{"title":"Rittal Power Distribution Unit PDU","description":"\u003cp\u003eRittal Power Distribution Unit PDU at IAM24: 112 genuine Rittal articles. The article number (e.g. SV 3569.005 or 3569005) and the data sheet are shown on every product page.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/en\/collections\/rittal#produktgruppen\"\u003eAll Rittal product groups\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/rittal\"\u003eAll Rittal products\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"rittal-dk-7979102-pdu-basic","title":"Rittal DK 7979.102 PDU basic, 44x144 mm (HxD), number and type of sockets 8 x C13","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.102 (7979102)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 800 mm · Enclosure type: VX IT 19\" support rails: ≥ 800 mm · Enclosure type: TX CableNet: ≥ 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 8 x C13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947351\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.102\u003c\/strong\u003e (PDU basic; number and type of sockets 8 x C13) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eWithout connecting cable, to be supplied by the customer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eVersion 19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003cbr\u003eWithout connecting cable, to be supplied by the customer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 44 mm\u003cbr\u003eDepth: 144 mm\u003cbr\u003eLength: 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e8 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIEC C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 800 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.102\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Robust aluminium housing with permanently mounted output sockets, depending on\u003cbr\u003etype IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 8\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 8\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug: EN 60320 \/ IEC C20\u003cbr\u003ePDU housing width: 450 mm\u003cbr\u003ePDU housing depth: 144 mm\u003cbr\u003ePDU housing height: 44 mm (1HE)\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.102\u003cbr\u003ePDU Basic 16A\/1P IEC 20 8xC13\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.102\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.102?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material, without connecting cable, must be supplied by the customer.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.102?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979102_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857335645,"sku":"7979102","price":93.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979102-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979103-pdu-basic","title":"Rittal DK 7979.103 PDU basic, 44x144 mm (HxD), number and type of sockets 8 x Schuko, type F, CEE 7\/3","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.103 (7979103)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 800 mm · Enclosure type: VX IT 19\" support rails: ≥ 800 mm · Enclosure type: TX CableNet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 8 x Schuko, type F, CEE 7\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947368\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.103\u003c\/strong\u003e (PDU basic; number and type of sockets 8 x Schuko, type F, CEE 7\/3) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eVersion 19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 44 mm\u003cbr\u003eDepth: 144 mm\u003cbr\u003eLength: 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e8 x Schuko, type F, CEE 7\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 800 mm\u003cbr\u003eEnclosure type: TX CableNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947368\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.103\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Robust aluminium housing with permanently mounted output sockets, depending on\u003cbr\u003etype IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 8\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): 8\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 450 mm\u003cbr\u003ePDU housing depth: 144 mm\u003cbr\u003ePDU housing height: 44 mm (1HE)\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.103\u003cbr\u003ePDU Basic 16A\/1P CEE 8xearthing-pin\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.103\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.103?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.103?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979103_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857368413,"sku":"7979103","price":80.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979103-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979104-pdu-basic","title":"Rittal DK 7979.104 PDU basic, 44x144 mm (HxD), number and type of sockets 4 x C13 \/ 2 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.104 (7979104)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 800 mm · Enclosure type: VX IT 19\" support rails: ≥ 800 mm · Enclosure type: TX CableNet: ≥ 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 4 x C13 \/ 2 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947375\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.104\u003c\/strong\u003e (PDU basic; number and type of sockets 4 x C13 \/ 2 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eVersion 19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 44 mm\u003cbr\u003eDepth: 144 mm\u003cbr\u003eLength: 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 x C13 \/ 2 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 800 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.104\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Robust aluminium housing with permanently mounted output sockets, depending on\u003cbr\u003etype IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 4\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): - \/ 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): - \/ 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 450 mm\u003cbr\u003ePDU housing depth: 144 mm\u003cbr\u003ePDU housing height: 44 mm (1HE)\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.104\u003cbr\u003ePDU Basic 32A\/1P CEE 4xC13 \/ 2xC19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.104\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.104?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.104?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979104_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857433949,"sku":"7979104","price":152.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979104-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979110-pdu-basic","title":"Rittal DK 7979.110 PDU basic, 44x70 mm (WxD), number and type of sockets 12 x C13 \/ 1 x C19, rated current (max.) 16 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.110 (7979110)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · Enclosure type: VX IT 19\" support rails: ≥ 1,200 mm · Enclosure type: TX CableNet: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C13 \/ 1 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947382\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.110\u003c\/strong\u003e (PDU basic; number and type of sockets 12 x C13 \/ 1 x C19, rated current (max.) 16 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C13 \/ 1 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.110\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 1\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.110\u003cbr\u003ePDU Basic 16A\/1P CEE 12xC13 \/ 1xC19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.110\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.110?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.110?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979110_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857499485,"sku":"7979110","price":125.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979110-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979111-pdu-basic","title":"Rittal DK 7979.111 PDU basic, 44x70 mm (WxD), number and type of sockets 10 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.111 (7979111)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 10 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947405\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.111\u003c\/strong\u003e (PDU basic; number and type of sockets 10 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInput cable connection (type\/length)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.111\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 10\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): 10\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.111\u003cbr\u003ePDU Basic 16A\/1P CEE 10x earthing-pin\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.111\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.111?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.111?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979111_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857597789,"sku":"7979111","price":87.