{"title":"Rittal IT cooling (climate control)","description":"\u003cp\u003eRittal IT cooling (climate control) comprises components for cooling and air routing for IT equipment and IT racks. The range includes roof-mounted cooling units for cooling IT equipment, Liquid Cooling Unit LCU CW, condenser unit for LCP DX, fan module for VX IT, TS IT and Blue e+ Hybrid IT chiller, among others.\u003c\/p\u003e\u003cp\u003eThe roof-mounted cooling units provide active single-cabinet cooling for power losses of up to 3 kW with setpoint-dependent control of the server supply air temperature. The fan module for VX IT, TS IT provides active ventilation and can be expanded with additional fans. The vertical partition blocks the air flow to the left and right of the 19\" level for cabinet height 2000 mm.\u003c\/p\u003e","products":[{"product_id":"rittal-sk-3166230-dachluefter-fuer-vx-it-ts-it","title":"Rittal SK 3166.230 roof-mounted fan for VX IT, TS IT, 470x200x470 mm, 200 V - 240 V, 1~","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3166.230 (3166230)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 470 x 200 x 470 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 200 V - 240 V, 1~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966277\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3166.230\u003c\/strong\u003e (roof-mounted fan for VX IT, TS IT; 200 V - 240 V, 1~) has external dimensions of 470 x 200 x 470 mm (W x H x D). Roof-mounted fan for the office environment with very low noise level of 39 dB(A) and high volume flow (free-blowing 1245 to 1345 m³\/h).\u003c\/p\u003e\u003cp\u003eThe roof-mounted fan for VX IT and TS IT is intended for the office environment. It is notable for a very low noise level of 39 dB(A) and a high volume flow (free-blowing 1245 to 1345 m³\/h). The speed-controlled fan adapts its output optimally to actual demand.\u003c\/p\u003e\u003cp\u003eThe roof-mounted fan is pre-assembled and wired ready for connection, and is supplied as a fan unit with speed controller, fixing material and installation and quick-start instructions, without roof plate. The material is painted sheet steel; the protection category is IP 20 to EN 60 529.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal fan with speed controller:\u003c\/strong\u003e Speed-controlled fan for temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSheet steel material:\u003c\/strong\u003e Painted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature range:\u003c\/strong\u003e 5 °C...55 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply included:\u003c\/strong\u003e Fan unit, speed controller, fixing material, instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertificates on file:\u003c\/strong\u003e Declaration of conformity and UL + C-UL (listed).\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eVery quiet and therefore suitable for the office environment\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003eSpeed controller\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003cli\u003eWithout roof plate\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3166230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAreas of use\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003efor the office environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMode of operation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eThe speed-controlled fan adapts its output optimally to actual demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003eSpeed controller\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003cbr\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e200 V - 240 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote on art. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow rate to 950 m³\/h at 40 Pa back pressure when using two ventilated plinth trim panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.3 A\u003cbr\u003eAt 60 Hz: 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003epre-assembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 470 mm\u003cbr\u003eHeight: 200 mm\u003cbr\u003eDepth: 470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMounting cut-out\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth:410 mm\u003cbr\u003eDepth: 410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to EN 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSpeed-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRated power L35 L35\/50 Hz: 30 W\u003cbr\u003eRated power L35 L35\/60 Hz: 30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1,345 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e950 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11.362 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK roof-mounted fan 200-240 V, 50-60 Hz\u003cbr\u003eArt. no. SK 3166.230\u003cbr\u003e**\u003cbr\u003eRoof-mounted fan for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 410x410 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. centrifugal fan, speed controller, fixing material and\u003cbr\u003einstallation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e200-240 V, 1~, 50\/60 Hz\u003cbr\u003eRated power: 30 W at 50\/60 Hz\u003cbr\u003eRated current (max.) at 50\/60 Hz: 0.3 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eAir flow rate free-blowing:\u003cbr\u003e1345 m³\/h, 50\/60 Hz\u003cbr\u003eAir flow at operating point:\u003cbr\u003e950 m³\/h at 40 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point: 39 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm: 470x200x470 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 7035 textured\u003cbr\u003eArt. no. SK 3166.230\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3166.230\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3166.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 470 x 200 x 470 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 3166.230 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3166.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, speed controller, wired ready for connection, incl. fixing material, installation and quick-start instructions, without roof plate.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs a roof plate included in the scope of supply of the roof-mounted fan?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eNo, the roof-mounted fan is supplied without roof plate.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 3166.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9138\/3166230_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377119334749,"sku":"3166230","price":599.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3166230-sk-dachluefter-fuer-vx-it-fuer-den-officebereich.jpg?v=1793628477"},{"product_id":"rittal-sk-3301320-abschottung-vertikal-fuer-vx-it-ts-it","title":"Rittal SK 3301.320 baffle, vertical, for VX IT, TS IT, 210x1915x110 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.320 (3301320)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 210 x 1915 x 110 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e width: 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177504424\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.320\u003c\/strong\u003e (baffle, vertical, for VX IT, TS IT) has external dimensions of 210 x 1915 x 110 mm (W x H x D). For blocking the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e\u003cp\u003eThe vertical baffle for VX IT and TS IT is used to block the air flow to the left and right of the 19\" plane and is designed for enclosure height 2000 mm. It is made of cellular PU foam that is flame-retardant according to UL 94 (HF1), and is finished in anthracite. The baffle is self-adhesive on one side and is part of the accessories for IT cooling.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-adhesive on one side:\u003c\/strong\u003e Version of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCellular PU foam material:\u003c\/strong\u003e Material of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame-retardant according to UL 94:\u003c\/strong\u003e Classification HF1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour anthracite:\u003c\/strong\u003e Colour of the baffle\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSelf-adhesive on one side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCellular PU foam\u003cbr\u003eFlame-retardant according to UL 94 (HF1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAnthracite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSeal between\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLCP and 19\" plane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 210 mm\u003cbr\u003eHeight: 1,915 mm\u003cbr\u003eDepth: 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.335 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39269097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177504424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27189261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Foam rubber, thick, 800 mm rack, baffle, vertical for LCP\u003cbr\u003e**\u003cbr\u003eCellular PU foam, flame-retardant according to UL 94 (HF1) for blocking the air flow to the left and right of the 19\" plane. For enclosure width 800 mm.\u003cbr\u003eLength 1900 mm, self-adhesive\u003cbr\u003ePack of 1\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.320\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3301.320?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 210 x 1915 x 110 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat enclosure height is the vertical baffle designed for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe baffle blocks the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308340573,"sku":"3301320","price":60.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301320-schaumgummi-dick.jpg?v=1793628710"},{"product_id":"rittal-sk-3301370-abschottung-vertikal-fuer-vx-it-ts-it","title":"Rittal SK 3301.370 baffle, vertical, for VX IT, TS IT, 110x1915x110 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.370 (3301370)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 110 x 1915 x 110 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e width: 600 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177542068\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.370\u003c\/strong\u003e (baffle, vertical, for VX IT, TS IT) has external dimensions of 110 x 1915 x 110 mm (W x H x D). For blocking the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e\u003cp\u003eThe vertical baffle for VX IT and TS IT is used to block the air flow to the left and right of the 19\" plane and is designed for enclosure height 2000 mm. It is made of cellular PU foam that is flame-retardant according to UL 94 (HF1), and is finished in anthracite. The baffle is self-adhesive on one side and is part of the accessories for IT cooling.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-adhesive on one side:\u003c\/strong\u003e Version of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCellular PU foam material:\u003c\/strong\u003e Material of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame-retardant according to UL 94:\u003c\/strong\u003e Classification HF1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour anthracite:\u003c\/strong\u003e Colour of the baffle\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSelf-adhesive on one side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCellular PU foam\u003cbr\u003eFlame-retardant according to UL 94 (HF1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAnthracite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSeal between\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLCP and 19\" plane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 110 mm\u003cbr\u003eHeight: 1,915 mm\u003cbr\u003eDepth: 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.619 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.719 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39269097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177542068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27189261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Foam rubber, thick, 600 mm rack, baffle, vertical for LCP\u003cbr\u003e**\u003cbr\u003eCellular PU foam, flame-retardant according to UL 94 (HF1) for blocking the air flow to the left and right of the 19\" plane. For enclosure width 600 mm.\u003cbr\u003eLength 1900 mm, self-adhesive\u003cbr\u003ePack of 1\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.370\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3301.370?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 110 x 1915 x 110 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat enclosure height is the vertical baffle designed for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe baffle blocks the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308373341,"sku":"3301370","price":45.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301370-schaumgummi-dick.jpg?v=1793628710"},{"product_id":"rittal-sk-3301380-abschottung-vertikal-fuer-vx-it-ts-it","title":"Rittal SK 3301.380 baffle, vertical, for VX IT, TS IT, 84x1910x84 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.380 (3301380)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 84 x 1910 x 84 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e width: 600 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177507975\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.380\u003c\/strong\u003e (baffle, vertical, for VX IT, TS IT) has external dimensions of 84 x 1910 x 84 mm (W x H x D). For blocking the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e\u003cp\u003eThe vertical baffle for VX IT and TS IT is used to block the air flow to the left and right of the 19\" plane and is designed for enclosure height 2000 mm. It is made of cellular PU foam that is flame-retardant according to UL 94 (HF1), and is finished in anthracite. The baffle is self-adhesive on one side and is part of the accessories for IT cooling.