{"title":"Rittal Small Cooling Units","description":"\u003cp\u003eRittal Small Cooling Units at IAM24: 13 genuine Rittal articles. The article number (e.g. SV 3569.005 or 3569005) and the data sheet are shown on every product page.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/en\/collections\/rittal#produktgruppen\"\u003eAll Rittal product groups\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/rittal\"\u003eAll Rittal products\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"rittal-sk-3166115-dachluefter-fuer-vx-it-ts-it","title":"Rittal SK 3166.115 roof-mounted fan for VX IT, TS IT, 470x200x470 mm, 100 V - 130 V, 1~","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3166.115 (3166115)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 470 x 200 x 470 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 100 V - 130 V, 1~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966260\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3166.115\u003c\/strong\u003e (roof-mounted fan for VX IT, TS IT; 100 V - 130 V, 1~) has external dimensions of 470 x 200 x 470 mm (W x H x D). Roof-mounted fan for the office environment with very low noise level of 39 dB(A) and high volume flow (free-blowing 1245 to 1345 m³\/h).\u003c\/p\u003e\u003cp\u003eThe roof-mounted fan for VX IT and TS IT is intended for the office environment. It is notable for a very low noise level of 39 dB(A) and a high volume flow (free-blowing 1245 to 1345 m³\/h). The speed-controlled fan adapts its output optimally to actual demand.\u003c\/p\u003e\u003cp\u003eThe roof-mounted fan is pre-assembled and wired ready for connection, and is supplied as a fan unit with speed controller, fixing material and installation and quick-start instructions, without roof plate. The material is painted sheet steel; the protection category is IP 20 to EN 60 529.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal fan with speed controller:\u003c\/strong\u003e Speed-controlled fan for temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSheet steel material:\u003c\/strong\u003e Painted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature range:\u003c\/strong\u003e 5 °C...55 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply included:\u003c\/strong\u003e Fan unit, speed controller, fixing material, instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertificates on file:\u003c\/strong\u003e Declaration of conformity and UL + C-UL (listed).\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eVery quiet and therefore suitable for the office environment\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003eSpeed controller\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003cli\u003eWithout roof plate\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3166115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAreas of use\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003efor the office environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMode of operation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eThe speed-controlled fan adapts its output optimally to actual demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003eSpeed controller\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003cbr\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 V - 130 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote on art. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow rate to 800 m³\/h at 40 Pa back pressure when using two ventilated plinth trim panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.5 A\u003cbr\u003eAt 60 Hz: 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003epre-assembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 470 mm\u003cbr\u003eHeight: 200 mm\u003cbr\u003eDepth: 470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMounting cut-out\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth:410 mm\u003cbr\u003eDepth: 410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to EN 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSpeed-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRated power L35 L35\/50 Hz: 24 W\u003cbr\u003eRated power L35 L35\/60 Hz: 24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1,245 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e800 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11.267 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11.86 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK roof-mounted fan 100-130 V, 50-60 Hz\u003cbr\u003eArt. no. SK 3166.115\u003cbr\u003e**\u003cbr\u003eRoof-mounted fan for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 410x410 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. centrifugal fan, speed controller, fixing material and\u003cbr\u003einstallation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e100-130 V, 1~, 50\/60 Hz\u003cbr\u003eRated power: 24 W at 50\/60 Hz\u003cbr\u003eRated current (max.) at 50\/60 Hz: 0.5 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eAir flow rate free-blowing:\u003cbr\u003e1245 m³\/h, 50\/60 Hz\u003cbr\u003eAir flow at operating point:\u003cbr\u003e800 m³\/h at 40 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point:\u003cbr\u003e39 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm:\u003cbr\u003e470x200x470 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 9005 matt, fine texture\u003cbr\u003eArt. no. SK 3166.115\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3166.115\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3166.115?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 470 x 200 x 470 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 3166.115 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3166.115?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, speed controller, wired ready for connection, incl. fixing material, installation and quick-start instructions, without roof plate.