two-channel model, the second output can be configured to repeat the second input, duplicate the first input or report a fault on the first input. If required, the output can also be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• High-frequency transistor output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N.\u003cbr\u003e\u003cbr\u003e• Isolated input\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-OC\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527986757981,"sku":"D5031D","price":214.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0336_R00_b98ed3d6-aeb8-47cf-b664-5762fd1601df.jpg?v=1772119110"},{"product_id":"d5031s","title":"D5031S intrinsically safe isolators I.S. SIL3 switch\/proximity transistor output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0107\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5031S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5031 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to an open-collector transistor in the safe area. A selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. On the two-channel model, the second output can be configured to repeat the second input, duplicate the first input or report a fault on the first input. If required, the output can also be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• High-frequency transistor output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-OC\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527986954589,"sku":"D5031S","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0337_R00_08abc6bc-6d14-4b8c-82d2-bfa3e3130412.jpg?v=1772119110"},{"product_id":"d5032d","title":"D5032D intrinsically safe isolators I.S. SIL3 switch\/proximity relay output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0108\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5032D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5032 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to a relay contact in the safe area. The selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. On the two-channel model, the second output can be configured to repeat the second input, duplicate the first input or report a fault on the first input. If required, the output can also be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N.\u003cbr\u003e\u003cbr\u003e• Isolated input\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST relay\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527987544413,"sku":"D5032D","price":227.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0338_R00_6c11c27d-aa04-48a3-acd0-595b0c67afdc.jpg?v=1772119111"},{"product_id":"d5032s","title":"D5032S intrinsically safe isolators I.S. SIL3 switch\/proximity relay output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0108\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5032S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5032 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to a relay contact in the safe area. The selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. On the two-channel model, the second output can be configured to repeat the second input, duplicate the first input or report a fault on the first input. If required, the output can also be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST relay\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527987708253,"sku":"D5032S","price":158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0339_R00_259b03ec-b45c-44a1-a9c1-1c0e16f837db.jpg?v=1772119112"},{"product_id":"d5034d","title":"D5034D intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0113\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5034D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5034 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be connected to switches or proximity detectors in the hazardous area and passes the input current on to the output in the safe area. DCS\/PLC digital input cards compatible with NAMUR devices can detect the status\/fault of proximity sensors or switches with end-of-line resistors in transparent mode via the module.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3\/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• On-site fault mirroring to PLC NAMUR DI\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density: two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• 0.1–8 mA \u003cbr\u003e• Resistance \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 0.1–8 mA \u003cbr\u003e• Sink mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527988887901,"sku":"D5034D","price":293.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0341_R00_81497970-5c27-487d-b4b3-dda0cd0c6798.jpg?v=1772119114"},{"product_id":"d5034s","title":"D5034S intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0113\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5034S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5034 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The device can be connected to switches or proximity detectors in the hazardous area and passes the input current on to the output in the safe area. DCS\/PLC digital input cards compatible with NAMUR devices can detect the status\/fault of proximity sensors or switches with end-of-line resistors in transparent mode via the module.