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-adhesive on one side:\u003c\/strong\u003e Version of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCellular PU foam material:\u003c\/strong\u003e Material of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame-retardant according to UL 94:\u003c\/strong\u003e Classification HF1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour anthracite:\u003c\/strong\u003e Colour of the baffle\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSelf-adhesive on one side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCellular PU foam\u003cbr\u003eFlame-retardant according to UL 94 (HF1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAnthracite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSeal between\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSide panel and 19\" plane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 84 mm\u003cbr\u003eHeight: 1,910 mm\u003cbr\u003eDepth: 84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.402 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.502 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39269097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177507975\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27189261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eFoam rubber, thin, 600 mm rack, baffle, vertical for LCP\u003c\/strong\u003e\u003cbr\u003eCellular PU foam, flame-retardant according to UL 94 (HF1) for blocking the air flow to the left and right of the 19\" plane.\u003cbr\u003eFor enclosure width 600 mm.\u003cbr\u003eLength 1900 mm, self-adhesive\u003cbr\u003ePack of 1\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.380\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3301.380?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 84 x 1910 x 84 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat enclosure height is the vertical baffle designed for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe baffle blocks the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308438877,"sku":"3301380","price":37.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301380-schaumgummi-duenn.jpg?v=1793628710"},{"product_id":"rittal-sk-3301390-abschottung-vertikal-fuer-vx-it-ts-it","title":"Rittal SK 3301.390 baffle, vertical, for VX IT, TS IT, 184x1910x84 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.390 (3301390)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 184 x 1910 x 84 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e width: 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177507999\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.390\u003c\/strong\u003e (baffle, vertical, for VX IT, TS IT) has external dimensions of 184 x 1910 x 84 mm (W x H x D). For blocking the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e\u003cp\u003eThe vertical baffle for VX IT and TS IT is used to block the air flow to the left and right of the 19\" plane and is designed for enclosure height 2000 mm. It is made of cellular PU foam that is flame-retardant according to UL 94 (HF1), and is finished in anthracite. The baffle is self-adhesive on one side and is part of the accessories for IT cooling.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-adhesive on one side:\u003c\/strong\u003e Version of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCellular PU foam material:\u003c\/strong\u003e Material of the baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame-retardant according to UL 94:\u003c\/strong\u003e Classification HF1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour anthracite:\u003c\/strong\u003e Colour of the baffle\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301390\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSelf-adhesive on one side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCellular PU foam\u003cbr\u003eFlame-retardant according to UL 94 (HF1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAnthracite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSeal between\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSide panel and 19\" plane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 184 mm\u003cbr\u003eHeight: 1,910 mm\u003cbr\u003eDepth: 84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.818 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.918 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39269097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177507999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27189261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Foam rubber, thin, 800 mm rack, baffle, vertical for LCP\u003cbr\u003e**\u003cbr\u003eCellular PU foam, flame-retardant according to UL 94 (HF1) for blocking the air flow to the left and right of the 19\" plane.\u003cbr\u003eFor enclosure width 800 mm.\u003cbr\u003eLength 1900 mm, self-adhesive\u003cbr\u003ePack of 1\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.390\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3301.390?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 184 x 1910 x 84 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat enclosure height is the vertical baffle designed for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe baffle blocks the air flow to the left and right of the 19\" plane for enclosure height 2000 mm.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308471645,"sku":"3301390","price":50.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301390-schaumgummi-duenn.jpg?v=1793628710"},{"product_id":"rittal-sk-3301392-luftkanal-fuer-seitliche-luftfuehrung","title":"Rittal SK 3301.392 air duct for lateral air routing","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.392 (3301392)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e TS IT · VX IT · Width: 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177716612\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.392\u003c\/strong\u003e (air duct for lateral air routing) is a genuine Rittal article. For cold air supply to switches with lateral air intake.\u003c\/p\u003e\u003cp\u003eThe air duct for lateral air routing is used to supply cold air to switches with lateral air intake. It improves the air supply to 19\" IT equipment with lateral air routing, is variable in depth and has an integrated membrane grommet that allows cables to be routed through to the rear. The air duct belongs to the Small Cooling Units in the IT cooling range.\u003c\/p\u003e\u003cp\u003eThe air duct is made of painted sheet steel in RAL 9005. The scope of supply includes an adaptor for fixing to 19\" profile rails and a magnetic strip for covering the remaining vertical openings in the air baffle. It can only be mounted on the front 19\" installation level.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePainted sheet steel:\u003c\/strong\u003e material in RAL 9005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptor for 19\" profile rails:\u003c\/strong\u003e Included in the scope of supply for fixing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic strip included:\u003c\/strong\u003e Covers remaining vertical openings in the air baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeveral installation options:\u003c\/strong\u003e TS IT 19\" profile rails, TS IT 19\" mounting frames and 19\" profile rails, standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for TS IT\/VX IT:\u003c\/strong\u003e Enclosure type with width 800 mm\u003c\/li\u003e\n\u003cli\u003eFor improved air supply to 19\" IT equipment with lateral air routing\u003c\/li\u003e\n\u003cli\u003eIntegrated membrane grommet allows cables to be routed through to the rear\u003c\/li\u003e\n\u003cli\u003eVariable depth\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAir duct\u003c\/li\u003e\n\u003cli\u003eAdaptor for fixing to 19\" profile rails\u003c\/li\u003e\n\u003cli\u003eMagnetic strip for covering the remaining vertical openings in the air baffle\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePainted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAir duct\u003cbr\u003eAdaptor for fixing to 19\" profile rails\u003cbr\u003eMagnetic strip for covering the remaining vertical openings in the air baffle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003efor TS IT 19\" profile rails\u003cbr\u003efor TS IT 19\" mounting frames\u003cbr\u003efor 19\" profile rails, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMounting note\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCan only be mounted on the front 19\" installation level\u003cbr\u003eCan only be mounted in the area of the vertical 19\" openings of the air baffle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 2 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: TS IT\u003cbr\u003eVX IT\u003cbr\u003eWidth: 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePCF\/PU (cradle-to-gate)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.9 kg CO2 eq (Cat B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e73269098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177716612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC011217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22410601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.392\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3301.392?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eAir duct, adaptor for fixing to 19\" profile rails, magnetic strip for covering the remaining vertical openings in the air baffle.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhere can the air duct for lateral air routing be mounted?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe air duct can only be mounted on the front 19\" installation level and only in the area of the vertical 19\" openings of the air baffle.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_5640\/3301392_Anleitung_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308537181,"sku":"3301392","price":136.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301392-sk-luftkanal.jpg?v=1793628709"},{"product_id":"rittal-sk-3301800-dachaufbau-kuehlgeraete-zur-kuehlung-von-it","title":"Rittal SK 3301.800 roof-mounted cooling units for cooling IT equipment, 597x417x895 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.800 (3301800)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 597 x 417 x 895 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e External circuit IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177558298\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.800\u003c\/strong\u003e (roof-mounted cooling units for cooling IT equipment) has external dimensions of 597 x 417 x 895 mm (W x H x D). Active single-enclosure cooling for power losses up to 3 kW. Setpoint-dependent control of the server inlet air temperature.\u003c\/p\u003e\u003cp\u003eThe roof-mounted cooling unit for cooling IT equipment is an active single-enclosure cooling solution for power losses up to 3 kW with setpoint-dependent control of the server inlet air temperature. It is intended for cooling IT equipment in IT enclosures installed as stand-alone units in secondary rooms and ensures even air distribution in front of the 19\" level.\u003c\/p\u003e\u003cp\u003eThe total cooling output is 3,200 W (L35 L45, to DIN EN 14511). The unit is made of sheet steel in RAL 7035. The condenser has a hydrophobic RiNano coating, and the condensate evaporation is electric and integrated. A drilling template and air baffle plate are included in the scope of supply.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl of server inlet air temperature:\u003c\/strong\u003e Setting range 20 °C to 25 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet air temperature monitoring:\u003c\/strong\u003e Monitoring function of the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric condensate evaporation:\u003c\/strong\u003e Integrated, wired ready for connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category IP 20:\u003c\/strong\u003e External and internal circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant R134a:\u003c\/strong\u003e Cooling medium specification\u003c\/li\u003e\n\u003cli\u003eEven air distribution in front of the 19\" level\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCondenser with hydrophobic RiNano coating\u003c\/li\u003e\n\u003cli\u003eIntegrated electric condensate evaporation\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eDrilling template\u003c\/li\u003e\n\u003cli\u003eAir baffle plate\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAreas of use\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCooling of IT equipment in IT enclosures installed as stand-alone units in secondary rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMode of operation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eThe unit supports the IT-typical “front-to-back” air routing and controls to the set server inlet air temperature setpoint\u003cbr\u003eThe warm IT exhaust air is drawn into the unit from the rear area of the IT enclosure, cooled and blown back out cold in front of the 19\" level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCondenser with hydrophobic RiNano coating\u003cbr\u003eIntegrated electric condensate evaporation\u003cbr\u003eReady-wired\u003cbr\u003eDrilling template\u003cbr\u003eAir baffle plate\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTotal cooling output to DIN EN 14511\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eTotal cooling output L35 L45: 3,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExternal circuit: 2,000 m³\/h\u003cbr\u003eInternal circuit: 1,450 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnergy efficiency ratio (EER) 50\/60 Hz L35 L35\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCooling coefficient L35 L35 (EER) 50 Hz: 1.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V, 1~, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 10.