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs a roof plate included in the scope of supply of the roof-mounted fan?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eNo, the roof-mounted fan is supplied without roof plate.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 3166.115?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9138\/3166115_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377119301981,"sku":"3166115","price":622.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3166115-sk-dachluefter-fuer-vx-it-fuer-den-officebereich.jpg?v=1793628477"},{"product_id":"rittal-sk-3166230-dachluefter-fuer-vx-it-ts-it","title":"Rittal SK 3166.230 roof-mounted fan for VX IT, TS IT, 470x200x470 mm, 200 V - 240 V, 1~","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3166.230 (3166230)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 470 x 200 x 470 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 200 V - 240 V, 1~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966277\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3166.230\u003c\/strong\u003e (roof-mounted fan for VX IT, TS IT; 200 V - 240 V, 1~) has external dimensions of 470 x 200 x 470 mm (W x H x D). Roof-mounted fan for the office environment with very low noise level of 39 dB(A) and high volume flow (free-blowing 1245 to 1345 m³\/h).\u003c\/p\u003e\u003cp\u003eThe roof-mounted fan for VX IT and TS IT is intended for the office environment. It is notable for a very low noise level of 39 dB(A) and a high volume flow (free-blowing 1245 to 1345 m³\/h). The speed-controlled fan adapts its output optimally to actual demand.\u003c\/p\u003e\u003cp\u003eThe roof-mounted fan is pre-assembled and wired ready for connection, and is supplied as a fan unit with speed controller, fixing material and installation and quick-start instructions, without roof plate. The material is painted sheet steel; the protection category is IP 20 to EN 60 529.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal fan with speed controller:\u003c\/strong\u003e Speed-controlled fan for temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSheet steel material:\u003c\/strong\u003e Painted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature range:\u003c\/strong\u003e 5 °C...55 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply included:\u003c\/strong\u003e Fan unit, speed controller, fixing material, instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertificates on file:\u003c\/strong\u003e Declaration of conformity and UL + C-UL (listed).\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eVery quiet and therefore suitable for the office environment\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003eSpeed controller\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003cli\u003eWithout roof plate\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3166230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAreas of use\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003efor the office environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMode of operation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eThe speed-controlled fan adapts its output optimally to actual demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003eSpeed controller\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003cbr\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e200 V - 240 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote on art. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow rate to 950 m³\/h at 40 Pa back pressure when using two ventilated plinth trim panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.3 A\u003cbr\u003eAt 60 Hz: 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003epre-assembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 470 mm\u003cbr\u003eHeight: 200 mm\u003cbr\u003eDepth: 470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMounting cut-out\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth:410 mm\u003cbr\u003eDepth: 410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to EN 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSpeed-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRated power L35 L35\/50 Hz: 30 W\u003cbr\u003eRated power L35 L35\/60 Hz: 30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1,345 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e950 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11.362 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK roof-mounted fan 200-240 V, 50-60 Hz\u003cbr\u003eArt. no. SK 3166.230\u003cbr\u003e**\u003cbr\u003eRoof-mounted fan for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 410x410 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. centrifugal fan, speed controller, fixing material and\u003cbr\u003einstallation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e200-240 V, 1~, 50\/60 Hz\u003cbr\u003eRated power: 30 W at 50\/60 Hz\u003cbr\u003eRated current (max.) at 50\/60 Hz: 0.3 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eAir flow rate free-blowing:\u003cbr\u003e1345 m³\/h, 50\/60 Hz\u003cbr\u003eAir flow at operating point:\u003cbr\u003e950 m³\/h at 40 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point: 39 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm: 470x200x470 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 7035 textured\u003cbr\u003eArt. no. SK 3166.230\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3166.230\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 3166.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 470 x 200 x 470 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 3166.230 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3166.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, speed controller, wired ready for connection, incl. fixing material, installation and quick-start instructions, without roof plate.