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979111-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979112-pdu-basic","title":"Rittal DK 7979.112 PDU basic, 44x70 mm (WxD), number and type of sockets 16 x C13 \/ 2 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.112 (7979112)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · Enclosure type: VX IT 19\" support rails: ≥ 1,200 mm · Enclosure type: TX CableNet: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 16 x C13 \/ 2 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947412\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.112\u003c\/strong\u003e (PDU basic; number and type of sockets 16 x C13 \/ 2 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 845 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 x C13 \/ 2 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.112\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 16\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): - \/ 8\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): - \/ 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 845 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eWarranty: 24 months\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.112\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.112\u003cbr\u003ePDU Basic 32A\/1P CEE 16x C13 \/ 2x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.112\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.112?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.112?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979112_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857630557,"sku":"7979112","price":197.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979112-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979113-pdu-basic","title":"Rittal DK 7979.113 PDU basic, 44x70 mm (WxD), number and type of sockets 12 x C13 \/ 4 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.113 (7979113)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · Enclosure type: VX IT 19\" support rails: ≥ 1,200 mm · Enclosure type: TX CableNet: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C13 \/ 4 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947429\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.113\u003c\/strong\u003e (PDU basic; number and type of sockets 12 x C13 \/ 4 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 845 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C13 \/ 4 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947429\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.113\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): - \/ 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 4\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): - \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 845 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.113\u003cbr\u003ePDU Basic 32A\/1P CEE 12x C13 \/ 4x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.113\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.113?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.113?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979113_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857663325,"sku":"7979113","price":197.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979113-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979114-pdu-basic","title":"Rittal DK 7979.114 PDU basic, 44x70 mm (WxD), number and type of sockets 16 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.114 (7979114)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 16 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947436\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.114\u003c\/strong\u003e (PDU basic; number and type of sockets 16 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947436\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.114\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 16\u003cbr\u003eNumber of Type CEE 7\/3 slots (per phase\/fuse): - \/ 8\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.114\u003cbr\u003ePDU Basic 32A\/1P CEE 16x earthing-pin\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.114\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.114?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.114?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979114_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857696093,"sku":"7979114","price":156.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979114-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979115-pdu-basic","title":"Rittal DK 7979.115 PDU basic, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 4 x C19, rated current (max.) 16 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.115 (7979115)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · Enclosure type: VX IT 19\" support rails: ≥ 1,800 mm · Enclosure type: TX CableNet: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 4 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947443\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.115\u003c\/strong\u003e (PDU basic; number and type of sockets 24 x C13 \/ 4 x C19, rated current (max.) 16 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 4 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.115\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 4\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 4\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.115\u003cbr\u003ePDU Basic 16A\/1P CEE 24xC13 \/ 4xC19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.115\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.115?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.115?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979115_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857761629,"sku":"7979115","price":183.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979115-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979116-pdu-basic","title":"Rittal DK 7979.116 PDU basic, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 4 x C19, rated current (max.) 32 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.116 (7979116)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · Enclosure type: VX IT 19\" support rails: ≥ 1,800 mm · Enclosure type: TX CableNet: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 4 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947450\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.116\u003c\/strong\u003e (PDU basic; number and type of sockets 24 x C13 \/ 4 x C19, rated current (max.) 32 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 4 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInput cable connection (type\/length)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.116\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): - \/ 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 4\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): - \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU enclosure height: 1295 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.116\u003cbr\u003ePDU Basic 32A\/1P CEE 24xC13 \/ 4xC19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.116\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.116?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.116?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979116_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857827165,"sku":"7979116","price":244.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979116-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979117-pdu-basic","title":"Rittal DK 7979.117 PDU basic, 44x70 mm (WxD), number and type of sockets 12 x C13 \/ 1 x C19, rated current (max.) 16 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.117 (7979117)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · Enclosure type: VX IT 19\" support rails: ≥ 1,200 mm · Enclosure type: TX CableNet: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C13 \/ 1 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177973435\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.117\u003c\/strong\u003e (PDU basic; number and type of sockets 12 x C13 \/ 1 x C19, rated current (max.) 16 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C13 \/ 1 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIEC C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177973435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Rittal PDU basic art. no.: DK 7979.117\u003cbr\u003ePDU Basic 16A\/1P IEC C20 12xC13 \/ 1xC19**\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eA connection cable with IEC C20 or CEE plug makes the PDU ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 1\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug: EN 60320 \/ IEC C20\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.117\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.117\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.117?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.117?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979117_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857859933,"sku":"7979117","price":114.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979117-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979118-pdu-basic","title":"Rittal DK 7979.118 PDU basic, 44x70 mm (WxD), number and type of sockets 18 x C13 \/ 2 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.118 (7979118)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · Enclosure type: VX IT 19\" support rails: ≥ 1,200 mm · Enclosure type: TX CableNet: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x C13 \/ 2 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177973442\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.118\u003c\/strong\u003e (PDU basic; number and type of sockets 18 x C13 \/ 2 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 845 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 2 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIEC C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003cbr\u003eEnclosure type: TX CableNet: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177973442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Rittal PDU basic art. no.: DK 7979.118\u003cbr\u003ePDU Basic 16A\/1P IEC C20 18xC13 \/ 2xC19\u003cbr\u003e**\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eA connection cable with IEC C20 or CEE plug makes the PDU ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug: EN 60320 \/ IEC C20\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 845 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.118\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.118\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.118?