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3\/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• On-site fault mirroring to PLC NAMUR DI\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 0.1–8 mA \u003cbr\u003e• Resistance \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• 0.1–8 mA \u003cbr\u003e• Sink mode \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527989182813,"sku":"D5034S","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0340_R00_e1c8dd1a-6810-40de-9b7a-a7f773109081.jpg?v=1772119114"},{"product_id":"d5036d","title":"D5036D intrinsically safe isolators I.S. SIL2 switch\/proximity relay output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0269\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5036D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5036 switch\/proximity detector repeater is a module suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to a relay contact in the safe area. A selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. If required, the output can be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• High-voltage\/high-current relay output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High packing density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• 1.2–2.1 mA \u003cbr\u003e• Resistance \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• Volt-free SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527989510493,"sku":"D5036D","price":196.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0342_R00_c3430d70-800c-4a29-826d-5851daa70446.jpg?v=1772119115"},{"product_id":"d5036s","title":"D5036S intrinsically safe isolators I.S. SIL2 switch\/proximity relay output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0269\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5036S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5036 switch\/proximity detector repeater is a module suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The device can be configured for switches or proximity detectors in the hazardous area and passes the input state on to a relay contact in the safe area. A selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. If required, the output can be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• High-voltage\/high-current relay output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST relay\u003cbr\u003e\u003cbr\u003e• SIL2\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527990133085,"sku":"D5036S","price":146.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0920_R01_774200e2-abd5-48f6-8c55-ef55d44ce5fd.png?v=1772119121"},{"product_id":"d5037d","title":"D5037D intrinsically safe isolators I.S. SIL2 switch\/proximity transistor output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0270\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5037D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5037 switch\/proximity detector repeater is a module suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and passes the input state on to an open-collector transistor in the safe area. A selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. If required, the output signal can be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• High-frequency transistor output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• 1.2–2.1 mA \u003cbr\u003e• Resistance \u003cbr\u003e• -40…+70 °C \u003cbr\u003e• Volt-free SPST-OC \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527990722909,"sku":"D5037D","price":181.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0343_R00_b390365c-9fad-44c3-8be6-49bc339e9145.jpg?v=1772119118"},{"product_id":"d5037s","title":"D5037S intrinsically safe isolators I.S. SIL2 switch\/proximity transistor output amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0270\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5037S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5037 switch\/proximity detector repeater is a module suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and passes the input state on to an open-collector transistor in the safe area. A selectable fault detection circuit is available for proximity sensors or switches with end-of-line resistors. If required, the output signal can be inverted.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• High-frequency transistor output\n\u003cbr\u003e• Field-side open-circuit and short-circuit detection\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-OC\u003cbr\u003e\u003cbr\u003e• SIL2\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527991312733,"sku":"D5037S","price":134.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0879_R01_fc74697c-3b6d-4179-8dec-5532b9cecc34.png?v=1772119124"},{"product_id":"d5038da","title":"D5038DA intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038DA\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N.\u003cbr\u003e\u003cbr\u003e• Isolated input\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527992000861,"sku":"D5038DA","price":238.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0627_R01_3245f42c-0dec-4e3e-820d-20dedfaaa851.png?v=1772119127"},{"product_id":"d5038db","title":"D5038DB intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038DB\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N.\u003cbr\u003e\u003cbr\u003e• Isolated input\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527992656221,"sku":"D5038DB","price":238.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0628_R01_3c5f8581-1fe4-4a60-ac4a-4563f993a452.png?v=1772119130"},{"product_id":"d5038dc","title":"D5038DC intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038DC\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N.\u003cbr\u003e\u003cbr\u003e• Isolated input\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527996916061,"sku":"D5038DC","price":238.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0899_R01_be1b073f-d338-4af1-bf21-44507c176c41.png?v=1772119133"},{"product_id":"d5038dd","title":"D5038DD intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038DD\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N.\u003cbr\u003e\u003cbr\u003e• Isolated input\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527997702493,"sku":"D5038DD","price":238.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0882_R01_d653070a-12a6-4949-b7e5-01c7a2b0eafc.png?v=1772119139"},{"product_id":"d5038sa","title":"D5038SA intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038SA\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527998357853,"sku":"D5038SA","price":156.