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs a roof plate included in the scope of supply of the roof-mounted fan?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eNo, the roof-mounted fan is supplied without roof plate.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 3166.230?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9138\/3166230_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377119334749,"sku":"3166230","price":599.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3166230-sk-dachluefter-fuer-vx-it-fuer-den-officebereich.jpg?v=1793628477"},{"product_id":"rittal-sk-3301391-19-luftkanal-fuer-horizontale-luftfuehrung","title":"Rittal SK 3301.391 19\" air duct for horizontal air routing","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.391 (3301391)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177716629\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.391\u003c\/strong\u003e (19\" air duct for horizontal air routing) is a genuine Rittal article. For supplying cold air to switches mounted in the rear 19\" level.\u003c\/p\u003e\u003cp\u003eThe 19\" air duct for horizontal air routing is used to supply cold air to switches mounted in the rear 19\" level. It improves the air supply to the rear 19\" components and supports front-to-back air routing. An integrated brush strip allows cable entry of 19\" IT equipment, and the depth of the air duct is variable.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePainted sheet steel:\u003c\/strong\u003e material in RAL 9005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrush strip made of plastic:\u003c\/strong\u003e to UL 94-HB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse with switches:\u003c\/strong\u003e mounting in the rear 19\" level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall Cooling Units:\u003c\/strong\u003e accessories in the IT cooling category\u003c\/li\u003e\n\u003cli\u003eFor improved air supply to the rear 19\" components\u003c\/li\u003e\n\u003cli\u003eIntegrated brush strip for cable entry of 19\" IT equipment\u003c\/li\u003e\n\u003cli\u003eSupports front-to-back air routing\u003c\/li\u003e\n\u003cli\u003eVariable depth\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301391\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003cbr\u003eBrush strip: plastic, UL 94-HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 482.6 mm\u003cbr\u003eHeight: 1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e73269098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177716629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC011217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22410601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.391\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich components is the 19\" air duct used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe air duct is used to supply cold air to switches mounted in the rear 19\" level.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_5639\/3301391_Anleitung_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308504413,"sku":"3301391","price":121.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301391-sk-luftkanal.jpg?v=1793628709"},{"product_id":"rittal-sk-3301392-luftkanal-fuer-seitliche-luftfuehrung","title":"Rittal SK 3301.392 air duct for lateral air routing","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 3301.392 (3301392)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e TS IT · VX IT · Width: 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177716612\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 3301.392\u003c\/strong\u003e (air duct for lateral air routing) is a genuine Rittal article. For cold air supply to switches with lateral air intake.\u003c\/p\u003e\u003cp\u003eThe air duct for lateral air routing is used to supply cold air to switches with lateral air intake. It improves the air supply to 19\" IT equipment with lateral air routing, is variable in depth and has an integrated membrane grommet that allows cables to be routed through to the rear. The air duct belongs to the Small Cooling Units in the IT cooling range.\u003c\/p\u003e\u003cp\u003eThe air duct is made of painted sheet steel in RAL 9005. The scope of supply includes an adaptor for fixing to 19\" profile rails and a magnetic strip for covering the remaining vertical openings in the air baffle. It can only be mounted on the front 19\" installation level.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePainted sheet steel:\u003c\/strong\u003e material in RAL 9005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptor for 19\" profile rails:\u003c\/strong\u003e Included in the scope of supply for fixing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic strip included:\u003c\/strong\u003e Covers remaining vertical openings in the air baffle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeveral installation options:\u003c\/strong\u003e TS IT 19\" profile rails, TS IT 19\" mounting frames and 19\" profile rails, standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for TS IT\/VX IT:\u003c\/strong\u003e Enclosure type with width 800 mm\u003c\/li\u003e\n\u003cli\u003eFor improved air supply to 19\" IT equipment with lateral air routing\u003c\/li\u003e\n\u003cli\u003eIntegrated membrane grommet allows cables to be routed through to the rear\u003c\/li\u003e\n\u003cli\u003eVariable depth\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAir duct\u003c\/li\u003e\n\u003cli\u003eAdaptor for fixing to 19\" profile rails\u003c\/li\u003e\n\u003cli\u003eMagnetic strip for covering the remaining vertical openings in the air baffle\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 3301392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePainted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAir duct\u003cbr\u003eAdaptor for fixing to 19\" profile rails\u003cbr\u003eMagnetic strip for covering