{"title":"GMI D5000 series safety relays","description":"\u003cp\u003eSIL 3 safety relays of the GMI D5000 series: relay output modules for 5 A and 10 A loads (NE and ND), some with line and load diagnostics (LFD), variants for 24 V DC, 48 V DC, 110 V DC, 115 V AC and 230 V AC, plus transistor failure detectors.\u003c\/p\u003e","products":[{"product_id":"d5090s","title":"D5090S safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0109\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5090 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. For de-energised (NE) loads, two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: an internal circuit allows testing with drive pulses and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528015692125,"sku":"D5090S","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0363_R01_4ee36052-1e19-476f-bb3d-9311064c3944.png?v=1772119195"},{"product_id":"d5090s-086","title":"D5090S-086 safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0267\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S-086\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5090-086 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. For de-energised loads (NE), two NC contacts are available to isolate the load on both supply lines, plus one NO contact for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: an internal circuit allows testing with drive pulses and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528016937309,"sku":"D5090S-086","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0360_R00_86e70422-5623-403b-8a8b-881f43fa41c5.jpg?v=1772119193"},{"product_id":"d5090s-102","title":"D5090S-102 safety relays SIL3 relay output low-power module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0456\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S-102\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5090-102 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. This model is designed specifically for high functional safety with minimal power consumption and low input voltage. Compatibility with certain double-connector cards (DO cards) with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Low power consumption\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528017527133,"sku":"D5090S-102","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0639_R01_a360c3a6-db91-4463-820a-ff2f82cc9afb.png?v=1772119198"},{"product_id":"d5091s","title":"D5091S safety relays SIL3 relay output module for 5 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0110\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5091S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5091 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, one normally open (NO) and one normally closed (NC) contact are available, optionally with energised or de-energised coil. A service contact is also provided. Thanks to extensive compatibility with various process control systems (DCS\/PLC), precise drive pulse testing is possible through an internal circuit that prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for ND\/F\u0026amp;G loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528017690973,"sku":"D5091S","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0364_R00_d022ffb0-d100-4dfe-8d14-4547a1e48c33.jpg?v=1772119196"},{"product_id":"d5091s-103","title":"D5091S-103 safety relays SIL3 relay output low-power module for 5 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0457\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5091S-103\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5091-103 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, one normally open (NO) and one normally closed (NC) contact are available, optionally with energised or de-energised coil. A service contact is also provided. This model is designed specifically for high functional safety with minimal power consumption and low input voltage. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for ND\/F\u0026amp;G loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low power consumption\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528019820893,"sku":"D5091S-103","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0640_R01_41c48166-7739-48e2-abf3-3ac4d095d940.png?v=1772119204"},{"product_id":"d5093d","title":"D5093D safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0175\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093 module, a transistor output detector for 24\/220 V DC\/V AC, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel signals the presence of a 24 to 220 V AC\/DC input signal at the output by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output). The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• Double galvanically isolated inputs\/outputs\n\u003cbr\u003e• High packing density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528020902237,"sku":"D5093D","price":211.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0359_R00_e9b1efca-2ca1-4f68-b6f7-bf088778333a.jpg?v=1772119202"},{"product_id":"d5093d-tb","title":"D5093D-TB safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0541\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093D-TB\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093-TB module, a 24\/220 V DC\/AC transistor output detector, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel can signal the presence of a 24 to 220 V AC\/DC input signal by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output) at the output. The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• Double galvanically isolated inputs\/outputs\n\u003cbr\u003e• High packing density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528022344029,"sku":"D5093D-TB","price":203.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1128_R00_9c3e7c34-9c25-4fff-8a61-bd4c03c15124.png?v=1772119211"},{"product_id":"d5093s","title":"D5093S safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0175\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093 module, a transistor output detector for 24\/220 V DC\/V AC, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel signals the presence of a 24 to 220 V AC\/DC input signal at the output by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output). The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Two-port isolation, input\/output\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528023195997,"sku":"D5093S","price":132.