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0629_R01_9a25f5d5-73a7-44ad-8a6b-7912ec55d7f5.png?v=1772119142"},{"product_id":"d5038sb","title":"D5038SB intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038SB\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527999111517,"sku":"D5038SB","price":156.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0630_R01_ac2ceae6-700c-47e4-aade-436ce79d80e9.png?v=1772119145"},{"product_id":"d5038sc","title":"D5038SC intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038SC\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527999832413,"sku":"D5038SC","price":156.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0883_R01_79e669a6-16ef-478a-9f9f-a0b83d5c6ede.png?v=1772119148"},{"product_id":"d5038sd","title":"D5038SD intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038SD\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528000553309,"sku":"D5038SD","price":156.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0884_R01_4d3ea5c1-a3e9-468d-843c-d5bad93fabff.png?v=1772119151"},{"product_id":"d5038xa","title":"D5038XA intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038XA\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Duplication\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528001831261,"sku":"D5038XA","price":173.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0631_R01_a0b84231-9fb5-4649-b25b-845649d9bce4.png?v=1772119154"},{"product_id":"d5038xb","title":"D5038XB intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038XB\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Duplication\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528002584925,"sku":"D5038XB","price":173.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0632_R01_24231064-ce54-4522-86f6-ce864da5c425.png?v=1772119157"},{"product_id":"d5038xc","title":"D5038XC intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038XC\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Duplication\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528003207517,"sku":"D5038XC","price":173.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0900_R01_0436b3aa-a015-4d82-b737-2b18295f52e6.png?v=1772119163"},{"product_id":"d5038xd","title":"D5038XD intrinsically safe isolators I.S. SIL3 line fault transfer switch\/proximity amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0427\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5038XD\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5038 switch\/proximity detector repeater is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. The module can be configured for switches or proximity detectors in the hazardous area and reproduces the input state at the output in the safe area. The output can assume two different impedance values (RL or RH) or be completely open. The module output reproduces the input state as follows: low input state -\u0026gt; RL, high input state -\u0026gt; RH. Alternatively, the output can be configured to invert the input state. In both cases, the output opens as soon as a fault (open circuit or short circuit) occurs at the corresponding input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Field fault detection (open and short circuits)\n\u003cbr\u003e• Universal mirroring of field faults to PLC DI\n\u003cbr\u003e• Transparent line monitoring\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Duplication\u003cbr\u003e\u003cbr\u003e• 1.2–2.1 mA\u003cbr\u003e\u003cbr\u003e• Resistance\u003cbr\u003e\u003cbr\u003e• -40…+70 °C\u003cbr\u003e\u003cbr\u003e• Volt-free SPST-SS relays\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528003928413,"sku":"D5038XD","price":292.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0885_R01_912f4ad6-e1e1-424d-a067-6fedbdc0b204.png?v=1772119165"},{"product_id":"d5040d","title":"D5040D intrinsically safe isolators I.S. SIL3 loop-powered digital output driver","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0187\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5040D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5040 loop-powered digital output driver is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It can drive solenoid valves, visual or audible alarms to warn the plant operator, or other process control devices in the hazardous area with control signals from the safe area. It can also be used as a switchable power supply for measurement or process control devices. Two basic output circuits with different safety parameters are available for each channel, so that most devices on the market can be driven.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Output to Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• Loop supply for NE loads\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528004616541,"sku":"D5040D","price":292.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0344_R02_5c3df133-2525-4dd8-b438-da408e005dda.png?v=1772119169"},{"product_id":"d5040s","title":"D5040S intrinsically safe isolators I.S. SIL3 loop-powered digital output driver","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0187\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5040S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5040 loop-powered digital output driver is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It can drive solenoid valves, visual or audible alarms to warn the plant operator, or other process control devices in the hazardous area with control signals from the safe area. It can also be used as a switchable power supply for measurement or process control devices. Two basic output circuits with different safety parameters are available for each channel, so that most devices on the market can be driven.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Output for Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Loop supply for NE loads\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528005304669,"sku":"D5040S","price":184.