the remaining vertical openings in the air baffle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003efor TS IT 19\" profile rails\u003cbr\u003efor TS IT 19\" mounting frames\u003cbr\u003efor 19\" profile rails, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMounting note\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCan only be mounted on the front 19\" installation level\u003cbr\u003eCan only be mounted in the area of the vertical 19\" openings of the air baffle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 2 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: TS IT\u003cbr\u003eVX IT\u003cbr\u003eWidth: 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePCF\/PU (cradle-to-gate)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.9 kg CO2 eq (Cat B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e73269098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177716612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC011217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22410601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 3301.392\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 3301.392?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eAir duct, adaptor for fixing to 19\" profile rails, magnetic strip for covering the remaining vertical openings in the air baffle.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhere can the air duct for lateral air routing be mounted?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe air duct can only be mounted on the front 19\" installation level and only in the area of the vertical 19\" openings of the air baffle.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_5640\/3301392_Anleitung_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377308537181,"sku":"3301392","price":136.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-3301392-sk-luftkanal.jpg?v=1793628709"},{"product_id":"rittal-sk-5503010-lueftermodul-fuer-vx-it-ts-it","title":"Rittal SK 5503.010 fan module for VX IT, TS IT, 550x42x220 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 5503.010 (5503010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 550 x 42 x 220 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT · TS IT · TX CableNet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966253\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 5503.010\u003c\/strong\u003e (fan module for VX IT, TS IT) has external dimensions of 550 x 42 x 220 mm (W x H x D). For active ventilation. The unit can optionally be expanded with additional fans. Simple connection technology and energy-efficient speed control.\u003c\/p\u003e\u003cp\u003eThe fan module for VX IT and TS IT is used for active ventilation and is one of the Small Cooling Units in the IT cooling range. The unit is supplied wired ready for connection with two fans and can optionally be expanded with additional fans. In the version without roof plate, the fan module is inserted directly into the cut-out integrated in the roof plate.\u003c\/p\u003e\u003cp\u003eThe rated operational voltage is 100 V - 240 V at 1~ and 50 Hz\/60 Hz. The air flow rate at the operating point is 280 m³\/h, the sound pressure level 46 dB(A). The operating temperature range extends from 5 °C to 55 °C; the protection category is IP 20.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive ventilation:\u003c\/strong\u003e Speed-controlled fans, can optionally be expanded with further fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow rate at operating point:\u003c\/strong\u003e 280 m³\/h at 25 Pa back pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound pressure level at operating point:\u003c\/strong\u003e 46 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical protection:\u003c\/strong\u003e Upstream protection via miniature circuit breaker\/fuse 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded in the scope of supply:\u003c\/strong\u003e Fan unit with fans, fixing material and installation and quick-start instructions.\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003e2 fans\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 5503010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003e2 fans\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e280 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 V - 240 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.39 A\u003cbr\u003eAt 60 Hz: 0.36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 550 mm\u003cbr\u003eHeight: 42 mm\u003cbr\u003eDepth: 220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIn the VX IT with W x D (mm): 600 x 600 \/ 600 x 800 \/ 600 x 1000 \/ 600 x 1200 \/ 800 x 600\u003cbr\u003eIn the TS IT with W x D (mm): 600 x 600 \/ 600 x 800 \/ 600 x 1000 \/ 600 x 1200 \/ 800 x 600\u003cbr\u003eIn the TX CableNet with W x D (mm): 600 x 600 \/ 600 x 800 \/ 600 x 1000 \/ 600 x 1200 \/ 800 x 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow to 280 m³\/h at 25 Pa back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e46 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003cbr\u003eTS IT\u003cbr\u003eTX CableNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e21.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.653 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK fan module 100-240 V, 50-60 Hz\u003cbr\u003eArt. no. SK 5503.010\u003cbr\u003e**\u003cbr\u003eFan module for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 490x120 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. 