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0358_R00_a4d2a9a1-39b7-4fe6-a0fe-7dd9faa69219.jpg?v=1772119209"},{"product_id":"d5093s-tb","title":"D5093S-TB safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0541\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093S-TB\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093-TB module, a 24\/220 V DC\/AC transistor output detector, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel can signal the presence of a 24 to 220 V AC\/DC input signal by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output) at the output. The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Two-port isolation, input\/output\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528025751901,"sku":"D5093S-TB","price":128.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1129_R00_a86b83ab-d6b7-4398-84da-f46a68082c88.png?v=1772119217"},{"product_id":"d5094s","title":"D5094S safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0299\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5094S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5094 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for energised (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Broad compatibility with various process control systems (DCS) and programmable logic controllers (PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528026407261,"sku":"D5094S","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0361_R00.jpg?v=1793959541"},{"product_id":"d5094s-104","title":"D5094S-104 safety relays SIL3 low-voltage relay module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0460\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5094S-104\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5094-104 relay module is suitable for switching safety-related circuits up to safety level SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for both de-energised (NE) and dead (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528026833245,"sku":"D5094S-104","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0641_R01_fb498dd0-e62d-4304-8086-d910f7ee0a25.png?v=1772119223"},{"product_id":"d5095s","title":"D5095S safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0300\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5095S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5095 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 NC relay contacts are available, connected in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for both energised (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528028438877,"sku":"D5095S","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0362_R00_a06feb8f-97ae-4b35-851f-e2a7111be7bb.jpg?v=1772119221"},{"product_id":"d5095s-105","title":"D5095S-105 safety relays SIL3 low-voltage relay module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0461\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5095S-105\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5095-105 relay module is suitable for switching safety-related circuits up to safety level SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 NC relay contacts are available, connected first in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for both de-energised (NE) and dead (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low input voltage\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528030077277,"sku":"D5095S-105","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0642_R01_d8f9da3a-3086-47c6-ad78-5d166cd88f9e.png?v=1772119228"},{"product_id":"d5096s","title":"D5096S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0301\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5096 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by an SIL 3 safety function for voltage-free (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Wide compatibility with various process control systems (DCS) and PLCs is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit and open-circuit detection as well as load voltage monitoring are possible both in the de-energised and in the energised state. The fault in the field is transmitted directly to the PLC output DO and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC output\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528034173277,"sku":"D5096S","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0365_R00_1217c712-3780-40af-9bba-29ac6c4d8595.jpg?v=1772119225"},{"product_id":"d5096s-100","title":"D5096S-100 safety relay SIL3\/2 5 A relay with LFD and universal fault mirroring","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0439\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S-100\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5096-100 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by the SIL 3 safety function for voltage-free (NE) loads and SIL 2 for de-energised (ND)\/F\u0026amp;G loads. The load can be isolated from the supply network in both polarities. Wide compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit\/open-circuit detection in the line and load as well as monitoring of the load voltage are possible with the load both energised and de-energised. The fault in the field is mirrored directly to the PLC DO connection by opening the input and is additionally reported by opening the fault output. This fault mirroring technique ensures wide compatibility with PLC DO cards.