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0345_R00_a5e34b03-ea90-481a-98be-f0b740b6bed8.jpg?v=1772119166"},{"product_id":"d5048s","title":"D5048S intrinsically safe isolators I.S. SIL3 loop-powered digital output driver","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0119\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5048S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5048 loop-powered digital output driver is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It can drive solenoid valves, visual or audible alarms to warn the plant operator or other process control devices in the hazardous area with control signals from the safe area. It can also be used as a switchable power supply for measurement or process control devices. The function for detecting line and load open circuits\/short circuits is integrated: with the load switched on, the fault in the field is transmitted directly to the PLC output (DO) and additionally reported by opening the fault output. If required, the output can be switched off via the override input, independent of the input status. Three basic output circuits with different safety parameters are available for each channel, so that most devices on the market can be driven.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Output for Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Loop supply for NE loads\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load\n\u003cbr\u003e• Short-circuit-proof output\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/fault\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• -40...+70 °C\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528006025565,"sku":"D5048S","price":197.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0347_R00_44875e78-e432-4bfb-b039-31416f4cf4f3.jpg?v=1772119167"},{"product_id":"d5049s","title":"D5049S Intrinsically safe isolators I.S. SIL3 bus-powered digital output driver","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0120\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5049S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5049 bus-powered digital output driver is a module suitable for applications with SIL 3 requirements in safety-related systems for high-risk industries. It can drive solenoid valves, visual or audible alarms to warn the plant operator or other process control devices in the hazardous area with control signals from the safe area. It can also be used as a switchable power supply for measurement or process control devices. Detection of line and load breaks\/short circuits is integrated for both loaded and no-load operation: the field fault is transmitted directly to the PLC output (DO) and is additionally signalled by opening the fault output. If required, the output can be switched off via the override input, independent of the input status. Three basic output circuits with different safety parameters are available for each channel, so that most devices on the market can be driven.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Output for Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Bus supply for NE loads\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load\n\u003cbr\u003e• Short-circuit-proof output\n\u003cbr\u003e• On-site programming via DIP switch\n\u003cbr\u003e• Triple port isolation: input\/output\/fault\u003cbr\u003e\u003cbr\u003e• 1 N.\u003cbr\u003e\u003cbr\u003e• Configurable via DIP switch\u003cbr\u003e\u003cbr\u003e• -40...+70 °C\u003cbr\u003e\u003cbr\u003e• SIL3\u003cbr\u003e\u003cbr\u003e• D5000\u003cbr\u003e\u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528006123869,"sku":"D5049S","price":204.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0348_R00_005ebb1f-bd05-494f-bcec-236fc9db6245.jpg?v=1772119168"},{"product_id":"d5062s","title":"D5062S intrinsically safe isolators I.S. SIL2 vibration transducer interface","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0184\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5062S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5062S vibration transducer interface is a highly integrated analogue input interface suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. It provides an isolated DC supply to drive vibration transducers, accelerometers or 2-3-wire sensors in the hazardous area and reproduces the sensor input voltage in a fully isolated circuit in the safe area, to drive vibration monitors or analysers for the control and monitoring of rotating machinery.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Input\/output signal: 0 to –20 V\n\u003cbr\u003e• Broadband signal transmission\n\u003cbr\u003e• On-site programming via DIP switch\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528006189405,"sku":"D5062S","price":416.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0349_R00_94f6e6a8-f9fe-48bd-8c90-085075f22947.jpg?v=1772119169"},{"product_id":"d5072d","title":"D5072D Intrinsically safe isolators I.S. SIL2 Multifunction temperature converter","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0157\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe multifunction temperature converter D5072 receives a low DC voltage signal from millivolt, thermocouple or 2-, 3- or 4-wire resistance\/RTD sensors or a transmitting potentiometer in the hazardous area and converts it, with galvanic isolation, into a signal that drives a load in the safe area. It is suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The output signal can be direct or inverted. A Modbus RTU RS-485 output is available via the bus connection. Cold junction compensation can be programmed as follows: Internal: by an internal PT1000 sensor; Fixed: to a temperature value adjustable by the user; External (remote): external RTD on a terminal strip; External (local): external RTD near the module terminal block; Other: compensation RTD connected to one of the two channels. The module D5072D has a duplicator function that generates two independent outputs from a single input. The output function can be configured as adder, subtractor or low\/high selector. The modules are equipped with an alarm function available via a PhotoMOS output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• mV, TC, 2\/3\/4-wire resistance\/RTD or potentiometer input\n\u003cbr\u003e• Duplication\/inversion\/scaling\/user-defined output\n\u003cbr\u003e• Selectable CJC: internal PT1000, external RTD or fixed\n\u003cbr\u003e• High density, two channels per unit\n\u003cbr\u003e• Monitoring of burnout\/internal\/CJC\/input sensor faults\n\u003cbr\u003e• Alarm output with user-adjustable trip points\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High-precision, µP-controlled A\/D converter\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Modbus RTU \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528006844765,"sku":"D5072D","price":557.