2 axial fans with integrated speed controllers (expandable to max. 3 fans), fixing material and installation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e100-240 V, 1~, 50\/60 Hz\u003cbr\u003eRated power with 3 fans (max.):\u003cbr\u003e17 W at 50\/60 Hz\u003cbr\u003eRated current with 3 fans (max.) at 50\/60 Hz: 0.17 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eFree-blowing air flow: 400 m³\/h\u003cbr\u003eAir flow at operating point:\u003cbr\u003e280 m³\/h at 25 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point: 46 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm: 550x42x220 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 7035 textured\u003cbr\u003eArt. no. SK 5503.010\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 5503.010\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 5503.010?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 550 x 42 x 220 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 5503.010 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 5503.010?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, 2 fans, wired ready for connection, incl. fixing material, installation and quick-start instructions.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan the fan module be expanded with further fans?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the unit can optionally be expanded with additional fans.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 5503.010?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003cli\u003eUK declaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9139\/5503010_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9190\/5503010_Weitere_Anleitungen_DE\" target=\"_blank\" rel=\"noopener\"\u003eFurther instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377730818397,"sku":"5503010","price":146.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-5503010-sk-lueftermodul.jpg?v=1793628821"},{"product_id":"rittal-sk-5503020-lueftermodul-fuer-vx-it-ts-it","title":"Rittal SK 5503.020 fan module for VX IT, TS IT, 550x42x340 mm, RAL 7035","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 5503.020 (5503020)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 550 x 42 x 340 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT · TS IT · TX CableNet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966246\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 5503.020\u003c\/strong\u003e (fan module for VX IT, TS IT; RAL 7035) has external dimensions of 550 x 42 x 340 mm (W x H x D). For active ventilation. The unit can optionally be expanded with additional fans. Simple connection technology and energy-efficient speed control.\u003c\/p\u003e\u003cp\u003eThe fan module for VX IT and TS IT is used for active ventilation and is one of the Small Cooling Units in the IT cooling range. The unit is supplied wired ready for connection with two fans and can optionally be expanded with additional fans. In the version without roof plate, the fan module is inserted directly into the cut-out integrated in the roof plate.\u003c\/p\u003e\u003cp\u003eThe rated operational voltage is 100 V - 240 V at 1~ and 50 Hz\/60 Hz. The air flow rate at the operating point is 280 m³\/h, the sound pressure level 46 dB(A). The operating temperature range extends from 5 °C to 55 °C; the protection category is IP 20.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive ventilation:\u003c\/strong\u003e Speed-controlled fans, can optionally be expanded with further fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow rate at operating point:\u003c\/strong\u003e 280 m³\/h at 25 Pa back pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound pressure level at operating point:\u003c\/strong\u003e 46 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical protection:\u003c\/strong\u003e Upstream protection via miniature circuit breaker\/fuse 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded in the scope of supply:\u003c\/strong\u003e Fan unit with fans, fixing material and installation and quick-start instructions.\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003e2 fans\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 5503020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003e2 fans\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e280 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 V - 240 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.7 A\u003cbr\u003eAt 60 Hz: 0.69 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 550 mm\u003cbr\u003eHeight: 42 mm\u003cbr\u003eDepth: 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIn the VX IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003cbr\u003eIn the TS IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003cbr\u003eIn the TX CableNet with W x D (mm): 800 x 800 \/ 800 x 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow to 280 m³\/h at 25 Pa back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e46 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003cbr\u003eTS IT\u003cbr\u003eTX CableNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e42.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966246\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK fan module 100-240 V, 50-60 Hz\u003cbr\u003eArt. no. SK 5503.020\u003cbr\u003e**\u003cbr\u003eFan module for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 490x260 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. 2 axial fans with integrated speed controllers (expandable to max. 6 fans), fixing material and installation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e100-240 V, 1~, 50\/60 Hz\u003cbr\u003eRated power with 6 fans (max.): 34 W at 50\/60 Hz\u003cbr\u003eRated current with 6 fans (max.) at 50\/60 Hz: 0.34 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eFree-blowing air flow: 400 m³\/h\u003cbr\u003eAir flow at operating point:\u003cbr\u003e280 m³\/h at 25 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point: 46 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm: 550x42x340 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 7035 textured\u003cbr\u003eArt. no. SK 5503.020\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 5503.020\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 5503.020?