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.118?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9143\/7979118_Technik_im_Detail_2_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnology in detail 2\u003c\/a\u003e (DE)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377857925469,"sku":"7979118","price":136.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979118-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979130-pdu-basic","title":"Rittal DK 7979.130 PDU basic, 44x70 mm (WxD), number and type of sockets 9 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.130 (7979130)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 9 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947467\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.130\u003c\/strong\u003e (PDU basic; number and type of sockets 9 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e9 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.86 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.130\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 9\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 3\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.130\u003cbr\u003ePDU Basic 16A\/3P CEE 9x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.130\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.130?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.130?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979130_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858023773,"sku":"7979130","price":134.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979130-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979131-pdu-basic","title":"Rittal DK 7979.131 PDU basic, 44x70 mm (WxD), number and type of sockets 12 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.131 (7979131)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947474\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.131\u003c\/strong\u003e (PDU basic; number and type of sockets 12 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 3\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.131\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 12\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.131\u003cbr\u003ePDU Basic 32A\/3P CEE 12x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.131\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.131?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.131?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979131_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858122077,"sku":"7979131","price":284.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979131-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979132-pdu-basic","title":"Rittal DK 7979.132 PDU basic, 44x70 mm (WxD), number and type of sockets 6 x C13 \/ 6 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.132 (7979132)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 6 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947481\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.132\u003c\/strong\u003e (PDU basic; number and type of sockets 6 x C13 \/ 6 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.501 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.132\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.132\u003cbr\u003ePDU Basic 16A\/3P CEE 6x C13 \/ 6x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.132\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.132?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.132?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979132_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858220381,"sku":"7979132","price":138.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979132-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979133-pdu-basic","title":"Rittal DK 7979.133 PDU basic, 44x70 mm (WxD), number and type of sockets 18 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.133 (7979133)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947498\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.133\u003c\/strong\u003e (PDU basic; number and type of sockets 18 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947498\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.133\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 18\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): 6\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.133\u003cbr\u003ePDU Basic 16A\/3P CEE 18x earthing-pin\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.133\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.133?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.133?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979133_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858253149,"sku":"7979133","price":111.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979133-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979134-pdu-basic","title":"Rittal DK 7979.134 PDU basic, 44x70 mm (WxD), number and type of sockets 24 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.134 (7979134)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947504\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.134\u003c\/strong\u003e (PDU basic; number and type of sockets 24 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.134\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 24\u003cbr\u003eNumber of Type CEE 7\/3 slots (per phase\/fuse): 8 \/ 4\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessories): DK DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.134\u003cbr\u003ePDU Basic 32A\/3P CEE 24x earthing-pin\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.134\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.134?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.134?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979134_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858285917,"sku":"7979134","price":257.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979134-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979135-pdu-basic","title":"Rittal DK 7979.135 PDU basic, 44x70 mm (WxD), number and type of sockets 18 x C13 \/ 3 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.135 (7979135)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x C13 \/ 3 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.135\u003c\/strong\u003e (PDU basic; number and type of sockets 18 x C13 \/ 3 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 845 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 3 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.135\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 3\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 845 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.135\u003cbr\u003ePDU Basic 16A\/3P CEE 18xC13 \/ 3xC19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.135\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.135?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.135?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979135_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858384221,"sku":"7979135","price":175.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979135-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979136-pdu-basic","title":"Rittal DK 7979.136 PDU basic, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 6 x C19, rated current (max.) 16 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.136 (7979136)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947528\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.136\u003c\/strong\u003e (PDU basic; number and type of sockets 24 x C13 \/ 6 x C19, rated current (max.) 16 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947528\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.136\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 8\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.136\u003cbr\u003ePDU Basic 16A\/3P CEE 24xC13 \/ 6xC19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.136\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.136?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.136?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979136_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858449757,"sku":"7979136","price":202.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979136-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979137-pdu-basic","title":"Rittal DK 7979.137 PDU basic, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 6 x C19, rated current (max.) 32 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.137 (7979137)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947535\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.137\u003c\/strong\u003e (PDU basic; number and type of sockets 24 x C13 \/ 6 x C19, rated current (max.) 32 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.137\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 8 \/ 4\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 2 \/ 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU enclosure height: 1495 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.137\u003cbr\u003ePDU Basic 32A\/3P CEE 24xC13 \/ 6xC19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.137\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.137?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.137?