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for ND loads with ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Universal fault mirroring to the PLC DO\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528035647837,"sku":"D5096S-100","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0372_R00_a7415f01-a3d9-4420-9c14-84ed8609d473.jpg?v=1772119227"},{"product_id":"d5096s-106","title":"D5096S-106 Safety relay SIL3 Low-voltage relay module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0462\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S-106\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5096-106 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by an SIL 3 safety function for both voltage-controlled (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage. Short-circuit and open-circuit detection on line and load as well as load voltage monitoring are integrated in both the de-energised and the energised state. The fault in the field is transmitted directly to the PLC output (DO) and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low input voltage\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC output\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528037253469,"sku":"D5096S-106","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0643_R01_70916b2b-9c88-4a2c-9086-0a9078da891e.png?v=1772119232"},{"product_id":"d5097s","title":"D5097S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0302\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5097S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5097 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has 2+2 NC relay contacts connected in parallel and then in series to avoid false tripping and increase process availability. The SIL 3 safety function ensures high process availability for both voltage-controlled (NE) and voltage-free (ND) loads (F\u0026amp;G). The load can be isolated from the supply in both polarities. Wide compatibility with various DCS\/PLC is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit\/open-circuit detection on line and load as well as monitoring of the load voltage are possible both with the load energised and de-energised. The fault in the field is transmitted directly to the PLC DO output and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC DO\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528038138205,"sku":"D5097S","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0366_R00_268dd28b-7d0e-412e-a226-087208b24564.jpg?v=1772119230"},{"product_id":"d5097s-107","title":"D5097S-107 Safety relay SIL3 Low-voltage relay module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0463\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5097S-107\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5097-107 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 NC relay contacts are available, connected in parallel and then in series. High process availability is ensured by an SIL 3 safety function for both voltage-controlled (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage. Short-circuit\/open-circuit detection in line and load as well as load voltage monitoring are integrated in both the de-energised and the energised state. The fault in the field is transmitted directly to the PLC DO output and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low input voltage\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC DO\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528038859101,"sku":"D5097S-107","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0644_R01_cb3fb2ac-d1d0-4e35-aead-91ba7da082e9.png?v=1772119238"},{"product_id":"d5098d","title":"D5098D safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0305\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5098D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5098 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has normally open (NO) contacts for up to two energised (NE) loads and normally closed (NC) contacts for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528039416157,"sku":"D5098D","price":223.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0369_R00_3c142070-4f8a-429e-91a9-e01cf84668bb.jpg?v=1772119235"},{"product_id":"d5098s","title":"D5098S safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0305\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5098S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5098 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has normally open (NO) contacts for up to two energised (NE) loads and normally closed (NC) contacts for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528040071517,"sku":"D5098S","price":141.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0368_R00_6aedfaca-46b0-46b5-a7d8-fe5cf53c7d9a.jpg?v=1772119236"},{"product_id":"d5099d-108","title":"D5099D-108 safety relay output module for 5 A loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0538\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099D-108\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5099-108 is a relay module with up to two SPDT (single pole double throw) contacts isolated from the input. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Both NC and NO contacts available\n\u003cbr\u003e• Low drive current (\u0026lt; 10 mA)\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528040825181,"sku":"D5099D-108","price":158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0645_R01_c02c8b3e-b333-4549-ac82-365518ac1d31.png?v=1772119243"},{"product_id":"d5099s","title":"D5099S safety relay output module for 5 A loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0394\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5099 is a relay module with one SPDT (single pole double throw) contact isolated from the input. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Both NC and NO contacts available\n\u003cbr\u003e• Low drive current (\u0026lt; 10 mA)\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528041742685,"sku":"D5099S","price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0927_R01_86c59cba-e1ff-4c51-92de-08e474dd1fc1.png?v=1772119245"},{"product_id":"d5099s-108","title":"D5099S-108 safety relay output module for 5 A loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0538\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099S-108\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5099-108 is a relay module with up to two SPDT (single pole double throw) contacts isolated from the input. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Both NC and NO contacts available\n\u003cbr\u003e• Low drive current (\u0026lt; 10 mA)\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528042463581,"sku":"D5099S-108","price":105.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0646_R01_2400c510-312d-459f-9777-079902790f6f.png?v=1772119248"},{"product_id":"d5290s","title":"D5290S safety relays SIL3 relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0111\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: an internal circuit allows testing with drive pulses and prevents contact and LED flickering. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 10 A operating current \/ 16 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528051835229,"sku":"D5290S","price":160.