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 550 x 42 x 340 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 5503.020 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 5503.020?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, 2 fans, wired ready for connection, incl. fixing material, installation and quick-start instructions.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan the fan module be expanded with further fans?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the unit can optionally be expanded with additional fans.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 5503.020?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003cli\u003eUK declaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9139\/5503020_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9190\/5503020_Weitere_Anleitungen_DE\" target=\"_blank\" rel=\"noopener\"\u003eFurther instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377730982237,"sku":"5503020","price":180.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-5503020-sk-lueftermodul.jpg?v=1793628821"},{"product_id":"rittal-sk-5503025-lueftermodul-fuer-vx-it-ts-it","title":"Rittal SK 5503.025 fan module for VX IT, TS IT, 550x42x340 mm, RAL 9005","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 5503.025 (5503025)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 550 x 42 x 340 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT · TS IT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e RAL 9005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966239\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 5503.025\u003c\/strong\u003e (fan module for VX IT, TS IT; RAL 9005) has external dimensions of 550 x 42 x 340 mm (W x H x D). For active ventilation. The unit can optionally be expanded with additional fans. Simple connection technology and energy-efficient speed control.\u003c\/p\u003e\u003cp\u003eThe fan module for VX IT and TS IT is used for active ventilation and is one of the Small Cooling Units in the IT cooling range. The unit is supplied wired ready for connection with two fans and can optionally be expanded with additional fans. In the version without roof plate, the fan module is inserted directly into the cut-out integrated in the roof plate.\u003c\/p\u003e\u003cp\u003eThe rated operational voltage is 100 V - 240 V at 1~ and 50 Hz\/60 Hz. The air flow rate at the operating point is 280 m³\/h, the sound pressure level 46 dB(A). The operating temperature range extends from 5 °C to 55 °C; the protection category is IP 20.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive ventilation:\u003c\/strong\u003e Speed-controlled fans, can optionally be expanded with further fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow rate at operating point:\u003c\/strong\u003e 280 m³\/h at 25 Pa back pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound pressure level at operating point:\u003c\/strong\u003e 46 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical protection:\u003c\/strong\u003e Upstream protection via miniature circuit breaker\/fuse 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded in the scope of supply:\u003c\/strong\u003e Fan unit with fans, fixing material and installation and quick-start instructions.\u003c\/li\u003e\n\u003cli\u003eSimple connection technology with C13 IEC appliance socket\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 fan unit\u003c\/li\u003e\n\u003cli\u003e2 fans\u003c\/li\u003e\n\u003cli\u003eReady-wired\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 5503025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 fan unit\u003cbr\u003e2 fans\u003cbr\u003eReady-wired\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e280 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 V - 240 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.7 A\u003cbr\u003eAt 60 Hz: 0.69 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 550 mm\u003cbr\u003eHeight: 42 mm\u003cbr\u003eDepth: 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBack-up fuse\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCircuit breaker\/fuse: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInstallation options\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIn the VX IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003cbr\u003eIn the TS IT with W x D (mm): 800 x 800 \/ 800 x 1000 \/ 800 x 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow to 280 m³\/h at 25 Pa back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e46 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT\u003cbr\u003eTS IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e42.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK fan module 100-240 V, 50-60 Hz\u003cbr\u003eArt. no. SK 5503.025\u003cbr\u003e**\u003cbr\u003eFan module for active ventilation of an enclosure.\u003cbr\u003eInstalled directly in the cut-out integrated in the roof plate with\u003cbr\u003edimensions WxD 490x260 mm.\u003cbr\u003eCan be used, e.g., for manufacturer Rittal, enclosure series VX IT, TS IT.\u003cbr\u003eComplete unit ready for connection with C13 IEC appliance socket\u003cbr\u003eIncl. 2 axial fans with integrated speed controllers (expandable to max. 6 fans), fixing material and installation instructions.\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage:\u003cbr\u003e100-240 V, 1~, 50\/60 Hz\u003cbr\u003eRated power with 6 fans (max.): 34 W at 50\/60 Hz\u003cbr\u003eRated current with 6 fans (max.) at 50\/60 Hz: 0.34 A\u003cbr\u003eMiniature fuse T 10 A, 250 V, 5 x 20 mm integrated\u003cbr\u003eFree-blowing air flow: 400 m³\/h\u003cbr\u003eAir flow at operating point:\u003cbr\u003e280 m³\/h at 25 Pa, 50\/60 Hz\u003cbr\u003eSound pressure level at operating point: 46 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD in mm: 550x42x340 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: sheet steel, painted\u003cbr\u003eColour: RAL 9005 matt, fine texture\u003cbr\u003eArt. no. SK 5503.025\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 5503.025\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 5503.025?