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug-in terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 597 mm\u003cbr\u003eHeight: 417 mm\u003cbr\u003eDepth: 895 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStarting current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl of server inlet air temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMonitoring\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInlet air temperature monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePermissible operating pressure (p max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e25 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAdjustment range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 °C...25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to EN 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExternal circuit IP 20, internal circuit IP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRefrigerant\/cooling medium\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRefrigerant: R134a\u003cbr\u003eQuantity: 1.2 kg\u003cbr\u003eGlobal Warming Potential (GWP): 1,430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e89 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e98 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84158200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177558298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000855\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**IT roof-mounted cooling unit Rittal TopTherm\u003cbr\u003eArt. no. 3301.800\u003cbr\u003e**\u003cbr\u003eThe unit supports the IT-typical “front to back” air routing and controls to the set server inlet air temperature setpoint. The warm IT exhaust air is drawn into the unit from the rear area of the IT enclosure,\u003cbr\u003ecooled and blown back out cold in front of the 19\" level. It is mounted on the roof of the IT enclosure, where the air volume in the enclosure is cooled. An air baffle plate for routing the air\u003cbr\u003ein front of the 19\" level is included in the scope of supply.\u003cbr\u003eTechnical data of the unit:\u003cbr\u003eUseful cooling output to DIN 3168 L25 L35 3000 watts\u003cbr\u003eRated operational voltage 230 V, 1~, 50 Hz\u003cbr\u003eRated power Pel to DIN 3168 L25 L35 1820 watts\u003cbr\u003eDimensions W x H x D [mm] 597 x 417 x 895\u003cbr\u003eRefrigerant R 134 a\u003cbr\u003eSetting range of server inlet air temperature: +20°C to 25°C\u003cbr\u003eNoise level: 70 dB(A)\u003cbr\u003eAmbient temperature range: +20°C to +45°C\u003cbr\u003eTemperature control and monitoring via\u003cbr\u003eComfortcontroller with two volt-free\u003cbr\u003efault signal outputs, door limit switch connection and\u003cbr\u003econdensate warning\u003cbr\u003eConnection via pluggable terminal strip\u003cbr\u003eProtection category to EN 60 529\/10.91\u003cbr\u003eExternal circuit IP 20\/internal circuit IP 20\u003cbr\u003eWeight 96.6 kg\u003cbr\u003eColour RAL 7035\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.800\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3301.800?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 597 x 417 x 895 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 3301.800 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eExternal circuit IP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3301.800?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eCondenser with hydrophobic RiNano coating, integrated electric condensate evaporation, wired ready for connection, drilling template, air baffle plate, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow does the air routing of the roof-mounted cooling unit for IT equipment work?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe unit supports the IT-typical “front-to-back” air routing. The warm IT exhaust air is drawn into the unit from the rear area of the IT enclosure, cooled and blown back out cold in front of the 19\" level.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 3301.800?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003cli\u003eUK declaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_5408\/3301800_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308995933,"sku":"3301800","price":4249.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301800-it-dachaufbau-kuehlgeraet-nutzkuehlleistung-3000.jpg?v=1793628710"},{"product_id":"rittal-sk-3311363-verfluessigereinheit-fuer-lcp-dx","title":"Rittal SK 3311.363 condenser unit for LCP DX, 2282x480x508 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3311.363 (3311363)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 2282 x 480 x 508 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177716643\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3311.363\u003c\/strong\u003e (condenser unit for LCP DX) has external dimensions of 2282 x 480 x 508 mm (W x H x D). The condenser units are required to operate refrigerant-based LCPs. Depending on the version, the units have the external condenser and fan, or additionally a free cooler. The variant with free cooler is required for the LCP DX\/FC combination variant. The units are suitable for roof and wall mounting.\u003c\/p\u003e\u003cp\u003eThe condenser unit for LCP DX is required to operate refrigerant-based LCPs. Depending on the version, the unit has the external condenser and fan, or additionally a free cooler; the variant with free cooler is required for the LCP DX\/FC combination variant. Suitable for roof and wall mounting, the unit is made of painted sheet steel in RAL 9003 and has a speed-controlled fan.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof and wall mounting:\u003c\/strong\u003e Both mounting methods possible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariant with free cooler:\u003c\/strong\u003e For LCP DX\/FC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed-controlled fan:\u003c\/strong\u003e Temperature control of the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowder-coated and galvanised:\u003c\/strong\u003e Sheet steel surface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBasic unit\u003c\/li\u003e\n\u003cli\u003eIncl. mounting material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3311363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCondenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePowder-coated, galvanised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBasic unit\u003cbr\u003eIncl. mounting material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMax. cooling capacity\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSpeed-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRefrigerant\/cooling medium\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRefrigerant: R410A\u003cbr\u003eCooling medium: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 2,282 mm\u003cbr\u003eHeight: 480 mm\u003cbr\u003eDepth: 508 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTotal cooling capacity\/number of fan modules\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e113 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84189910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177716643\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Condenser 3311.363\u003cbr\u003eWHD (mm) 2282x818x552**\u003cbr\u003eAir-cooled condenser for LCP Rack \/ Inline DX 20 kW (3313.290\/ 3313.390):\u003cbr\u003eAn air-cooled condenser is required to operate the LCP DX 20 kW.\u003cbr\u003eThe speed of the axial fans is controlled via the pressure in the cooling circuit.\u003cbr\u003eThe enclosure is made of powder-coated, galvanised sheet steel.\u003cbr\u003eWith the accessories included in the scope of supply, the condenser can be mounted both horizontally and vertically.\u003cbr\u003eMounting brackets are not included in the scope of supply.\u003cbr\u003eIntegrated main switch.\u003cbr\u003eTechnical data:\u003cbr\u003eNumber of axial fans: 3\u003cbr\u003eAir throughput: max. 7,200 m³\/h\u003cbr\u003eConnection, liquid inlet: 22 mm\u003cbr\u003eConnection, gas outlet: 22 mm\u003cbr\u003ePower supply: 230 V, 1-phase, 50\/60 Hz\u003cbr\u003eMax. connected load: 600 W\u003cbr\u003eRefrigerant: R410A\u003cbr\u003eDimensions (WxHxD): 2282x818x552 mm\u003cbr\u003eNoise level (at 10 metres distance): 45 dB (A)\u003cbr\u003eWeight: 68 kg\u003cbr\u003eColour: RAL 9003\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3311.363\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3311.363?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 2282 x 480 x 508 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3311.363?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBasic unit, incl. mounting material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhen is the variant with free cooler required?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe variant with free cooler is required for the LCP DX\/FC combination variant.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377311748445,"sku":"3311363","price":2421.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3311363-externer-verfluessiger-zur-verwendung-mit-lcp-dx.jpg?v=1793628710"},{"product_id":"rittal-sk-3311380-verfluessigereinheit-fuer-lcp-dx","title":"Rittal SK 3311.380 condenser unit for LCP DX, 3048x1270x1100 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3311.380 (3311380)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 3048 x 1270 x 1100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177811683\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3311.380\u003c\/strong\u003e (condenser unit for LCP DX) has external dimensions of 3048 x 1270 x 1100 mm (W x H x D). The condenser units are required to operate refrigerant-based LCPs. Depending on the version, the units have the external condenser and fan, or additionally a free cooler. The variant with free cooler is required for the LCP DX\/FC combination variant. The units are suitable for roof and wall mounting.\u003c\/p\u003e\u003cp\u003eThe condenser unit for LCP DX is required to operate refrigerant-based LCPs. Depending on the version, the unit has the external condenser and fan, or additionally a free cooler; the variant with free cooler is required for the LCP DX\/FC combination variant. Suitable for roof and wall mounting, the unit is made of painted sheet steel in RAL 9003 and has a speed-controlled fan.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof and wall mounting:\u003c\/strong\u003e Both mounting methods possible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariant with free cooler:\u003c\/strong\u003e For LCP DX\/FC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed-controlled fan:\u003c\/strong\u003e Temperature control of the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowder-coated and galvanised:\u003c\/strong\u003e Sheet steel surface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBasic unit and external condenser unit\u003c\/li\u003e\n\u003cli\u003eIncl. mounting material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3311380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCondenser with free cooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePowder-coated, galvanised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBasic unit and external condenser unit\u003cbr\u003eIncl. mounting material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMax. cooling capacity\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e35 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSpeed-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRefrigerant\/cooling medium\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRefrigerant: R410A\u003cbr\u003eCooling medium: water-glycol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 3,048 mm\u003cbr\u003eHeight: 1,270 mm\u003cbr\u003eDepth: 1,100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTotal cooling capacity\/number of fan modules\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V, 3~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e235 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e290 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84189910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177811683\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Hybrid condenser 3311.380\u003cbr\u003eWHD (mm) 3048x1270x1110**\u003cbr\u003eAir-cooled hybrid condenser for LCP Inline DX 35 kW (3313.460\/480):\u003cbr\u003eTo operate the LCP DX\/FC 35 kW, an air-cooled\u003cbr\u003ehybrid condenser is required.\u003cbr\u003eIn DX and hybrid mode, the speed of the axial fans is controlled via the pressure in the cooling circuit; in pure free cooling mode, it is controlled via the outside temperature.\u003cbr\u003eThe enclosure is made of powder-coated, galvanised sheet steel.\u003cbr\u003eAs delivered, the condenser is only suitable for roof mounting (horizontal).\u003cbr\u003eAny required wall mounting (vertical) must be requested separately.\u003cbr\u003eMounting brackets are not included in the scope of supply.\u003cbr\u003eIntegrated main switch.\u003cbr\u003eTechnical data:\u003cbr\u003eNumber of axial fans: 2\u003cbr\u003eAir throughput: max. 27,200 m³\/h\u003cbr\u003eConnection, liquid inlet: 28 mm\u003cbr\u003eConnection, gas outlet: 35 mm\u003cbr\u003eConnection, water inlet and outlet: 2''\u003cbr\u003ePower supply: 400 V, 3-phase, 50\/60 Hz\u003cbr\u003ePower consumption: 3410 W\u003cbr\u003eRefrigerant: R410A\u003cbr\u003eDimensions (WxHxD): 3.048x1.270x1.110 mm\u003cbr\u003eNoise level (at 10 metres distance): 60 dB (A)\u003cbr\u003eWeight: 285 kg\u003cbr\u003eColour: RAL 9003\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3311.380\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3311.380?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 3048 x 1270 x 1100 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3311.380?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBasic unit and external condenser unit, incl. mounting material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhen is the variant with free cooler required?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe variant with free cooler is required for the LCP DX\/FC combination variant.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377311846749,"sku":"3311380","price":12563.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3311380-externer-hybrid-verfluessiger-zur-verwendung-mit.jpg?v=1793628710"},{"product_id":"rittal-sk-3312081-rueckwaertiger-adapter-fuer-lcp-inline-cw","title":"Rittal SK 3312.081 rear adaptor for LCP Inline CW, 300x2000x200 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3312.081 (3312081)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 300 x 2000 x 200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177951334\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3312.081\u003c\/strong\u003e (rear adaptor for LCP Inline CW) has external dimensions of 300 x 2000 x 200 mm (W x H x D). For closing the gap in the rear area that exists when an LCP Inline is installed.