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979137_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858515293,"sku":"7979137","price":353.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979137-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979138-pdu-basic","title":"Rittal DK 7979.138 PDU basic, 44x70 mm (WxD), number and type of sockets 18 x C13 \/ 12 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.138 (7979138)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x C13 \/ 12 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947542\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.138\u003c\/strong\u003e (PDU basic; number and type of sockets 18 x C13 \/ 12 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 12 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947542\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.138\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 4\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1295 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.138\u003cbr\u003ePDU Basic 16A\/3P CEE 18x C13 \/ 12x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.138\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.138?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.138?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979138_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858548061,"sku":"7979138","price":229.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979138-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979139-pdu-basic","title":"Rittal DK 7979.139 PDU basic, 44x70 mm (WxD), number and type of sockets 12 x C13 \/ 12 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.139 (7979139)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C13 \/ 12 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947559\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.139\u003c\/strong\u003e (PDU basic; number and type of sockets 12 x C13 \/ 12 x C19) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979139\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C13 \/ 12 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947559\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.139\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 12\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1495 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.139\u003cbr\u003ePDU Basic 32A\/3P CEE 12x C13 \/ 12x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.139\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.139?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.139?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979139_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858580829,"sku":"7979139","price":353.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979139-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979140-pdu-basic","title":"Rittal DK 7979.140 PDU basic, 44x70 mm (WxD), number and type of sockets 36 x C13 \/ 6 x C19, rated current (max.) 16 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.140 (7979140)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 36 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947566\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.140\u003c\/strong\u003e (PDU basic; number and type of sockets 36 x C13 \/ 6 x C19, rated current (max.) 16 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e36 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.140\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 36\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 6\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1495 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.140\u003cbr\u003ePDU Basic 16A\/3P CEE 36x C13 \/ 6x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.140\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.140?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.140?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979140_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858646365,"sku":"7979140","price":257.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979140-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979141-pdu-basic","title":"Rittal DK 7979.141 PDU basic, 44x70 mm (WxD), number and type of sockets 36 x C13 \/ 6 x C19, rated current (max.) 32 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.141 (7979141)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 2,000 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 36 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947573\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.141\u003c\/strong\u003e (PDU basic; number and type of sockets 36 x C13 \/ 6 x C19, rated current (max.) 32 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,895 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e36 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 2,000 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947573\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.141\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 36\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 12 \/ 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 2 \/ 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1895 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.141\u003cbr\u003ePDU Basic 32A\/3P CEE 36x C13 \/ 6x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.141\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.141?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.141?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979141_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858679133,"sku":"7979141","price":401.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979141-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979142-pdu-basic","title":"Rittal DK 7979.142 PDU basic, 44x70 mm (WxD), number and type of sockets 42 x C13","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.142 (7979142)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 42 x C13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947580\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.142\u003c\/strong\u003e (PDU basic; number and type of sockets 42 x C13) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e42 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.142\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 42\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 14\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1495 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.142\u003cbr\u003ePDU Basic 16A\/3P CEE 42xC13\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.142\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.142?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.142?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979142_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858711901,"sku":"7979142","price":247.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979142-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979143-pdu-basic","title":"Rittal DK 7979.143 PDU basic, 44x70 mm (WxD), number and type of sockets 48 x C13","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.143 (7979143)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 2,000 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 48 x C13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947597\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.143\u003c\/strong\u003e (PDU basic; number and type of sockets 48 x C13) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,895 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e48 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 2,000 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947597\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.143\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 48\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 16 \/ 8\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1895 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK F63997955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.143\u003cbr\u003ePDU Basic 32A\/3P CEE 48x C13\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.143\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.143?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.143?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979143_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858744669,"sku":"7979143","price":401.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979143-pdu-basic.jpg?v=1793628152"},{"product_id":"rittal-dk-7979175-pdu-basic","title":"Rittal DK 7979.175 PDU basic, 44x70 mm (WxD), number and type of sockets 18 x C13 \/ 3 x C19, 6 x Schuko","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.175 (7979175)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x C13 \/ 3 x C19, 6 x Schuko\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177979833\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.175\u003c\/strong\u003e (PDU basic; number and type of sockets 18 x C13 \/ 3 x C19, 6 x Schuko) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 3 x C19, 6 x Schuko\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 3\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177979833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Rittal PDU basic art. no.: DK 7979.175\u003cbr\u003ePDU Basic 16A\/3P CEE 18xC13 \/ 3xC19 \/ 6xSchuko\u003cbr\u003e**\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 3\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 6\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.175\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.175\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.175?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.175?