{"title":"GMI D1000 series safety relays","description":"\u003cp\u003eSIL 3 safety relays from the GMI D1000 series for DIN rail mounting, including relay output modules with line and load diagnostics.\u003c\/p\u003e","products":[{"product_id":"d1092d","title":"D1092D safety relays SIL 3 relay output module DIN rail model D1092D","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0091\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"product-description\"\u003e\n    \u003ch2\u003eG.M. International D1092D – SIL 3 relay output module (dual-channel)\u003c\/h2\u003e\n    \n    \u003cp\u003e\n        The \u003cstrong\u003eD1092D\u003c\/strong\u003e from G.M. International is a highly reliable, dual-channel relay module for DIN rail mounting. It was developed specifically for switching safety-related circuits up to a level of \u003cstrong\u003eSIL 3\u003c\/strong\u003e in accordance with IEC 61508. \n        The module provides safe isolation between control signals (e.g. from a DCS or PLC) and the load in the field.\n    \u003c\/p\u003e\n\n    \u003ch3\u003eOutstanding features\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHighest safety level:\u003c\/strong\u003e Certified for SIL 3 \/ SC 3 applications – ideal for high-risk industries.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDual-channel flexibility:\u003c\/strong\u003e Two completely independent and isolated channels in a compact 22.5 mm enclosure.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVersatile contact configuration:\u003c\/strong\u003e Each channel offers one SPST contact for “Normally Energized” (NE) loads and one for “Normally De-energized” (ND) loads.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHigh switching capacity:\u003c\/strong\u003e Switches loads up to 5 A (inrush current) or 3 A continuous current at 250 Vac or 120 W at DC.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRobust insulation:\u003c\/strong\u003e Complete galvanic isolation between input and output contacts as well as between the two channels.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eZone 2 installation:\u003c\/strong\u003e Approved for installation in hazardous areas of Zone 2 \/ Division 2.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eTechnical data (excerpt)\u003c\/h3\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n        \u003ctbody\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eInput voltage (nominal)\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC (range 20.4 to 27.6 V DC)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eNumber of channels\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 (completely independent)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMax. contact load\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 A, 250 Vac, 750 VA \/ 3 A, 125 Vdc, 120 W\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eResponse\/release time\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTypically 5 ms \/ 3 ms\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-20 to +60 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eEnclosure dimensions\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWidth 22.5 mm, depth 99 mm, height 114.5 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIL 3, ATEX, IECEx, FM \u0026amp; FM-C, TUV\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\n    \u003ch3\u003eFields of application\u003c\/h3\u003e\n    \u003cp\u003e\n        Typical areas of use for the D1092D are \u003cstrong\u003eemergency shutdown systems (ESD)\u003c\/strong\u003e, fire protection systems and the control of critical valves or motors in the chemical and pharmaceutical industries as well as oil and gas production.\n    \u003c\/p\u003e\n\n    \u003cp style=\"font-size: 0.9em; color: #666; margin-top: 20px;\"\u003e\n        \u003cem\u003eRely on G.M. International for functional safety at the highest level.\u003c\/em\u003e\n    \u003c\/p\u003e\n\u003c\/div\u003e","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527967588701,"sku":"D1092D","price":221.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0616_R00_329731d4-d83a-43dc-9f23-f07a44c82679.jpg?v=1772119071"},{"product_id":"d1092d-069","title":"D1092D-069 safety relays SIL 3 relay output module DIN rail – model D1092D-069","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0101\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092D-069\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe single- and two-channel DIN rail relay outputs D1092S-069 and D1092D-069 are suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk industries. Galvanic isolation is ensured between the input and output contacts and between the two channels of the D1092D-069. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (system-to-system signalling, driving LEDs, etc.).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL3\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• 2 fully independent channels\n\n\n\u003cbr\u003e• 1 SPST normally closed and 1 SPST normally open contacts per channel\n\n\n\u003cbr\u003e• Inrush current: 5 A at 30 V DC \/ 250 V AC\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -20...+60 °C \u003cbr\u003e• Volt-free SPST NO+SPST NC relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527968178525,"sku":"D1092D-069","price":238.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1167_R00_4a7e07b3-2cee-4bbd-aba5-913fc73f4f7b.jpg?v=1772119072"},{"product_id":"d1092s","title":"D1092S safety relays SIL 3 relay output module DIN rail model D1092S","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0091\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D1092S single-channel DIN rail relay module is suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk areas. It provides galvanic isolation between input and output contacts. The module has one SPST contact each for energised (NE) and de-energised (ND) loads. When de-energised, the contacts are closed; when switched de-energised, they are open. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL3\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• One SPST contact each for the NE load and the ND load per channel.\n\n\n\u003cbr\u003e• Inrush current: 5 A at 30 V DC \/ 250 V AC.\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• Volt-free 1+1 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527968833885,"sku":"D1092S","price":141.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0745_R00_3f02fab2-bd39-4087-aad8-9bb3b56cc704.jpg?v=1772119073"},{"product_id":"d1092s-069","title":"D1092S-069 safety relays SIL 3 relay output module DIN rail – model D1092S-069","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0101\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092S-069\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe single- and two-channel DIN rail relay outputs D1092S-069 and D1092D-069 are suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk industries. Galvanic isolation is ensured between the input and output contacts and between the two channels of the D1092D-069. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (system-to-system signalling, driving LEDs, etc.).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL3\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• One SPST normally closed and one SPST normally open contact per channel.\n\n\n\u003cbr\u003e• Inrush current: 5 A at 30 V DC \/ 250 V AC.\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -20...+60 °C \u003cbr\u003e• Volt-free SPST NO+SPST NC relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527969653085,"sku":"D1092S-069","price":156.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1168_R00_c5429bd8-3840-421c-96e8-36c3ba05f755.jpg?v=1772119073"},{"product_id":"d1093s","title":"Safety relays D1093S SIL 3 relay output module with – line and load diagnostics DIN rail mounting – model D1093S","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0093\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1093S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D1093S single-channel DIN rail relay module is suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk industries. It provides galvanic isolation between input and output contacts. The module has one DPST contact for energised (NE) loads and one SPST contact for de-energised (ND) loads. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL2\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• Line and load open-circuit diagnostics in NE and ND states\n\n\n\u003cbr\u003e• DPST contact for NE load and 1 SPST contact for ND load\n\n\n\u003cbr\u003e• 5 A inrush current at 30 V DC \/ 250 V AC\u003cbr\u003e\u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ trip by energising \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -20...+60 °C \u003cbr\u003e• 1 DPST for NE loads \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527970242909,"sku":"D1093S","price":348.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0617_R00_5cddb345-ee69-4ce5-8985-e0159d378f92.jpg?v=1772119074"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/collections\/IMG0745_R00_3f02fab2-bd39-4087-aad8-9bb3b56cc704.jpg?v=1793930000","url":"https:\/\/www.iam24.de\/en\/collections\/gmi-sicherheitsrelais-d1000.oembed","provider":"IAM24","version":"1.0","type":"link"}