\u003c\/p\u003e\u003cp\u003eThe rear adaptor for LCP Inline CW is used to close the gap in the rear area that exists when an LCP Inline is installed. For optimum air routing and energy-efficient operation, LCP Inline Protruding units are pulled out in front of the server racks. The adaptor is screwed to the rear of the LCP, thus ensuring efficient air routing and a uniform appearance.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePainted sheet steel:\u003c\/strong\u003e material in RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptor with roof plate:\u003c\/strong\u003e Included in the scope of supply including fixing material\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for VX IT:\u003c\/strong\u003e Enclosure type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew fixing on the rear:\u003c\/strong\u003e Mounting on the LCP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdaptor\u003c\/li\u003e\n\u003cli\u003ewith roof plate\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3312081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdaptor\u003cbr\u003ewith roof plate\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 300 mm\u003cbr\u003eHeight: 2,000 mm\u003cbr\u003eDepth: 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84159000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177951334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRear adaptor, 3312.081\u003c\/strong\u003e\u003cbr\u003eRear adaptor, 3312.081 for LCPs CW Inline Protruding SK 3313.530\/560\/570\u003cbr\u003eHeight: 2000 mm\u003cbr\u003eRear adaptor:\u003cbr\u003eFor optimum air routing and energy-efficient\u003cbr\u003eoperation, the LCP Inline Protruding units are pulled out 200 mm in front of the server racks.\u003cbr\u003eTo compensate for the resulting gap in the rear area, the adaptor is screwed to the rear of the\u003cbr\u003eLCP, resulting in efficient air routing and a uniform appearance.\u003cbr\u003eRear adaptor,\u003cbr\u003ePackaging unit consisting of:\u003cbr\u003eAdaptor frame with roof plate, incl. fixing material\u003cbr\u003eDimensions WHD: 300 x 2000 x 200 mm\u003cbr\u003eColour: RAL 7035\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3312.081\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3312.081?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 300 x 2000 x 200 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3312.081?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eAdaptor, with roof plate, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the rear adaptor for LCP Inline CW used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe adaptor closes the gap in the rear area that exists when an LCP Inline is installed. It is screwed to the rear of the LCP.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377311912285,"sku":"3312081","price":474.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3312081-rueckwaertiger-adapter-fuer-lcp-inline-cw-vx-it.jpg?v=1793628709"},{"product_id":"rittal-sk-3312805-dachblech-fuer-dachaufbau-kuehlgeraet-blue-e-it","title":"Rittal SK 3312.805 roof plate for roof-mounted cooling unit Blue e+ IT, for width 800 mm, depth 800 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3312.805 (3312805)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for art. no.:\u003c\/strong\u003e 3312.800 · 3185.730\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT · VX · Width: = 800 mm · Depth: = 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177958401\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3312.805\u003c\/strong\u003e (roof plate for roof-mounted cooling unit Blue e+ IT; for width 800 mm, depth 800 mm) is a genuine Rittal article. For mounting the roof-mounted cooling unit. The cut-out in the roof plate is positioned so that the roof-mounted cooling unit sits centrally on the enclosure.\u003c\/p\u003e\u003cp\u003eThe roof plate for the roof-mounted cooling unit Blue e+ IT is used for mounting the roof-mounted cooling unit. The cut-out in the roof plate is positioned so that the roof-mounted cooling unit sits centrally on the enclosure. It is made of painted sheet steel in RAL 7035 and is part of the accessories for IT cooling.\u003c\/p\u003e\u003cp\u003eFor mounting, use the fixing material of the existing closed roof plate. The electric condensate evaporator cannot be used because of a collision with the 19-inch plane; condensate must be drained via the hose supplied.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentral positioning:\u003c\/strong\u003e Cooling unit sits centrally on the enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePainted sheet steel:\u003c\/strong\u003e material in RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain via hose:\u003c\/strong\u003e Via the hose supplied\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof plate fixing material:\u003c\/strong\u003e Use of the existing closed roof plate\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3312805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePainted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMounting note\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor mounting, use the fixing material of the existing closed roof plate\u003cbr\u003eThe electric condensate evaporator SK 3355.720 cannot be used because of a collision with the 19-inch plane. Condensate must be drained via the hose supplied.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for art. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3312.800, 3185.730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003cbr\u003eVX\u003cbr\u003eWidth: = 800 mm\u003cbr\u003eDepth: = 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e94039910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177958401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000744\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27182405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3312.805\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan the electric condensate evaporator be used with the roof plate?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eNo, the electric condensate evaporator cannot be used because of a collision with the 19-inch plane. Condensate must be drained via the hose supplied.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 3312.805?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/3312805_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377312010589,"sku":"3312805","price":147.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3312805-sk-it-dachblech-fuer-vx.jpg?v=1793628709"},{"product_id":"rittal-sk-3312816-stahlblechtuer-fuer-wandanbau-kuehlgeraet-blue-e-it","title":"Rittal SK 3312.816 sheet steel door for wall-mounted cooling unit Blue e+ IT, 800x2.000 mm (WxH)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3312.816 (3312816)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for art. no.:\u003c\/strong\u003e 3312.810 \/ 3412.810 · 3186.x3x \/ 3486.x3x · 3187.x3x \/ 3487.x3x · 3188.x4x \/ 3488.x4x · 3189.x4x \/ 3489.x4x\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT · VX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177958418\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3312.816\u003c\/strong\u003e (sheet steel door for wall-mounted cooling unit Blue e+ IT) is a genuine Rittal article. For mounting the wall-mounted cooling unit. The cut-out in the door is positioned so that the wall-mounted cooling unit is mounted centrally on the door.\u003c\/p\u003e\u003cp\u003eThe sheet steel door for the wall-mounted cooling unit Blue e+ IT is used for mounting the wall-mounted cooling unit. The cut-out in the door is positioned so that the wall-mounted cooling unit is mounted centrally on the door. The door is made of painted sheet steel in RAL 7035 and is part of the accessories for IT cooling.\u003c\/p\u003e\u003cp\u003eThe scope of supply includes the sheet steel door (rear), a comfort handle for half-cylinder profile with safety lock, and fixing material with closure pieces. Hinges are not included in the scope of supply. The door is suitable for enclosure types VX IT and VX.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentral cut-out:\u003c\/strong\u003e Cooling unit mounted centrally on the door\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort handle included:\u003c\/strong\u003e For half-cylinder profile with safety lock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithout hinges:\u003c\/strong\u003e Fixing material with closure pieces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for VX enclosures:\u003c\/strong\u003e Enclosure types VX IT and VX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePainted sheet steel:\u003c\/strong\u003e material in RAL 7035\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSheet steel door, rear\u003c\/li\u003e\n\u003cli\u003eComfort handle for half-cylinder profile with safety lock 3524 E\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material (with closure pieces, without hinges)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3312816\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePainted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel door, rear\u003cbr\u003eComfort handle for half-cylinder profile with safety lock 3524 E\u003cbr\u003eIncl. fixing material (with closure pieces, without hinges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for art. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3312.810 \/ 3412.810, 3186.x3x \/ 3486.x3x, 3187.x3x \/ 3487.x3x, 3188.x4x \/ 3488.x4x, 3189.x4x \/ 3489.x4x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 800 mm\u003cbr\u003eHeight: 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003cbr\u003eVX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e94039910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177958418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000747\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 8\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000744\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27182405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3312.816\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3312.816?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eSheet steel door (rear), comfort handle for half-cylinder profile with safety lock 3524 E, incl. fixing material (with closure pieces, without hinges).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eAre hinges included in the scope of supply of the sheet steel door?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eNo, hinges are not included in the scope of supply. The fixing material includes closure pieces.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/3312816_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377312207197,"sku":"3312816","price":266.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3312816-sk-it-stahlblechtuer-fuer-vx.jpg?v=1793628709"},{"product_id":"rittal-sk-3312820-luftkanal-fuer-wandanbau-kuehlgeraet-blue-e-it","title":"Rittal SK 3312.820 air duct for Blue e+ IT wall-mounted cooling unit","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3312.820 (3312820)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e Depth: = 800 mm · = 1,000 mm · = 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177944541\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3312.820\u003c\/strong\u003e (air duct for Blue e+ IT wall-mounted cooling unit) is a genuine Rittal article. For cold air supply in front of the 19\" plane in combination with the Blue e+ IT wall-mounted cooling unit.\u003c\/p\u003e\u003cp\u003eThe air duct for the Blue e+ IT wall-mounted cooling unit is used for cold air supply in front of the 19\" plane in combination with the Blue e+ IT wall-mounted cooling unit. It is made of painted sheet steel in RAL 9005 and includes fixing material. It is mounted in the lowest 3 U of the 19\" plane and is suitable for enclosure depths of 800 mm, 1,000 mm and 1,200 mm.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold air supply in front of the 19\" plane:\u003c\/strong\u003e In combination with the wall-mounted cooling unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting in the 19\" plane:\u003c\/strong\u003e In the lowest 3 U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable enclosure depths:\u003c\/strong\u003e 800 mm, 1,000 mm and 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePainted sheet steel:\u003c\/strong\u003e material in RAL 9005\u003c\/li\u003e\n\u003cli\u003eOne air duct for various enclosure depths\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3312820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMounting in the lowest 3 U of the 19\" plane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 482.6 mm\u003cbr\u003eHeight: 3 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDepth: = 800 mm\u003cbr\u003e= 1,000 mm\u003cbr\u003e= 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39269097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177944541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC011444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22410601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3312.820\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3312.820?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich enclosure depths is the air duct suitable for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe air duct is suitable for enclosure depths of 800 mm, 1,000 mm and 1,200 mm.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7878\/3312820_Anleitung_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377312239965,"sku":"3312820","price":436.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3312820-sk-it-luftkanal-fuer-wandkuehlgeraet-3312810-zum.jpg?v=1793628709"},{"product_id":"rittal-sk-3313016-lueftermodul-fuer-lcp-rack-inline-cw","title":"Rittal SK 3313.016 fan module for LCP Rack\/Inline CW","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3313.016 (3313016)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177954458\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3313.016\u003c\/strong\u003e (fan module for LCP Rack\/Inline CW) is a genuine Rittal article. Increased cooling capacity. In addition, redundancy can be achieved or the electrical power consumption reduced.\u003c\/p\u003e\u003cp\u003eThe fan module for LCP Rack\/Inline CW is used to increase the cooling capacity. Installing fan modules in an LCP increases the air flow and thus the cooling capacity of the respective variant. In addition, redundancy can be achieved or the electrical power consumption reduced.