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAUZ\/NZ Declaration of conformity\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979175_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858810205,"sku":"7979175","price":194.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979175-pdu-basic.jpg?v=1793628153"},{"product_id":"rittal-dk-7979202-pdu-metered","title":"Rittal DK 7979.202 PDU metered, 44x144 mm (HxD), number and type of sockets 6 x C13","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.202 (7979202)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 800 mm · enclosure type: VX IT 19\" profile rails: ≥ 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 6 x C13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947603\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.202\u003c\/strong\u003e (PDU metered; number and type of sockets 6 x C13) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eWithout connecting cable, to be supplied by the customer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eVersion 19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003cbr\u003eWithout connecting cable, to be supplied by the customer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 44 mm\u003cbr\u003eDepth: 144 mm\u003cbr\u003eLength: 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIEC C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant monitoring via 2nd network\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.202\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Robust aluminium housing with permanently mounted output sockets, depending on\u003cbr\u003etype IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003ecan be forwarded to DCIM software via SNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector: IEC 60320 \/ IEC 20\u003cbr\u003ePDU housing width: 450 mm\u003cbr\u003ePDU housing depth: 144 mm\u003cbr\u003ePDU housing height: 44 mm (1HE)\u003cbr\u003ePDU material: aluminium, anodised in RAL 9005, other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase): -\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.202\u003cbr\u003ePDU metered 16A\/1P IEC C20 6xC13\u003cbr\u003ePDU metered 16A\/1P IEC C20 6xC13\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.202\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.202?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fastening material, without connection cable, to be provided by the customer.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.202?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979202_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979202_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979202_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858908509,"sku":"7979202","price":563.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979202-pdu-metered.jpg?v=1793628153"},{"product_id":"rittal-dk-7979203-pdu-metered","title":"Rittal DK 7979.203 PDU metered, 44x144 mm (HxD), number and type of sockets 4 x Schuko, Type F, CEE 7\/3","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.203 (7979203)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 800 mm · enclosure type: VX IT 19\" profile rails: ≥ 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 4 x Schuko, type F, CEE 7\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947610\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.203\u003c\/strong\u003e (PDU metered; number and type of sockets 4 x Schuko, Type F, CEE 7\/3) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ± 0.5 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eVersion 19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 44 mm\u003cbr\u003eDepth: 144 mm\u003cbr\u003eLength: 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 x Schuko, type F, CEE 7\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.203\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Robust aluminium housing with permanently mounted output sockets, depending on\u003cbr\u003etype IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 4\u003cbr\u003eNumber of Type CEE 7\/3 slots (per phase\/fuse): 4 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 450 mm\u003cbr\u003ePDU housing depth: 144 mm\u003cbr\u003ePDU housing height: 44 mm (1 U)\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eWarranty: 24 months\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.203\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.203\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.203?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.203?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979203_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979203_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979203_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858941277,"sku":"7979203","price":545.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979203-pdu-metered.jpg?v=1793628152"},{"product_id":"rittal-dk-7979204-pdu-metered","title":"Rittal DK 7979.204 PDU metered, 44x144 mm (HxD), number and type of sockets 4 x C13 \/ 2 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.204 (7979204)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 800 mm · enclosure type: VX IT 19\" profile rails: ≥ 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 4 x C13 \/ 2 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947627\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.204\u003c\/strong\u003e (PDU metered; number and type of sockets 4 x C13 \/ 2 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eVersion 19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 44 mm\u003cbr\u003eDepth: 144 mm\u003cbr\u003eLength: 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 x C13 \/ 2 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.204\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Robust aluminium housing with permanently mounted output sockets, depending on\u003cbr\u003etype IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 4\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 2\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 2 \/ 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 450 mm\u003cbr\u003ePDU housing depth: 144 mm\u003cbr\u003ePDU housing height: 44 mm (1 U)\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.204\u003cbr\u003ePDU metered 32A\/1P CEE 4x C13 \/ 2x C19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.204\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.204\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.204?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.204?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979204_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979204_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979204_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858974045,"sku":"7979204","price":573.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979204-pdu-metered.jpg?v=1793628152"},{"product_id":"rittal-dk-7979210-pdu-metered","title":"Rittal DK 7979.210 PDU metered, 44x70 mm (WxD), number and type of sockets 12 x C13 \/ 1 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.210 (7979210)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C13 \/ 1 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947634\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.210\u003c\/strong\u003e (PDU metered; number and type of sockets 12 x C13 \/ 1 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 845 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C13 \/ 1 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.210\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 1\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of Type CEE 7\/3 slots (per phase\/fuse):\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 845 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.210\u003cbr\u003ePDU metered 16A\/1P CEE 12xC13 \/ 1xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.210\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.210\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.210?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.210?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979210_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979210_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979210_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859039581,"sku":"7979210","price":528.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979210-pdu-metered.jpg?v=1793628153"},{"product_id":"rittal-dk-7979211-pdu-metered","title":"Rittal DK 7979.211 PDU metered, 44x70 mm (WxD), number and type of sockets 10 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.211 (7979211)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 10 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947641\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.211\u003c\/strong\u003e (PDU metered; number and type of sockets 10 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947641\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.211\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (total):\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 10\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): 10\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.210\u003cbr\u003ePDU metered 16A\/1P CEE 10x earthing-pin\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.211\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.211\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.211?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.211?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979211_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979211_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979211_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859072349,"sku":"7979211","price":533.