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0381_R00_04dcfd5c-2c09-4e20-ab57-14d7590e017f.jpg?v=1772119266"},{"product_id":"d5290s-078","title":"D5290S-078 safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0152\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-078\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-078 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. Up to four NO contacts and two NC contacts are available, which can be connected externally for several normally energised (NE) or normally de-energised (ND) loads with single- or double-sided disconnection of the supply lines, as well as for additional loads. High compatibility with various distributed control systems (DCS) and programmable logic controllers (PLCs) is ensured: an internal circuit allows testing with control pulses and prevents flickering of contacts and LEDs. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Multiple contacts (up to 4 NE or 2 ND loads)\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 isolated SPST transistors \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528052687197,"sku":"D5290S-078","price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0382_R00_e61bc7ae-a60e-4db1-9e49-4279fcd6a8d8.jpg?v=1772119267"},{"product_id":"d5290s-078-sa","title":"D5290S-078\/SA safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0173\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-078\/SA\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-078\/SA relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has up to four normally open contacts (NO) and two normally closed contacts (NC), which can be connected externally for several energised (NE) or de-energised (ND) loads. One or both supply lines can be isolated and additional loads connected. Compatibility with certain DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE driver\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load disconnection on both supply lines possible\n\u003cbr\u003e• Multiple contacts (up to 3 NE loads)\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPST \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528053473629,"sku":"D5290S-078\/SA","price":139.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0383_R00_35d52a68-fc09-4760-b14b-5ed86c0a8ba6.jpg?v=1772119268"},{"product_id":"d5290s-079","title":"D5290S-079 safety relays SIL3 115 Vac relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0153\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-079\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-079 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has up to four normally open contacts (NO) and two normally closed contacts (NC), which can be connected externally for several energised (NE) or de-energised (ND) loads. One or both supply lines can be isolated and additional loads connected. Compatibility with certain DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE driver\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load disconnection on both supply lines possible\n\u003cbr\u003e• Multiple contacts (up to 4 NE or 2 ND loads)\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• 115 V AC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528054260061,"sku":"D5290S-079","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0384_R00_aad0cc3c-62a3-4e8e-ad92-1739d50827e3.jpg?v=1772119269"},{"product_id":"d5290s-080","title":"D5290S-080 safety relays SIL3 115 V AC relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0151\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-080\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-080 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• 115 V AC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528054423901,"sku":"D5290S-080","price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0385_R00_0fab0c7c-10f7-4e1e-918c-155c2c97a686.jpg?v=1772119270"},{"product_id":"d5290s-084","title":"D5290S-084 safety relays SIL3 110 Vdc relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0170\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-084\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-084 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has up to four normally open contacts (NO) and two normally closed contacts (NC), which can be connected externally for several energised (NE) or de-energised (ND) loads. One or both supply lines can be isolated and additional loads connected. Compatibility with certain DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE driver\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load disconnection on both supply lines possible\n\u003cbr\u003e• Multiple contacts (up to 4 NE or 2 ND loads)\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 110 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528055767389,"sku":"D5290S-084","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0386_R00_792d2f60-117e-40d1-b68d-f3d22d989f4d.jpg?v=1772119270"},{"product_id":"d5290s-091","title":"D5290S-091 safety relays SIL3 230 V AC relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0294\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-091\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-091 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (NE) loads, two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 230 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528056455517,"sku":"D5290S-091","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0391_R00_60c48012-3cdc-4b86-8aad-218ed2a68d3d.jpg?v=1772119271"},{"product_id":"d5290s-092","title":"D5290S-092 safety relays SIL3 48 Vdc relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0372\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-092\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-092 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 48 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528057438557,"sku":"D5290S-092","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0928_R01_900b6072-e917-4dc0-9b17-114cc7aceb6c.png?v=1772119279"},{"product_id":"d5290s-sa","title":"D5290S\/SA safety relays SIL3 relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0150\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S\/SA\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290\/SA relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528057864541,"sku":"D5290S\/SA","price":117.