\u003c\/p\u003e\u003cp\u003eIf the cooling capacity is sufficient, adding fan modules can be used to create redundancy. By retrofitting fans beyond the required air volume flow, the electrical energy consumption can be reduced, as the fans then run at a lower speed. The noise level of the unit is also significantly reduced.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEC fan in the module:\u003c\/strong\u003e Ready-wired, including fixing material\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSheet steel housing:\u003c\/strong\u003e In RAL 9005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy possible:\u003c\/strong\u003e If cooling capacity is sufficient\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced noise level:\u003c\/strong\u003e Through lower speed when retrofitted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow 1,990 m³\/h:\u003c\/strong\u003e Free-blowing, at a rated power of 500 W\u003c\/li\u003e\n\u003cli\u003eCan be connected during operation\u003c\/li\u003e\n\u003cli\u003eTool-free replacement of the fan modules\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003eEC fan\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3313016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003efor LCP Rack\/Inline CW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMode of operation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstalling fan modules in an LCP increases the air flow and thus the cooling capacity of the respective variant. If the cooling capacity is sufficient, adding fan modules can be used to create redundancy. By retrofitting fans beyond the required air volume flow, the electrical energy consumption can be reduced, as the fans then run at a lower speed. The noise level of the unit is also significantly reduced.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure: sheet steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003eEC fan\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3,780 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1,990 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177954458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**LCP fan module, 3313.016\u003cbr\u003e** for LCP Rack \/ Inline CW 3313.130\/230\/250\/260\/530\/540\/550\/560\/570\/238\/268\/548\/538\/568 3314.130\/230\/250\/260\/530\/540\/542\/550\/560\/570\/238\/268\/548\/538\/568\u003cbr\u003eLCP fan module 3313.016:\u003cbr\u003eThe fan module is suitable for LCP Rack \/ Inline CW.\u003cbr\u003eAdditionally installing fan modules in an LCP increases the\u003cbr\u003eair flow and thus the cooling capacity of the respective variant.\u003cbr\u003eIf the cooling capacity is already sufficient, adding\u003cbr\u003efan modules can be used to create redundancy.\u003cbr\u003eFurthermore, by retrofitting fans beyond the required\u003cbr\u003eair volume flow, the electrical energy consumption can be reduced, as the fans then run at a lower speed.\u003cbr\u003eThe noise level of the unit is also significantly reduced.\u003cbr\u003eThe fans can be replaced during operation, without tools and with minimal\u003cbr\u003etime and effort, without specialist personnel\u003cbr\u003eLCP fan module, packaging unit consisting of:\u003cbr\u003eOne sheet metal housing, including EC fan, ready-wired and with\u003cbr\u003eFixing material\u003cbr\u003eNominal voltage: 200V-277V 1~ N PE 50\/60 Hz\u003cbr\u003eSpeed max.: 3780 min-¹\u003cbr\u003ePower consumption max.: 500 W qV (volume flow) free-blowing: 1990 m³\/h\u003cbr\u003eColour: RAL 9005\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3313.016\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3313.016?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, EC fan, ready-wired, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the purpose of installing additional fan modules in an LCP?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eInstallation increases the air flow and thus the cooling capacity. In addition, redundancy can be achieved or the electrical power consumption reduced.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377312338269,"sku":"3313016","price":440.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3313016-lueftermodul-ul.jpg?v=1793628710"},{"product_id":"rittal-sk-3313610-liquid-cooling-unit-lcu-cw","title":"Rittal SK 3313.610 Liquid Cooling Unit LCU CW, 110x1866,5x756 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3313.610 (3313610)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 110 x 1866.5 x 756 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT 19\" profile rails standard · width: ≥ 800 mm · height: ≥ 2,000 mm · depth: ≥ 1,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177973251\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3313.610\u003c\/strong\u003e (Liquid Cooling Unit LCU CW) has external dimensions of 110 x 1866.5 x 756 mm (W x H x D). The LCU CW essentially consists of an air\/water heat exchanger, fans and the controller. It serves to dissipate heat from network\/server enclosures and thus to effectively cool the components installed in the enclosure.\u003c\/p\u003e\u003cp\u003eThe Liquid Cooling Unit LCU CW essentially consists of an air\/water heat exchanger, fans and the controller. It serves to dissipate heat from network\/server enclosures and thus to effectively cool the components installed in the enclosure. The LCU CW is installed in the network\/server enclosure next to the 19\" level.\u003c\/p\u003e\u003cp\u003eThe heated air is drawn in at the rear third of the enclosure, cooled via the heat exchanger and blown out again at the front of the enclosure. The unit controls the server inlet air temperature and monitors system-relevant parameters. Water is used as the coolant; the water quality is determined by the unit specification.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive monitoring:\u003c\/strong\u003e server outlet\/inlet air temperature, water flow\/return temperature, water flow rate, cooling capacity, fan speed and leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSNMP and RiZone:\u003c\/strong\u003e direct connection via Ethernet and integration into RiZone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMC III sensors:\u003c\/strong\u003e option for connecting a maximum of 16 sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for VX IT:\u003c\/strong\u003e 19\" profile rails standard, width ≥ 800 mm, height ≥ 2,000 mm, depth ≥ 1,000 mm\u003c\/li\u003e\n\u003cli\u003eApprovals including Cyber Security Certificate: additionally IEC CB, declaration of conformity and UL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eEfficient cooling of network\/server enclosures\u003c\/li\u003e\n\u003cli\u003eSpace-saving thanks to installation in the enclosure\u003c\/li\u003e\n\u003cli\u003eControl of server inlet air temperature\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient DC fans\u003c\/li\u003e\n\u003cli\u003eOptimum adaptability thanks to dynamic, continuous control of the chilled water flow rate\u003c\/li\u003e\n\u003cli\u003eFan modules can be replaced during operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 Liquid Cooling Unit CW\u003c\/li\u003e\n\u003cli\u003e1 support element for LCU CW\u003c\/li\u003e\n\u003cli\u003e3 m fabric hose (for condensate drain)\u003c\/li\u003e\n\u003cli\u003e2 angled hose connector 90°\u003c\/li\u003e\n\u003cli\u003e12 screw M5 x 12 self-tapping\/NZ\/TX30\u003c\/li\u003e\n\u003cli\u003e1 female connector strip (7-pole)\u003c\/li\u003e\n\u003cli\u003e1 assembly, installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3313610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRack cooling\u003cbr\u003eCW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMode of operation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eThe LCU CW is installed in the network\/server enclosure next to the 19\" level. The heated air is drawn in at the rear third of the enclosure, cooled via the heat exchanger and blown out again at the front of the enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 Liquid Cooling Unit CW\u003cbr\u003e1 support element for LCU CW\u003cbr\u003e3 m fabric hose (for condensate drain)\u003cbr\u003e2 angled hose connector 90°\u003cbr\u003e12 screw M5 x 12 self-tapping\/NZ\/TX30\u003cbr\u003e1 female connector strip (7-pole)\u003cbr\u003e1 assembly, installation and operating instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eConnection of a maximum of 16 CMC III sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMonitoring\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMonitoring of all system-relevant parameters such as server outlet\/inlet air temperature, water flow\/return temperature, water flow rate, cooling capacity, fan speed and leakage\u003cbr\u003eDirect connection of the device via SNMP over Ethernet\u003cbr\u003eIntegration into RiZone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl of server inlet air temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRefrigerant\/cooling medium\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCoolant: water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRefrigerant\/coolant note\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWater quality in accordance with the unit specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT 19\" profile rails standard\u003cbr\u003eWidth: ≥ 800 mm\u003cbr\u003eHeight: ≥ 2,000 mm\u003cbr\u003eDepth: ≥ 1,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 110 mm\u003cbr\u003eHeight: 1,866.5 mm\u003cbr\u003eDepth: 756 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e90 – 264 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1,500 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated output\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDC fans\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFans replaceable during operation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWater connections\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eG ¾\" male thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePermissible operating pressure (p max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range of cooling medium\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 °C...30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTotal cooling capacity\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUseful cooling capacity L24 (server inlet air temperature) W15: 7.9 kW\u003cbr\u003eUseful cooling capacity L24 (server inlet air temperature) W18: 6.8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e92.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e102.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84186900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177973251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000855\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eSK 3313.610 Liquid Cooling Unit LCU CW\u003c\/strong\u003e\u003cbr\u003eThe unit essentially consists of an air\/water heat exchanger,\u003cbr\u003eDC fans and the controller. It serves to dissipate heat from\u003cbr\u003enetwork\/server enclosures and thus to effectively cool the\u003cbr\u003ecomponents installed in the enclosure.\u003cbr\u003eThe unit is installed at the side next to the 19\" level in a\u003cbr\u003enetwork\/server enclosure or in a security safe. The dimensions allow installation in server enclosures with a width \u0026gt; 800 mm, a\u003cbr\u003edepth \u0026gt; 1000 mm and a height \u0026gt; 2000 mm. Installation can be on the right-hand side or the left-hand side in the enclosure.\u003cbr\u003eThe unit has 3 fan modules, each with 3 DC fans. The fan modules can be replaced during operation. The fan speed\u003cbr\u003eis controlled as standard depending on the\u003cbr\u003etemperature difference between the temperature upstream and downstream of the\u003cbr\u003eheat exchanger.\u003cbr\u003eOptionally, control can also be based on the pressure difference upstream and downstream of the servers. The desired pressure difference is adjustable.\u003cbr\u003eThe heated air is drawn in at the rear third of the enclosure, cooled via the heat exchanger and blown out of the unit at the front face in the front area of the enclosure. The air is routed horizontally. The unit controls the server inlet air temperature. This is individually adjustable.\u003cbr\u003eThe water connections are located on the end face of the unit\u003cbr\u003efacing the rear door of the server enclosure (G ¾\" male thread). The\u003cbr\u003econnections are easily accessible and the piping can be routed\u003cbr\u003eupwards, sideways or downwards in the server enclosure or in the Micro Data Center.\u003cbr\u003eLeakage monitoring is integrated. A sensor installed in the condensate tray detects leaks. The controller issues an\u003cbr\u003ealarm message, and the supply of coolant to the unit is interrupted. All components in the condensate area are made of non-corroding materials.\u003cbr\u003eWith the help of condensate prevention, the amount of\u003cbr\u003econdensate produced when the temperature falls below the dew point can be minimised or completely prevented. This function is activated by default, but can be deactivated. For this purpose, as the dew point is approached, the server inlet air temperature is\u003cbr\u003eraised until it is sufficiently far above the dew point again.\u003cbr\u003eThe unit has a 7-segment display.\u003cbr\u003eThe unit has an NFC interface with an app for\u003cbr\u003eparameterisation.\u003cbr\u003eThe unit has a standard integrated controller for network integration. This monitors and controls the operation of the unit.\u003cbr\u003eSetpoints and alarm thresholds as well as the behaviour in emergency operation can be set within the permissible limits. If the controller fails, an integrated\u003cbr\u003e“fail-safe mode ensures that the unit continues to cool. There is the\u003cbr\u003eoption of choosing whether the unit continues to operate at the fan speed and the\u003cbr\u003ewater volume set at the time of controller failure; alternatively, the fan speed and the flow rate of the coolant can be selected and preset for emergency operation.