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979211-pdu-metered.jpg?v=1793628152"},{"product_id":"rittal-dk-7979212-pdu-metered","title":"Rittal DK 7979.212 PDU metered, 44x70 mm (WxD), number and type of sockets 16 x C13 \/ 2 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.212 (7979212)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 16 x C13 \/ 2 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947658\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.212\u003c\/strong\u003e (PDU metered; number and type of sockets 16 x C13 \/ 2 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 x C13 \/ 2 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.179 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.212\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 16\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 16 \/ 8\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 2\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 2 \/ 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.212\u003cbr\u003ePDU metered 32A\/1P CEE 16x C13 \/ 2x C19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.212\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.212\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.212?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.212?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979212_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979212_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979212_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859105117,"sku":"7979212","price":631.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979212-pdu-metered.jpg?v=1793628152"},{"product_id":"rittal-dk-7979213-pdu-metered","title":"Rittal DK 7979.213 PDU metered, 44x70 mm (WxD), number and type of sockets 12 x C13 \/ 4 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.213 (7979213)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C13 \/ 4 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947665\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.213\u003c\/strong\u003e (PDU metered; number and type of sockets 12 x C13 \/ 4 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C13 \/ 4 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.213\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 12 \/ 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 4\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.213\u003cbr\u003ePDU metered 32A\/1P CEE 12x C13 \/ 4x C19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.213\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.213\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.213?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.213?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979213_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979213_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979213_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859137885,"sku":"7979213","price":631.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979213-pdu-metered.jpg?v=1793628153"},{"product_id":"rittal-dk-7979214-pdu-metered","title":"Rittal DK 7979.214 PDU metered, 44x70 mm (WxD), number and type of sockets 16 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.214 (7979214)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 16 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947672\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.214\u003c\/strong\u003e (PDU metered; number and type of sockets 16 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.214\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 16\u003cbr\u003eNumber of Type CEE 7\/3 slots (per phase\/fuse): 16 \/ 8\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1295 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.214\u003cbr\u003ePDU metered 32A\/1P CEE 16x earthing-pin\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.214\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.214\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.214?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.214?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979214_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979214_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979214_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859203421,"sku":"7979214","price":607.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979214-pdu-metered.jpg?v=1793628153"},{"product_id":"rittal-dk-7979215-pdu-metered","title":"Rittal DK 7979.215 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 4 x C19, 230 V (AC)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.215 (7979215)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 4 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 230 V (AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947689\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.215\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x C13 \/ 4 x C19, 230 V (AC)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 4 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947689\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.215\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 4\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 4\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1295 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.215\u003cbr\u003ePDU metered 16A\/1P CEE 24xC13 \/ 4xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.215\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.215\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.215?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.215?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979215_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979215_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979215_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859236189,"sku":"7979215","price":563.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979215-pdu-metered.jpg?v=1793628152"},{"product_id":"rittal-dk-7979216-pdu-metered","title":"Rittal DK 7979.216 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 4 x C19, 230 V (AC)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.216 (7979216)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 4 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 230 V (AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947696\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.216\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x C13 \/ 4 x C19, 230 V (AC)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eOther housing colours possible\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 4 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947696\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.216\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 24 \/ 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 4\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1495 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.216\u003cbr\u003ePDU metered 32A\/1P CEE 24xC13 \/ 4xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.216\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.216\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.216?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.216?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979216_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979216_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979216_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859268957,"sku":"7979216","price":573.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979216-pdu-metered.jpg?v=1793628153"},{"product_id":"rittal-dk-7979218-pdu-metered","title":"Rittal DK 7979.218 PDU metered, 44x70 mm (WxD), number and type of sockets 18 x C13 \/ 2 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.218 (7979218)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x C13 \/ 2 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177973466\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.218\u003c\/strong\u003e (PDU metered; number and type of sockets 18 x C13 \/ 2 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 2 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIEC C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFully redundant monitoring via 2nd network\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177973466\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Rittal PDU Metered art. no.: DK 7979.218\u003cbr\u003ePDU metered 16A\/1P IEC C20 12xC13 \/ 1xC19**\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eA connection cable with IEC C20 or CEE plug makes the PDU ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature\/ humidity\/ smoke\/ leakage\/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eOptionally, all PDU versions, except the PDU Basic\u003cbr\u003eseries, are available with an all-current-sensitive\u003cbr\u003eresidual current measurement (RCM Type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 1\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug: EN 60320 \/ IEC C20\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 845 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.218\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.218\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.218?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.218?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979218_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979218_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979218_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859301725,"sku":"7979218","price":543.