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0350_R00_65587c7a-2b65-4a7e-8df6-ae30c2ffc959.jpg?v=1772119170"},{"product_id":"d5072d-087","title":"D5072D-087 intrinsically safe isolators I.S. SIL2 resistance amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0178\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072D-087\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5072-087 resistance amplifier accepts a resistance\/RTD or transmitting potentiometer sensor located in the hazardous area and repeats the resistance with isolation into the safe area. It is suitable for applications requiring SIL 2 in safety-related systems for high-risk industries.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Input for 2\/3\/4-wire resistances\/RTDs or potentiometers\n\u003cbr\u003e• Overheating fault detection\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528007598429,"sku":"D5072D-087","price":557.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0352_R02_c81b2b90-558c-4637-ad8a-a0ef56d1ceaf.png?v=1772119178"},{"product_id":"d5072d-096","title":"D5072D-096 intrinsically safe isolators I.S. SIL2 thermocouple\/mV repeater","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0388\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072D-096\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5072-096 thermocouple\/mV repeater receives a low DC voltage signal from a millivolt or thermocouple sensor in the hazardous area and passes it on in isolated form to a safe area. It is suitable for applications requiring safety integrity level SIL 2 in safety-related systems for high-risk industries. The D5072D-096 module has a duplicator function that generates two independent outputs from a single input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• mV or thermocouple input\n\u003cbr\u003e• Output duplication\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High-precision, µP-controlled A\/D converter\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528009957725,"sku":"D5072D-096","price":557.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0353_R02_0bc4b3be-a52e-434b-81b8-ff9c5c4612a6.png?v=1772119181"},{"product_id":"d5072d-099","title":"D5072D-099 Intrinsically safe isolators I.S. SIL2 Sink-out temperature converter","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0389\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072D-099\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe sink-out temperature converter D5072-099 receives a low DC voltage signal from millivolt, thermocouple, resistance\/RTD or transmitting potentiometer sensors in the hazardous area and converts it, with galvanic isolation, into a signal that drives a load in the safe area. It is suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The output signal can be direct or inverted. A Modbus RTU RS-485 output is available via the bus connection. Cold junction compensation can be programmed as follows: Internal: by an internal PT1000 sensor; Fixed: to a temperature value adjustable by the user; External (remote): external RTD on a terminal strip; External (local): external RTD near the module terminal block; Other: compensation RTD connected to one of the two channels. The module D5072D-099 has a duplicator function that generates two independent outputs from a single input. The output function can be configured as average, subtraction, low\/high or redundancy selection. The modules are equipped with an alarm function available via a solid-state contact output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• mV, TC, 2\/3\/4-wire resistance\/RTD or potentiometer input\n\u003cbr\u003e• Duplication\/inversion\/scaling\/user-defined output\n\u003cbr\u003e• Selectable CJC: internal PT1000, external RTD or fixed\n\u003cbr\u003e• High density, two channels per unit\n\u003cbr\u003e• Monitoring of burnout\/internal\/CJC\/input sensor faults\n\u003cbr\u003e• Alarm output with user-adjustable trip points\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High-precision, µP-controlled A\/D converter\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• Modbus RTU \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528011071837,"sku":"D5072D-099","price":557.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0351_R02_6862f494-42ff-44c8-9015-4fdb009e942a.png?v=1772119183"},{"product_id":"d5072s","title":"D5072S Intrinsically safe isolators I.S. SIL2 Multifunction temperature converter","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0157\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe multifunction temperature converter D5072 receives a low DC voltage signal from millivolt, thermocouple or 2-, 3- or 4-wire resistance\/RTD sensors or a transmitting potentiometer in the hazardous area and converts it, with galvanic isolation, into a signal that drives a load in the safe area. It is suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The output signal can be direct or inverted. A Modbus RTU RS-485 output is available via the bus connection. Cold junction compensation can be programmed as follows: Internal: by an internal PT1000 sensor; Fixed: to a temperature value adjustable by the user; External (remote): external RTD on a terminal strip; External (local): external RTD near the module