{"title":"GMI X1 series safety relays","description":"\u003cp\u003eRelay output modules of the GMI X1 series for 2 A loads (ND, NE and F\u0026amp;G) with SIL 2 and SIL 3 – as electromechanical relay or solid-state relay, some with diagnostic function.\u003c\/p\u003e","products":[{"product_id":"x1-nis-rlo-em-01-s","title":"X1-NIS-RLO\/EM-01-S safety relays SIL3 electromagnetic relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-01-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/EM-01 electromagnetic relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528236089693,"sku":"X1-NIS-RLO\/EM-01-S","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_08b2e89c-a2ff-489c-88aa-34c60aadc62b.jpg?v=1793959382"},{"product_id":"x1-nis-rlo-em-02-s","title":"X1-NIS-RLO\/EM-02-S safety relays SIL2 electromagnetic relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-02-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/EM-02 electromagnetic relay module is suitable for switching safety-related circuits up to SIL 2 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Two-port isolation, input\/output\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL2 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528236712285,"sku":"X1-NIS-RLO\/EM-02-S","price":88.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_ec97aeb6-204b-475a-a56a-0ac043f43ea1.jpg?v=1772119542"},{"product_id":"x1-nis-rlo-em-03-s","title":"X1-NIS-RLO\/EM-03-S safety relays SIL3 electromagnetic relay output module for 2A ND\/F\u0026G loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-03-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/EM-03 electromagnetic relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for normally de-energised (ND) or fire and gas (F\u0026amp;G) loads. Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528237203805,"sku":"X1-NIS-RLO\/EM-03-S","price":151.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_e946a869-1818-4c59-9141-f0af3b366dab.jpg?v=1772119543"},{"product_id":"x1-nis-rlo-em-04-s","title":"X1-NIS-RLO\/EM-04-S Safety relay SIL3 Electromagnetic relay output module for 2A NE loads with diagnostic function","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-04-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe electromagnetic relay module X1-NIS-RLO\/EM-04 is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and supplies a safety normally open contact (NO) for energised (NE) loads. Wide compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit enables testing of drive pulses, prevents flickering of contacts and LEDs and at the same time offers an acceptable resistance for the DO card. Short-circuit and open-circuit detection for lines and loads with programmable limit values as well as load voltage monitoring are possible both when idle and in operation. The fault in the field is passed on directly to the DO switch of the PLC by artificially increasing the input impedance without commutating the relay contacts, and added to the cumulative fault report. To simplify maintenance, field devices can be isolated via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load (programmable thresholds)\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Field fault mirroring to the DCS\/PLC DO card\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPST \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528237859165,"sku":"X1-NIS-RLO\/EM-04-S","price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_0cb80f82-30f7-4a36-bab9-83300f49a202.jpg?v=1772119544"},{"product_id":"x1-nis-rlo-em-05-s","title":"X1-NIS-RLO\/EM-05-S Safety relay SIL3 Electromagnetic relay output module for 2A ND\/F\u0026G loads with diagnostic function","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-05-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe electromagnetic relay module X1-NIS-RLO\/EM-05 is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and supplies a safety normally open contact (NO) for de-energised (ND) or gas and fire protection (F\u0026amp;G) loads. Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. Short-circuit and open-circuit detection for lines and loads with programmable limit values as well as load voltage monitoring are possible both when idle and in operation. The fault in the field is transmitted directly to the DO switch of the PLC by artificially increasing the input impedance without commutating the relay contacts, and added to the cumulative fault report. To simplify maintenance, field devices can be isolated via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load (programmable thresholds)\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring to the DCS\/PLC DO card\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPST \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528238514525,"sku":"X1-NIS-RLO\/EM-05-S","price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00.jpg?v=1772119545"},{"product_id":"x1-nis-rlo-ss-01-s","title":"X1-NIS-RLO\/SS-01-S safety relays SIL3 solid-state relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-01-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/SS-01 solid-state relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528239137117,"sku":"X1-NIS-RLO\/SS-01-S","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00_07fa3f88-7192-4a0f-b031-b80a3fd155f2.jpg?v=1793959382"},{"product_id":"x1-nis-rlo-ss-02-s","title":"X1-NIS-RLO\/SS-02-S safety relays SIL2 solid-state relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-02-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/SS-02 solid-state relay module is suitable for switching safety-related circuits up to SIL 2 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL2 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528239759709,"sku":"X1-NIS-RLO\/SS-02-S","price":88.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00_d94fb917-2580-4765-bb41-199d98bb209d.jpg?v=1772119546"},{"product_id":"x1-nis-rlo-ss-03-s","title":"X1-NIS-RLO\/SS-03-S safety relays SIL3 solid-state relay output module for 2A ND\/F\u0026G loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-03-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/SS-03 solid-state relay module is suitable for switching safety-related circuits up to safety level SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for normally de-energised (ND) or fire and gas systems (F\u0026amp;G). Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ apply to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528240447837,"sku":"X1-NIS-RLO\/SS-03-S","price":151.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00.jpg?v=1772119547"},{"product_id":"x1-nis-rlo-ss-04-s","title":"X1-NIS-RLO\/SS-04-S Safety relay SIL3 Solid-state relay output module for 2A NE loads with diagnostic function","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-04-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe solid-state relay module X1-NIS-RLO\/SS-04 is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and supplies a safety normally open contact (NO) for energised (NE) loads. Wide compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit enables testing of drive pulses, prevents flickering of contacts and LEDs and at the same time offers an acceptable resistance for the DO card. Short-circuit and open-circuit detection for lines and loads with programmable limit values as well as load voltage monitoring are possible both when idle and in operation. The fault in the field is transmitted directly to the PLC DO card by artificially increasing the input impedance without commutating the relay contacts, and added to the cumulative fault report. To simplify maintenance, field devices can be isolated via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load (programmable thresholds)\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Field fault mirroring to the DCS\/PLC DO card\n\u003cbr\u003e• Automatic TProof test available via gateway\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528240546141,"sku":"X1-NIS-RLO\/SS-04-S","price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00_520ab422-ed3c-46fc-8b4d-ce5a7d79d0fb.jpg?v=1772119548"},{"product_id":"x1-nis-rlo-ss-05-s","title":"X1-NIS-RLO\/SS-05-S Safety relay SIL3 Solid-state relay output module for 2A ND\/F\u0026G loads with diagnostic function","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-05-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe solid-state relay module X1-NIS-RLO\/SS-05 is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and supplies a safety normally open contact (NO) for de-energised (ND) or fire and gas systems (F\u0026amp;G). Wide compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit enables drive pulse testing, prevents flickering of contacts and LEDs and at the same time offers an acceptable resistance to the DO card. Short-circuit and open-circuit detection for lines and loads with programmable limit values as well as load voltage monitoring are possible both when idle and in operation. The fault in the field is transmitted directly to the PLC DO card by artificially increasing the input impedance without commutating the relay contacts, and added to the cumulative fault report. To simplify maintenance, field devices can be isolated via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load (programmable thresholds)\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring to the DCS\/PLC DO card\n\u003cbr\u003e• Automatic TProof test available via gateway\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ apply to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528241234269,"sku":"X1-NIS-RLO\/SS-05-S","price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00_78205925-d363-443e-a465-5da0226648b0.jpg?v=1772119549"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/collections\/IMG1307_R00_94099281-974d-4409-9acc-a95c10310d9d.jpg?v=1793959833","url":"https:\/\/www.iam24.de\/en\/collections\/gmi-sicherheitsrelais-x1.oembed","provider":"IAM24","version":"1.0","type":"link"}