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979218-pdu-metered.jpg?v=1793628153"},{"product_id":"rittal-dk-7979230-pdu-metered","title":"Rittal DK 7979.230 PDU metered, 44x70 mm (WxD), number and type of sockets 9 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.230 (7979230)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 9 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947702\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.230\u003c\/strong\u003e (PDU metered; number and type of sockets 9 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 845 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e9 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.230\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 9\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 3\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 0\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): 0\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 845 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.230\u003cbr\u003ePDU metered 16A\/3P CEE 9x C19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.230\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.230\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979230_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979230_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979230_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859367261,"sku":"7979230","price":673.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979230-pdu-metered.jpg?v=1793628153"},{"product_id":"rittal-dk-7979233-pdu-metered","title":"Rittal DK 7979.233 PDU metered, 44x70 mm (WxD), number and type of sockets 18 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.233 (7979233)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947733\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.233\u003c\/strong\u003e (PDU metered; number and type of sockets 18 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947733\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.233\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 18\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): 6\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1295 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.233\u003cbr\u003ePDU metered 16A\/3P CEE 18x earthing-pin\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.233\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.233\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.233?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.233?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979233_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979233_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979233_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859400029,"sku":"7979233","price":625.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979233-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979234-pdu-metered","title":"Rittal DK 7979.234 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x Schuko (Type F, CEE 7\/3)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.234 (7979234)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 2,000 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x Schuko (Type F, CEE 7\/3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947740\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.234\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x Schuko (Type F, CEE 7\/3)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,895 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x Schuko (Type F, CEE 7\/3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 2,000 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.234\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 24\u003cbr\u003eNumber of Type CEE 7\/3 slots (per phase\/fuse): 8 \/ 4\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1895 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.234\u003cbr\u003ePDU metered 32A\/3P CEE 24x earthing-pin\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.234\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.234\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.234?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.234?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979234_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979234_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979234_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859432797,"sku":"7979234","price":741.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979234-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979235-pdu-metered","title":"Rittal DK 7979.235 PDU metered, 44x70 mm (WxD), number and type of sockets 18 x C13 \/ 3 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.235 (7979235)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x C13 \/ 3 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947757\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.235\u003c\/strong\u003e (PDU metered; number and type of sockets 18 x C13 \/ 3 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 3 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947757\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.235\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 3\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 1\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eVoltage accuracy 2%\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.235\u003cbr\u003ePDU metered 16A\/3P CEE 18xC13 \/ 3xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.235\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.235\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.235?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.235?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979235_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979235_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979235_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377859989853,"sku":"7979235","price":637.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979235-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979236-pdu-metered","title":"Rittal DK 7979.236 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 6 x C19, 400 V (AC)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.236 (7979236)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 400 V (AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947764\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.236\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x C13 \/ 6 x C19, 400 V (AC)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ± 0.5 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.236\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1495 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.236\u003cbr\u003ePDU metered 16A\/3P CEE 24xC13 \/ 6xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.236\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.236\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.236?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.236?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979236_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979236_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979236_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860055389,"sku":"7979236","price":637.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979236-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979237-pdu-metered","title":"Rittal DK 7979.237 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 6 x C19, 400 V (AC)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.237 (7979237)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 2,000 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 400 V (AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947771\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.237\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x C13 \/ 6 x C19, 400 V (AC)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ± 0.5 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,740 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 2,000 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7955.237\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse 1 per phase): 8 \/ 8\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse 2 per phase): 2 \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1740 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.237\u003cbr\u003ePDU metered 32A\/3P CEE 24xC13 \/ 6xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7955.237\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.237\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.237?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.237?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979237_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979237_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979237_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860088157,"sku":"7979237","price":759.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979237-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979238-pdu-metered","title":"Rittal DK 7979.238 PDU metered, 44x70 mm (WxD), number and type of sockets 18 x C13 \/ 12 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.238 (7979238)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 18 x C13 \/ 12 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947788\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.238\u003c\/strong\u003e (PDU metered; number and type of sockets 18 x C13 \/ 12 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ± 0.5 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 12 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.238\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 4\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.238\u003cbr\u003ePDU metered 16A\/3P CEE 18x C13 \/ 12x C19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.238\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.238\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.238?