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0395_R00_1321d60b-3654-43e1-acab-b5257e83e012.jpg?v=1772119278"},{"product_id":"d5291s","title":"D5291S safety relays SIL3 relay output module for 10 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0112\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5291S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5291 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, one normally open (NO) and one normally closed (NC) contact are available, optionally with energised or de-energised coil. A service contact is also provided. Thanks to the high compatibility with various process control systems (DCS\/PLC), drive pulse testing is possible, preventing contact and LED flickering. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2 \/ Div. 2\n\u003cbr\u003e• Up to 10 A operating current \/ 16 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528058388829,"sku":"D5291S","price":160.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0396_R00_c5a7afac-d8b2-44eb-9148-ecc19a8ad9c8.jpg?v=1772119279"},{"product_id":"d5291s-097","title":"D5291S-097 safety relays SIL3 48 Vdc relay output module for 10 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0367\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5291S-097\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5291-097 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, it has one normally open (NO) and one normally closed (NC) contact with de-energised coil, plus a service contact. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for ND loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 48 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528058487133,"sku":"D5291S-097","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0868_R01_3b5eb461-72b9-46a8-9368-27fa21406837.png?v=1772119285"},{"product_id":"d5293s","title":"D5293S Safety relay SIL3 Relay output module for 5 A NE loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0122\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5293S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5293 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (NE) loads, two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. The load can be isolated from the supply in both polarities. High compatibility with various distributed control systems (DCS) and programmable logic controllers (PLC) is ensured: an internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit and open-circuit detection as well as load voltage monitoring are possible both when idle and in operation. Faults in the field are transmitted directly to the PLC output (DO) and additionally reported by opening the fault output. Diagnostic parameters are programmable and can be monitored and configured via Modbus.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for fault outputs\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC output\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ drive to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 1+1 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528059076957,"sku":"D5293S","price":477.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0390_R00_249441f0-04f5-422c-8c8e-220004863be2.jpg?v=1772119283"},{"product_id":"d5294s","title":"D5294S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0123\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5294S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5294 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by the SIL 3 safety function for voltage-free (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Wide compatibility with various DCS\/PLCs is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit and open-circuit detection as well as load voltage monitoring are possible with the load both energised and de-energised. The fault in the field is transmitted directly to the PLC output DO and additionally reported by opening the fault output. Diagnostic parameters are programmable and can be monitored and configured via Modbus.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for fault outputs\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Earth fault monitoring\n\u003cbr\u003e• Coil integrity monitoring\n\u003cbr\u003e• Mirroring of field faults to the PLC output\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ apply to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528060453213,"sku":"D5294S","price":639.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0387_R00_2dd473ae-7535-415c-9594-30fd5de80a3a.jpg?v=1772119284"},{"product_id":"d5295s","title":"D5295S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0222\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5295S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5295 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has 2+2 NC relay contacts connected in parallel and then in series to avoid false tripping and increase process availability. The SIL 3 safety function ensures high process availability for both voltage-controlled (NE) and voltage-free (ND) loads (F\u0026amp;G). The load can be isolated from the supply in both polarities. Wide compatibility with various DCS\/PLC is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit\/open-circuit detection in the line and load as well as monitoring of the load voltage are possible with the load both energised and de-energised. The fault in the field is transmitted directly to the PLC DO output and additionally reported by opening the fault output. Diagnostic parameters are programmable and can be monitored and configured via Modbus.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for fault outputs\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Earth fault monitoring\n\u003cbr\u003e• Coil integrity monitoring\n\u003cbr\u003e• Mirroring of field faults to the PLC output\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528061272413,"sku":"D5295S","price":639.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0388_R00_d42a8119-cbab-4c93-83e5-093bd61c9750.jpg?v=1772119285"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/collections\/IMG0381_R00_04dcfd5c-2c09-4e20-ab57-14d7590e017f.jpg?v=1793929999","url":"https:\/\/www.iam24.de\/en\/collections\/gmi-sicherheitsrelais-d5000.oembed","provider":"IAM24","version":"1.0","type":"link"}