\u003cbr\u003eThe following interfaces to the controller are accessible from the outside (end face of the unit, top rear):\u003cbr\u003e2 network interfaces, Ethernet to IEEE 802.3 via 10\/100\/1000 Base\u003cbr\u003eT\u003cbr\u003eUSB interface as external memory\u003cbr\u003eUSB C interface for service\u003cbr\u003eAlarm relay as changeover contact 48VDC\/1A\u003cbr\u003eCAN bus connection for 16 sensors of the Rittal CMC III\u003cbr\u003eA software concept for setting and monitoring all technical parameters is integrated as standard.\u003cbr\u003eNetwork interfaces: 2xRJ 45 (switched), each 10\/100\/1000 Mbit\/s\u003cbr\u003eSupported protocols: IPv4 \/ IPv6\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; integrated web server, HTTP, HTTPS, SSL, SSH\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eNTP, TCP\/IP v4 and v6, DHCP, DNS, NTP\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eSyslog, SNMP v1, v2c and v3, traps\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eOPC-UA, Modbus\/TCP, SFTP (update \/ file transfer)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eNFC interface with app for parameterisation\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius connection: yes\u003cbr\u003eUSB port for firmware update \/ data logging function: yes\u003cbr\u003eInitial commissioning \/ mass configuration via predefined CSV file\u003cbr\u003eCAN bus interface: RJ45, for connection of ) pcs. CMC III sensors\u003cbr\u003eCAN sensor types optional: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, airflow, EFD, smoke detector\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003evandalism, differential pressure\u003cbr\u003eAlarm relay: 48V DC\/1A\u003cbr\u003eSerial interface:\u003cbr\u003eRS232 (RJ 12) for LTE unit 7030.571\u003cbr\u003eConformity: CE, UL listed, CB report\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40 °C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature: -20 °C to +70 °C\u003cbr\u003eAmbient temperatures + 5 °C to +50 °C\u003cbr\u003eAmbient humidity: 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003eTechnical data of the unit:\u003cbr\u003eDimensions WxHxD: 110x1866,5x756 mm\u003cbr\u003eCooling capacity: 7.9 kW at 15 °C water flow temperature and 24 °C\u003cbr\u003eserver inlet air temperature\u003cbr\u003eAir flow rate (free-blowing) 1500 m³\/h\u003cbr\u003eRated voltage 90-264V\/1~50\/60 Hz\u003cbr\u003eRated power 0.5 kW\u003cbr\u003eOperating temperature range 10-50 °C\u003cbr\u003eWater connections ¾\" male thread\u003cbr\u003eCoolant: water \/ water\/Antifrogen N\u003cbr\u003eCoolant temperature range 10-30 °C, non-condensing\u003cbr\u003ePermissible pressure, water circuit 1 MPa\u003cbr\u003eFlow rate: 0-20 l\/min\u003cbr\u003eFilling volume: approx. 3 l\u003cbr\u003eNoise level: approx. 73 dB(A); free-standing; distance 1 m\u003cbr\u003eProtection category IP 20\u003cbr\u003eWeight: 53 kg\u003cbr\u003eCE declaration of conformity\u003cbr\u003eApprovals: UL listed\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eThe scope of supply of the unit includes a support rail for\u003cbr\u003efastening in the VX IT network\/server enclosure, and a\u003cbr\u003econdensate drain hose (3 m) with two 90° angled connectors.\u003cbr\u003eMaintenance: easy maintenance of the unit. Easy replacement of the\u003cbr\u003efan assemblies; the controller can be pulled out by means of a drawer.\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3313.610\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3313.610?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 110 x 1866.5 x 756 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 3313.610 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3313.610?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 Liquid Cooling Unit CW, 1 support element for LCU CW, 3 m fabric hose (for condensate drain), 2 angled hose connector 90°, 12 screw M5 x 12 self-tapping\/NZ\/TX30, 1 female connector strip (7-pole), 1 assembly, installation and operating instructions.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich enclosures is the Liquid Cooling Unit LCU CW suitable for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe LCU CW is suitable for enclosure type VX IT with 19\" profile rails standard with width ≥ 800 mm, height ≥ 2,000 mm and depth ≥ 1,000 mm.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 3313.610?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eIEC CB\u003c\/li\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_10237\/3313610_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_15317\/3313610_Systemh_auml_rtung_DE\" target=\"_blank\" rel=\"noopener\"\u003eSystem hardening\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377312436573,"sku":"3313610","price":4247.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3313610-liquid-cooling-unit-lcu-cw.jpg?v=1793628709"},{"product_id":"rittal-sk-3313614-anschlussschlauch","title":"Rittal SK 3313.614 connection hose, length 2.5 m (pack of 2)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3313.614 (3313614)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 2.5 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 2 pieces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177983861\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3313.614\u003c\/strong\u003e (connection hose; length 2.5 m) is a genuine Rittal article and is supplied in packaging units of 2 pieces. Flexible, cuttable connection hose incl. union nut at both ends for connecting the LCP\/LCU to fixed piping.\u003c\/p\u003e\u003cp\u003eThe connection hose is flexible, can be shortened and has a union nut at both ends. It is used to connect the LCP\/LCU to fixed piping and is part of the accessories for IT cooling. The hose is made of NBR on the inside with steel spiral and fabric insert; the operating temperature range is -30 °C to 70 °C.\u003c\/p\u003e\u003cp\u003eThe flexible hosing can compensate for dimensional deviations and decouples the LCP from the on-site piping. Two detachable half-shells allow the length of the hose to be shortened individually. The hydraulic hoses are resistant to water and antifreeze.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNBR inside:\u003c\/strong\u003e With steel spiral and fabric insert\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnion nut at both ends:\u003c\/strong\u003e For connection to fixed piping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCuttable length:\u003c\/strong\u003e Via two detachable half-shells\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature range:\u003c\/strong\u003e -30 °C to 70 °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3313614\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRack cooling\u003cbr\u003eCW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNBR (inside) with steel spiral and fabric insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWater connections\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eG ¾\" female thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-30 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePermissible operating pressure (p max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.485 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39173200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177983861\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Connection hose kit 3313.614 for LCU CW 3313.610\u003cbr\u003e**\u003cbr\u003eThe water connection kit allows simple cooling water connection of the\u003cbr\u003eLCU to fixed on-site piping.\u003cbr\u003eThe flexible hosing can compensate for dimensional deviations and the LCU CW can be decoupled from the on-site piping.\u003cbr\u003eTwo detachable half-shells allow the length of the hose to be shortened individually.\u003cbr\u003eDue to the hose length of 2.5 m, the medium connection can alternatively be made into the enclosure from below or from above.\u003cbr\u003eHose connection kit, packaging unit consisting of:\u003cbr\u003eTwo hydraulic hoses (NBR), resistant to water and\u003cbr\u003eantifreeze\u003cbr\u003eInsert made of steel wire spiral and fabric insert\u003cbr\u003eInside diameter: DN 19\u003cbr\u003eLength: 2500 mm\u003cbr\u003eOperating pressure 10 bar at 35°C\u003cbr\u003eTemperature range: -30°C to +70°C\u003cbr\u003eConnection side to the LCU:\u003cbr\u003e90° elbow, crimped, G 3\/4\" union nut, flat-sealing\u003cbr\u003eConnection side to on-site piping:\u003cbr\u003eShell cover mounted on hose, G 3\/4\" union nut\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; flat-sealing\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3313.614\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow many pieces does one packaging unit of the Rittal SK 3313.614 contain?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eOne packaging unit contains 2 pieces; the stated price applies per packaging unit.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the connection hose used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe connection hose is used to connect the LCP\/LCU to fixed piping.\u003c\/p\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377312534877,"sku":"3313614","price":445.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3313614-lcu-cw-wasseranschlusskit.jpg?v=1793628710"},{"product_id":"rittal-sk-3334440-chiller-blue-e-hybrid-it","title":"Rittal SK 3334.440 Chiller Blue e+ Hybrid IT, 450x1020x710 mm, operating weight 115 kg","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3334.440 (3334440)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 450 x 1020 x 710 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating weight:\u003c\/strong\u003e 115 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4069196005318\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3334.440\u003c\/strong\u003e (Chiller Blue e+ Hybrid IT; operating weight 115 kg) has external dimensions of 450 x 1020 x 710 mm (W x H x D). The Blue e+ Hybrid IT chiller combines refrigerant-circuit cooling with a directly integrated free cooler, thereby increasing energy efficiency when operating in the colder seasons. In addition, pumps with high-efficiency IE3 motors are used. Thanks to the aluminium enclosure with outdoor paint finish, the unit is suitable for outdoor installation without an additional canopy.\u003c\/p\u003e\u003cp\u003eThe Blue e+ Hybrid IT chiller combines refrigerant-circuit cooling with a directly integrated free cooler, thereby increasing energy efficiency when operating in the colder seasons. In addition, pumps with high-efficiency IE3 motors are used. Thanks to the aluminium enclosure with outdoor paint finish, the unit is suitable for outdoor installation without an additional canopy.\u003c\/p\u003e\u003cp\u003eThe enclosure is made of aluminium AlMg3 with a UV-resistant surface in RAL 7035 structure finish. Temperature control is handled by the e+ controller with a factory setting of +20 °C; the operating temperature range is -20 °C to 45 °C. The refrigerant used is R-513A.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor version:\u003c\/strong\u003e for outdoor installation without an additional canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminium AlMg3:\u003c\/strong\u003e enclosure material with UV-resistant surface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure-sealed water circuit:\u003c\/strong\u003e water connections ¾\" female thread\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoolant temperature range:\u003c\/strong\u003e 5 °C to 35 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category IP 24:\u003c\/strong\u003e electrics IP 54\u003c\/li\u003e\n\u003cli\u003eIntegrated free cooler increases energy efficiency\u003c\/li\u003e\n\u003cli\u003eConstant, precise cooling thanks to a temperature accuracy of ±0.5 K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for outdoor installation:\u003c\/strong\u003e optimum weather protection thanks to UV-resistant paint finish and protected touch display\u003c\/li\u003e\n\u003cli\u003eWide operating limits from -20 °C to 45 °C\u003c\/li\u003e\n\u003cli\u003eWorldwide use thanks to unique multi-voltage capability (without rewiring) and wide operating limits\u003c\/li\u003e\n\u003cli\u003eIntegrated heater for pre-heating the medium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCompletely ready-to-connect unit (pluggable terminal block)\u003c\/li\u003e\n\u003cli\u003eMultilingual documentation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3334440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOutdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium AlMg3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUV-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035 structure finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCompletely ready-to-connect unit (pluggable terminal block)\u003cbr\u003eMultilingual documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor remote monitoring and networking of Blue e+ generation cooling units and chillers, use the IoT Interface with article number 3124.300. Increase machine availability and process reliability through remote monitoring of unit data, states and system messages.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to EN 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 24, IP 54 (electrics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTotal cooling output to DIN EN 14511 Tw18 \/ Tu35\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCooling output Tw18 Tu35\/50 Hz: 5 kW\u003cbr\u003eCooling output Tw18 Tu35\/60 Hz: 4.8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e380 V - 415 V, 3~, 50 Hz, 440 V - 480 V, 3~, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 450 mm\u003cbr\u003eHeight: 1,020 mm\u003cbr\u003eDepth: 710 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ee+ controller (factory setting +20 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range of cooling medium\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRefrigerant\/cooling medium\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRefrigerant: R-513A\u003cbr\u003eQuantity: 1.2 kg\u003cbr\u003eGlobal Warming Potential (GWP): 631\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePump pressure\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 2.9 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVolume flow (cooling medium)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 14 l\/min\u003cbr\u003eAt 60 Hz: 14 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 2.55 kW\u003cbr\u003eAt 60 Hz: 2.73 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 4.04 A\u003cbr\u003eAt 60 Hz: 3.78 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWater circuit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003epressure-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWater connections\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e¾\" female thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of refrigerant circuits\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e104 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e114 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84186900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002516\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**The Blue e+ Hybrid IT chiller combines refrigerant-circuit cooling with a directly integrated free cooler, thereby increasing energy efficiency when operating in the colder seasons.