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.238?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979238_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979238_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979238_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860120925,"sku":"7979238","price":690.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979238-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979239-pdu-metered","title":"Rittal DK 7979.239 PDU metered, 44x70 mm (WxD), number and type of sockets 12 x C13 \/ 12 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.239 (7979239)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 12 x C13 \/ 12 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947795\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.239\u003c\/strong\u003e (PDU metered; number and type of sockets 12 x C13 \/ 12 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e12 x C13 \/ 12 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.239\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 12\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 12\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 4 \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.239\u003cbr\u003ePDU metered 32A\/3P CEE 12x C13 \/ 12x C19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.239\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.239\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.239?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.239?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979239_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979239_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979239_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860186461,"sku":"7979239","price":782.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979239-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979240-pdu-metered","title":"Rittal DK 7979.240 PDU metered, 44x70 mm (WxD), number and type of sockets 36 x C13 \/ 6 x C19","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.240 (7979240)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 2,000 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,200 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 36 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947801\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.240\u003c\/strong\u003e (PDU metered; number and type of sockets 36 x C13 \/ 6 x C19) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ± 0.5 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,895 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e36 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 2,000 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.240\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 36\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1895 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.240\u003cbr\u003ePDU metered 16A\/3P CEE 36x C13 \/ 6x C19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.240\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.240\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.240?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.240?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979240_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979240_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979240_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860219229,"sku":"7979240","price":724.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979240-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979242-pdu-metered","title":"Rittal DK 7979.242 PDU metered, 44x70 mm (WxD), number and type of sockets 42 x C13","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.242 (7979242)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 42 x C13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947818\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.242\u003c\/strong\u003e (PDU metered; number and type of sockets 42 x C13) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e42 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947818\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.242\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 42\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 14\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.242\u003cbr\u003ePDU metered 16A\/3P CEE 42x C13\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.242\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.242\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.242?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.242?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979242_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979242_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979242_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860251997,"sku":"7979242","price":707.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979242-pdu-metered.jpg?v=1793628208"},{"product_id":"rittal-dk-7979256-pdu-metered","title":"Rittal DK 7979.256 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 4 x C19, 230 V AC","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.256 (7979256)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 4 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177967946\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.256\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x C13 \/ 4 x C19, 230 V AC) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack, and additionally residual current measurement per fuse.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eMetered PDU with integrated residual current measurement (RCM \/ Type B). The residual current is measured per 16 A fuse.\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003cbr\u003eIncl. RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eResidual current measurement (Type B – AC\/DC) per fuse, measuring range 0 mA – 100 mA\u003cbr\u003eEnergy metering per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 4 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177967946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.256\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eThe PDU has an all-current-sensitive residual current measurement (RCM Type B) per circuit breaker\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eThis changes the PDU length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse): 24 \/ 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse): 6 \/ 3\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 2\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eResidual current measurement (RCM) per circuit breaker 2 measuring points; AC + DC (RCM Type B) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.256\u003cbr\u003ePDU metered 32A\/1P CEE 24xC13 \/ 6xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.256\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.256\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.256?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.256?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979256_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979256_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860284765,"sku":"7979256","price":948.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979256-pdu-metered-rcm.jpg?v=1793628208"},{"product_id":"rittal-dk-7979276-pdu-metered","title":"Rittal DK 7979.276 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 6 x C19, 400 V AC","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.276 (7979276)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177967939\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.276\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x C13 \/ 6 x C19, 400 V AC) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack, and additionally residual current measurement per phase.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eMetered PDU with integrated residual current measurement (RCM \/ Type B). The residual current is measured per phase.\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ± 0.5 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003cbr\u003eIncl. RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eEnergy metering per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177967939\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7979.276\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eThe PDU has an all-current-sensitive residual current measurement (RCM Type B) per phase\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eThis changes the PDU length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1695 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eResidual current measurement (RCM) per phase 3 measuring points; AC + DC (RCM Type B) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.276\u003cbr\u003ePDU metered 16A\/3P CEE 24xC13 \/ 6xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.276\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.276\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.276?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.276?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979276_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979276_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860317533,"sku":"7979276","price":1249.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979276-pdu-metered.jpg?v=1793628209"}],"url":"https:\/\/www.iam24.de\/en\/collections\/rittal-power-distribution-unit-pdu.oembed?page=2","provider":"IAM24","version":"1.0","type":"link"}