terminal block; Other: compensation RTD connected to one of the two channels. The module D5072D has a duplicator function that generates two independent outputs from a single input. The output function can be configured as adder, subtractor or low\/high selector. The modules are equipped with an alarm function available via a PhotoMOS output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• mV, TC, 2\/3\/4-wire resistance\/RTD or potentiometer input\n\u003cbr\u003e• Duplication\/inversion\/scaling\/user-defined output\n\u003cbr\u003e• Selectable CJC: internal PT1000, external RTD or fixed\n\u003cbr\u003e• High density, two channels per unit\n\u003cbr\u003e• Monitoring of burnout\/internal\/CJC\/input sensor faults\n\u003cbr\u003e• Alarm output with user-adjustable trip points\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High-precision, µP-controlled A\/D converter\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Modbus RTU \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528011497821,"sku":"D5072S","price":413.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0357_R00_ede70fb1-f784-4819-b6c7-059a71bc91ca.jpg?v=1772119183"},{"product_id":"d5072s-087","title":"D5072S-087 intrinsically safe isolators I.S. SIL2 resistance amplifier","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0178\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072S-087\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5072-087 resistance amplifier accepts a resistance\/RTD or transmitting potentiometer sensor located in the hazardous area and repeats the resistance with isolation into the safe area. It is suitable for applications requiring SIL 2 in safety-related systems for high-risk industries.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Input for 2\/3\/4-wire resistances\/RTDs or potentiometers\n\u003cbr\u003e• Overheating fault detection\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High accuracy\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528012284253,"sku":"D5072S-087","price":413.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0356_R00_9de92ca7-7e86-4dce-bfe4-cac19b8f6b00.jpg?v=1772119183"},{"product_id":"d5072s-096","title":"D5072S-096 intrinsically safe isolators I.S. SIL2 thermocouple\/mV repeater","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0388\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072S-096\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5072-096 thermocouple\/mV repeater receives a low DC voltage signal from a millivolt or thermocouple sensor in the hazardous area and passes it on in isolated form to a safe area. It is suitable for applications requiring safety integrity level SIL 2 in safety-related systems for high-risk industries. The D5072D-096 module has a duplicator function that generates two independent outputs from a single input.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• mV or thermocouple input\n\u003cbr\u003e• Output duplication\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High-precision, µP-controlled A\/D converter\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\n\u003cbr\u003e• High density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528013496669,"sku":"D5072S-096","price":413.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0926_R00_d6c5b785-b4ab-464e-b746-e10414eab1f2.png?v=1772119189"},{"product_id":"d5072s-099","title":"D5072S-099 Intrinsically safe isolators I.S. SIL2 Sink-out temperature converter","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0389\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5072S-099\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe sink-out temperature converter D5072-099 receives a low DC voltage signal from millivolt, thermocouple, resistance\/RTD or transmitting potentiometer sensors in the hazardous area and converts it, with galvanic isolation, into a signal that drives a load in the safe area. It is suitable for applications with SIL 2 requirements in safety-related systems for high-risk industries. The output signal can be direct or inverted. A Modbus RTU RS-485 output is available via the bus connection. Cold junction compensation can be programmed as follows: Internal: by an internal PT1000 sensor; Fixed: to a temperature value adjustable by the user; External (remote): external RTD on a terminal strip; External (local): external RTD near the module terminal block; Other: compensation RTD connected to one of the two channels. The module D5072D-099 has a duplicator function that generates two independent outputs from a single input. The output function can be configured as average, subtraction, low\/high or redundancy selection. The modules are equipped with an alarm function available via a solid-state contact output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Input from Zone 0\/Div. 1\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• mV, TC, 2\/3\/4-wire resistance\/RTD or potentiometer input\n\u003cbr\u003e• Duplication\/inversion\/scaling\/user-defined output\n\u003cbr\u003e• Selectable CJC: internal PT1000, external RTD or fixed\n\u003cbr\u003e• High density, two channels per unit\n\u003cbr\u003e• Monitoring of burnout\/internal\/CJC\/input sensor faults\n\u003cbr\u003e• Alarm output with user-adjustable trip points\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Fully programmable operating parameters\n\u003cbr\u003e• High-precision, µP-controlled A\/D converter\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Modbus RTU \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528014610781,"sku":"D5072S-099","price":413.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0355_R02_c732b076-6481-4efc-92c8-6f3ff1ea0476.png?v=1772119192"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/collections\/IMG0331_R00_eec81e78-f112-4694-8845-77784c9b74a8.jpg?v=1794043677","url":"https:\/\/www.iam24.de\/en\/collections\/gmi-serie-d5000.oembed?page=2","provider":"IAM24","version":"1.0","type":"link"}