\u003cbr\u003eIn addition, pumps with high-efficiency IE3 motors are used.\u003cbr\u003eThanks to the aluminium enclosure with outdoor paint finish, the unit is suitable for outdoor installation without an additional canopy.\u003cbr\u003eCentral and efficient cooling of liquid media with high\u003cbr\u003etemperature accuracy is achieved by innovative DC inverter technology, and worldwide use is made possible by the unique\u003cbr\u003emulti-voltage capability (without rewiring).\u003cbr\u003eMaximum safety is provided by an integrated overflow valve and\u003cbr\u003emonitoring sensors; intuitive operation is provided by\u003cbr\u003ea touch display and intelligent interfaces.\u003cbr\u003eA compact, modular design ensures a minimal\u003cbr\u003efootprint.\u003cbr\u003e**\u003cbr\u003eCooling capacity TW18 TU35, 50\/60 Hz: 5 \/ 4.8 kW\u003cbr\u003eRated power 50\/60 Hz: 2.55 \/ 2.73 kW\u003cbr\u003eCoolant flow rate 50\/60 Hz: 14 l\/min\u003cbr\u003ePump pressure (max.) at 50 Hz: 2.9 bar\u003cbr\u003eRated current 50\/60 Hz: 4.04 \/ 3.78 A\u003cbr\u003eRated operational voltage: 380-415 V, 3~, 50 Hz; 440-480 V, 3~, 60 Hz\u003cbr\u003eTemperature control: e+ controller (factory setting +20 °C)\u003cbr\u003eDimensions [WxHxD]: 450x1020x710 mm\u003cbr\u003eColour: aluminium with outdoor paint finish, RAL 7035\u003cbr\u003eExpansion vessel (material): steel\u003cbr\u003eExpansion vessel (capacity): 5 l\u003cbr\u003eRefrigerant type \/ quantity: R-513A \/ 1200 g\u003cbr\u003eNumber of refrigerant circuits: 1\u003cbr\u003eTemperature hysteresis: +\/- 0.5 K\u003cbr\u003eWater connections: 2x 3\/4\" female thread\u003cbr\u003eWater circuit: pressure-sealed\u003cbr\u003eOperating temperature: -20 °C to 45 °C\u003cbr\u003eLiquid medium temperature: 10 °C to 35 °C\u003cbr\u003eProtection category IP to IEC 60529: IP 24\u003cbr\u003eWeight: 105 kg\u003cbr\u003eNote: For remote monitoring and networking of cooling units and chillers of the Blue e+ generation, use the IoT interface with the\u003cbr\u003earticle number 3124.300. Increase machine availability and\u003cbr\u003eprocess reliability through remote monitoring of device data, statuses and system messages.\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3334.440\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3334.440?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 450 x 1020 x 710 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 3334.440 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 24 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3334.440?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eCompletely ready-to-connect unit (pluggable terminal block), multilingual documentation.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs the Blue e+ Hybrid IT chiller suitable for outdoor installation?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, thanks to the aluminium enclosure with outdoor paint finish, the unit is suitable for outdoor installation without an additional canopy.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 3334.440?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity - F-gas regulation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_11559\/3334440_Anleitung_ndash_R_513A_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions – R-513A\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8520\/3334440_Weiterf_uuml_hrende_Informationen_DE\" target=\"_blank\" rel=\"noopener\"\u003eFurther information\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377314074973,"sku":"3334440","price":6717.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3334440-1.jpg?v=1793644954"},{"product_id":"rittal-sk-5503020-lueftermodul-fuer-vx-it-ts-it","title":"Rittal SK 5503.020 fan module for VX IT, TS IT, 550x42x340 mm, RAL 7035","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 5503.020 (5503020)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 550 x 42 x 340 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT · TS IT · TX CableNet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966246\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 5503.020\u003c\/strong\u003e (fan module for VX IT, TS IT; RAL 7035) has external dimensions of 550 x 42 x 340 mm (W x H x D). For active ventilation. The unit can optionally be expanded with additional fans. Simple connection technology and energy-efficient speed control.\u003c\/p\u003e\u003cp\u003eThe fan module for VX IT and TS IT is used for active ventilation and is one of the Small Cooling Units in the IT cooling range. The unit is supplied wired ready for connection with two fans and can optionally be expanded with additional fans. In the version without roof plate, the fan module is inserted directly into the cut-out integrated in the roof plate.\u003c\/p\u003e\u003cp\u003eThe rated operational voltage is 100 V - 240 V at 1~ and 50 Hz\/60 Hz. The air flow rate at the operating point is 280 m³\/h, the sound pressure level 46 dB(A). The operating temperature range extends from 5 °C to 55 °C; the protection category is IP 20.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive ventilation:\u003c\/strong\u003e Speed-controlled fans, can optionally be expanded with further fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow rate at operating point:\u003c\/strong\u003e 280 m³\/h at 25 Pa back pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound pressure level at operating point:\u003c\/strong\u003e 46 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical protection:\u003c\/strong\u003e Upstream protection via miniature circuit breaker\/fuse 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded in the scope of supply:\u003c\/strong\u003e Fan unit with fans, fixing material and installation and quick-start instructions.\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003e2 fans\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 5503020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003e2 fans\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e280 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 V - 240 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.7 A\u003cbr\u003eAt 60 Hz: 0.69 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 550 mm\u003cbr\u003eHeight: 42 mm\u003cbr\u003eDepth: 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIn the VX IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003cbr\u003eIn the TS IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003cbr\u003eIn the TX CableNet with W x D (mm): 800 x 800 \/ 800 x 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow to 280 m³\/h at 25 Pa back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e46 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003cbr\u003eTS IT\u003cbr\u003eTX CableNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e42.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966246\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK fan module 100-240 V, 50-60 Hz\u003cbr\u003eArt. no. SK 5503.020\u003cbr\u003e**\u003cbr\u003eFan module for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 490x260 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. 2 axial fans with integrated speed controllers (expandable to max. 6 fans), fixing material and installation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e100-240 V, 1~, 50\/60 Hz\u003cbr\u003eRated power with 6 fans (max.): 34 W at 50\/60 Hz\u003cbr\u003eRated current with 6 fans (max.) at 50\/60 Hz: 0.34 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eFree-blowing air flow: 400 m³\/h\u003cbr\u003eAir flow at operating point:\u003cbr\u003e280 m³\/h at 25 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point: 46 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm: 550x42x340 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 7035 textured\u003cbr\u003eArt. no. SK 5503.020\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 5503.020\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 5503.020?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 550 x 42 x 340 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 5503.020 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 5503.020?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, 2 fans, wired ready for connection, incl. fixing material, installation and quick-start instructions.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan the fan module be expanded with further fans?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the unit can optionally be expanded with additional fans.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 5503.020?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003cli\u003eUK declaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9139\/5503020_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9190\/5503020_Weitere_Anleitungen_DE\" target=\"_blank\" rel=\"noopener\"\u003eFurther instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377730982237,"sku":"5503020","price":180.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-5503020-sk-lueftermodul.jpg?v=1793628821"},{"product_id":"rittal-sk-5503025-lueftermodul-fuer-vx-it-ts-it","title":"Rittal SK 5503.025 fan module for VX IT, TS IT, 550x42x340 mm, RAL 9005","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 5503.025 (5503025)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 550 x 42 x 340 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT · TS IT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e RAL 9005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966239\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 5503.025\u003c\/strong\u003e (fan module for VX IT, TS IT; RAL 9005) has external dimensions of 550 x 42 x 340 mm (W x H x D). For active ventilation. The unit can optionally be expanded with additional fans. Simple connection technology and energy-efficient speed control.\u003c\/p\u003e\u003cp\u003eThe fan module for VX IT and TS IT is used for active ventilation and is one of the Small Cooling Units in the IT cooling range. The unit is supplied wired ready for connection with two fans and can optionally be expanded with additional fans. In the version without roof plate, the fan module is inserted directly into the cut-out integrated in the roof plate.\u003c\/p\u003e\u003cp\u003eThe rated operational voltage is 100 V - 240 V at 1~ and 50 Hz\/60 Hz. The air flow rate at the operating point is 280 m³\/h, the sound pressure level 46 dB(A). The operating temperature range extends from 5 °C to 55 °C; the protection category is IP 20.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive ventilation:\u003c\/strong\u003e Speed-controlled fans, can optionally be expanded with further fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow rate at operating point:\u003c\/strong\u003e 280 m³\/h at 25 Pa back pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound pressure level at operating point:\u003c\/strong\u003e 46 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical protection:\u003c\/strong\u003e Upstream protection via miniature circuit breaker\/fuse 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded in the scope of supply:\u003c\/strong\u003e Fan unit with fans, fixing material and installation and quick-start instructions.\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003e2 fans\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 5503025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003e2 fans\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e280 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 V - 240 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.7 A\u003cbr\u003eAt 60 Hz: 0.69 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 550 mm\u003cbr\u003eHeight: 42 mm\u003cbr\u003eDepth: 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIn the VX IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003cbr\u003eIn the TS IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow to 280 m³\/h at 25 Pa back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e46 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003cbr\u003eTS IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e42.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK fan module 100-240 V, 50-60 Hz\u003cbr\u003eArt. no. SK 5503.025\u003cbr\u003e**\u003cbr\u003eFan module for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 490x260 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. 2 axial fans with integrated speed controllers (expandable to max. 6 fans), fixing material and installation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e100-240 V, 1~, 50\/60 Hz\u003cbr\u003eRated power with 6 fans (max.): 34 W at 50\/60 Hz\u003cbr\u003eRated current with 6 fans (max.) at 50\/60 Hz: 0.34 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eFree-blowing air flow: 400 m³\/h\u003cbr\u003eAir flow at operating point:\u003cbr\u003e280 m³\/h at 25 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point: 46 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm: 550x42x340 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 9005 matt, fine texture\u003cbr\u003eArt. no. SK 5503.025\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 5503.025\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 5503.025?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 550 x 42 x 340 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 5503.025 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 5503.025?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, 2 fans, wired ready for connection, incl. fixing material, installation and quick-start instructions.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan the fan module be expanded with further fans?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the unit can optionally be expanded with additional fans.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 5503.025?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003cli\u003eUK declaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9139\/5503025_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9190\/5503025_Weitere_Anleitungen_DE\" target=\"_blank\" rel=\"noopener\"\u003eFurther instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377731277149,"sku":"5503025","price":180.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-5503025-sk-lueftermodul.jpg?v=1793628821"},{"product_id":"rittal-sk-7980000-lueftererweiterungssatz","title":"Rittal SK 7980.000 fan extension kit, 119x119x38 mm, 230 V, 1~","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7980.000 (7980000)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 119 x 38 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 230 V, 1~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177137752\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7980.000\u003c\/strong\u003e (fan extension kit; 230 V, 1~) has external dimensions of 119 x 119 x 38 mm (W x H x D). For retrofitting various fan units or supplementing the fan plate.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit from the Small Cooling Units range is used for retrofitting various fan units or supplementing the fan plate. The scope of supply includes fan, connection cable (0.61 m) and fixing material.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofitting:\u003c\/strong\u003e Suitable for retrofitting various fan units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplement:\u003c\/strong\u003e Expansion of the fan plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply:\u003c\/strong\u003e Fan, connection cable (0.61 m) and fixing material.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eConnection cable (0.61 m)\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7980000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eConnection cable (0.61 m)\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate free-blowing (with non-woven filter)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 160 m³\/h\u003cbr\u003eAt 60 Hz: 180 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 15 W\u003cbr\u003eAt 60 Hz: 14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 119 mm\u003cbr\u003eDepth: 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-10 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 37 dB(A)\u003cbr\u003eAt 60 Hz: 37 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.671 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177137752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Fan extension kit for fan plate\u003cbr\u003e**\u003cbr\u003eRated operational voltage: 230 V;\u003cbr\u003eRated power: 19\/18 W at 50\/60 Hz;\u003cbr\u003eAir flow rate (free-blowing): 160-180 m3\/h, 50\/60\u003cbr\u003eHz; temperature range: -10°C to +55°C\u003cbr\u003eDimensions (W x H x D): 119 mm x 119 mm x 38 mm\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7980.000\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7980.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 119 x 38 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7980.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, connection cable (0.61 m), incl. fixing material.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_893\/7980000_Kennlinienfelder_DE\" target=\"_blank\" rel=\"noopener\"\u003eCharacteristic curves\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/7980000_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863004509,"sku":"7980000","price":35.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7980000-lueftererweiterungssatz-fuer-luefterblech.jpg?v=1793628821"},{"product_id":"rittal-sk-7980100-lueftererweiterungssatz","title":"Rittal SK 7980.100 fan expansion kit, 119x119x25 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7980.100 (7980100)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 119 x 25 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177187313\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7980.100\u003c\/strong\u003e (fan expansion kit) has external dimensions of 119 x 119 x 25 mm (W x H x D). For retrofitting various fan units or supplementing the fan plate.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit from the Small Cooling Units range is used for retrofitting various fan units or supplementing the fan plate. The scope of supply includes fan, connection cable (0.61 m) and fixing material.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofitting:\u003c\/strong\u003e Suitable for retrofitting various fan units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplement:\u003c\/strong\u003e Expansion of the fan plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply:\u003c\/strong\u003e Fan, connection cable (0.61 m) and fixing material.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eConnection cable (0.61 m)\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7980100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eConnection cable (0.61 m)\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate free-blowing (with non-woven filter)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 108 m³\/h\u003cbr\u003eAt 60 Hz: 120 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 14 W\u003cbr\u003eAt 60 Hz: 12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 119 mm\u003cbr\u003eDepth: 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 34 dB(A)\u003cbr\u003eAt 60 Hz: 34 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.486 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177187313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Fan expansion kit for EL\u003cbr\u003e**\u003cbr\u003eRated operational voltage: 230 V;\u003cbr\u003eRated power: 14\/12 W at 50\/60 Hz;\u003cbr\u003eAir flow rate (free-blowing): 108\/120 m3\/h, 50\/60\u003cbr\u003eHz; temperature range: -20°C to +70°C\u003cbr\u003eDimensions (W x H x D): 119 mm x 119 mm x 25 mm\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7980.100\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7980.100?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 119 x 25 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7980.100?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, connection cable (0.61 m), incl. fixing material.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_893\/7980100_Kennlinienfelder_DE\" target=\"_blank\" rel=\"noopener\"\u003eCharacteristic curves\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/7980100_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863037277,"sku":"7980100","price":44.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7980100-lueftererweiterungssatz-fuer-el.jpg?v=1793628821"},{"product_id":"rittal-sk-7980148-lueftererweiterungssatz","title":"Rittal SK 7980.148 fan expansion kit, 119x119x38 mm, 48 V (DC)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7980.148 (7980148)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 119 x 38 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 48 V (DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177325234\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7980.148\u003c\/strong\u003e (fan expansion kit; 48 V (DC)) has external dimensions of 119 x 119 x 38 mm (W x H x D). For retrofitting various fan units or supplementing the fan plate.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit from the Small Cooling Units range is used for retrofitting various fan units or supplementing the fan plate. The scope of supply includes fan, connection cable (0.61 m) and fixing material.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofitting:\u003c\/strong\u003e Suitable for retrofitting various fan units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplement:\u003c\/strong\u003e Expansion of the fan plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply:\u003c\/strong\u003e Fan, connection cable (0.61 m) and fixing material.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eConnection cable (0.61 m)\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7980148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eConnection cable (0.61 m)\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e184 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e48 V (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt DC: 7.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 119 mm\u003cbr\u003eDepth: 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt DC: 43 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.387 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177325234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Fan expansion kit WxHxD 119x119x38, 48 V\u003cbr\u003e**\u003cbr\u003eAir flow rate (free-blowing): 184 m3\/h\u003cbr\u003eHz; temperature range: -20°C to +70°C\u003cbr\u003eDimensions (W x H x D): 119 mm x 119 mm x 38 mm\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7980.148\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7980.148?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 119 x 38 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7980.148?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, connection cable (0.61 m), incl. fixing material.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_893\/7980148_Kennlinienfelder_DE\" target=\"_blank\" rel=\"noopener\"\u003eCharacteristic curves\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/7980148_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863070045,"sku":"7980148","price":50.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7980148-lueftererweiterungssatz.jpg?v=1793628821"},{"product_id":"rittal-sk-7990000-lueftererweiterungssatz-fuer-vx-it-ts-it","title":"Rittal SK 7990.000 fan expansion kit for VX IT, TS IT, 119x25x119 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7990.000 (7990000)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 25 x 119 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966345\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7990.000\u003c\/strong\u003e (fan expansion kit for VX IT, TS IT) has external dimensions of 119 x 25 x 119 mm (W x H x D). Fan expansion kit with integrated speed controller for retrofitting in the fan modules 5503.010, 5503.020 and 5503.025.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit for VX IT and TS IT with integrated speed controller is used for retrofitting in the fan modules. The version without roof plate is made of plastic in RAL 9005 and is designed for a rated operational voltage of 24 V (DC). The scope of supply includes fan, protective grille, fixing material and installation and quick-start instructions; a declaration of conformity is stated as proof.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating data:\u003c\/strong\u003e Rated power 7.7 W, rated operational voltage 24 V (DC), rated current max. 0.32 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow:\u003c\/strong\u003e 150 m³\/h at the operating point; the stated air flow applies at 25 Pa back pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20 to IEC 60 529.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e Sound pressure level 44 dB(A) at the operating point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e Operating temperature range 5 °C to 55 °C.\u003c\/li\u003e\n\u003cli\u003eReady-to-connect complete solution\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eProtective grille\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7990000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eProtective grille\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e150 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 V (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.32 A\u003cbr\u003eAt 60 Hz: 0.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 25 mm\u003cbr\u003eDepth: 119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow to 150 m³\/h at 25 Pa back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e44 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.308 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK fan expansion kit\u003cbr\u003eArt. no. SK 7990.000\u003cbr\u003e**\u003cbr\u003eFan expansion kit for fan modules with integrated speed controller for installing and expanding\u003cbr\u003efan modules, e.g. Rittal make: SK 5503.XXX incl. fixing material, fan grille and installation instructions\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage: 24 V DC\u003cbr\u003eRated power: 7.7 W\u003cbr\u003eRated current: 0.32 A\u003cbr\u003eAir flow at operating point:\u003cbr\u003e150 m³\/h @ 25 Pa,\u003cbr\u003eFree-blowing air flow: 192 m³\/h\u003cbr\u003eFree-blowing sound pressure level: 46 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD: 119x25x119 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: plastic\u003cbr\u003eColour: RAL 9005\u003cbr\u003eArt. no. SK 7990.000\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7990.000\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7990.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 25 x 119 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 7990.000 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7990.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, protective grille, incl. fixing material, installation and quick-start instructions.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_15459\/7990000_Anleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863102813,"sku":"7990000","price":33.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7990000-sk-lueftererweiterungssatz.jpg?v=1793628822"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/collections\/rittal-sk-3301320-schaumgummi-dick.jpg?v=1793652234","url":"https:\/\/www.iam24.de\/en\/collections\/rittal-klimatisierung-it-cooling.oembed","provider":"IAM24","version":"1.0","type":"link"}