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 550 x 42 x 340 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 5503.025 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 5503.025?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003e1 fan unit, 2 fans, wired ready for connection, incl. fixing material, installation and quick-start instructions.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan the fan module be expanded with further fans?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the unit can optionally be expanded with additional fans.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal SK 5503.025?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eUL + C-UL (listed)\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003cli\u003eUK declaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9139\/5503025_Anleitung_CS_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (CS, DE, EN)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_9190\/5503025_Weitere_Anleitungen_DE\" target=\"_blank\" rel=\"noopener\"\u003eFurther instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377731277149,"sku":"5503025","price":180.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-5503025-sk-lueftermodul.jpg?v=1793628821"},{"product_id":"rittal-dk-7507760-abdeckplatte-fuer-luefterfelder-fuer-flatbox","title":"Rittal DK 7507.760 cover plate for fan panels for FlatBox (pack of 6)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7507.760 (7507760)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 6 pieces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177550841\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7507.760\u003c\/strong\u003e (cover plate for fan panels for FlatBox) is a genuine Rittal article and is supplied in packaging units of 6 pieces. For covering unused fan panels when using fan motors in the FlatBox.\u003c\/p\u003e\u003cp\u003eThe cover plate for fan panels is used to cover unused fan panels when using fan motors in the FlatBox. It is made of powder-coated sheet steel in RAL 7035 and is supplied including fixing material.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e covering unused fan panels in the FlatBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial and surface:\u003c\/strong\u003e sheet steel, powder-coated, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply:\u003c\/strong\u003e including fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7507760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSheet steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSurface\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePowder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePCF\/PU (cradle-to-gate)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.8 kg CO2 eq (Cat B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e73269098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177550841\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27189272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7507.760\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7507.760?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow many pieces does one packaging unit of the Rittal DK 7507.760 contain?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eOne packaging unit contains 6 pieces; the stated price applies per packaging unit.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7940\/7507760_Einlegezettel_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInsert leaflet\u003c\/a\u003e (DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377848619357,"sku":"7507760","price":18.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7507760-abdeckplatten-fuer-luefterfelder.jpg?v=1793628097"},{"product_id":"rittal-dk-7826750-ablufthaube-fuer-vx-vx-it","title":"Rittal DK 7826.750 exhaust hood for VX, VX IT, 450x144x300 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7826.750 (7826750)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 450 x 144 x 300 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177572300\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7826.750\u003c\/strong\u003e (exhaust hood for VX, VX IT) has external dimensions of 450 x 144 x 300 mm (W x H x D). For connecting closed racks to a ventilation system. The stepped connection is suitable for the common pipe diameters 150 mm and 200 mm and thus ensures effective cooling through targeted air exchange in the rack.\u003c\/p\u003e\u003cp\u003eThe exhaust hood for VX and VX IT is used to connect closed racks to a ventilation system. The stepped connection is suitable for the common pipe diameters 150 mm and 200 mm and thus ensures effective cooling through targeted air exchange in the rack. The hood is made of transparent PET-G; fixing material and seal are included in the scope of supply. A cut-out in the roof plate is required for mounting.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStepped connection:\u003c\/strong\u003e For the hose connections 150 mm and 200 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection of closed racks:\u003c\/strong\u003e To an existing central climate control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePET-G material:\u003c\/strong\u003e Transparent version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply of the hood:\u003c\/strong\u003e Fixing material and seal.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7826750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePET-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eTransparent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eØ hose connection\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e150 mm\u003cbr\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRequired cut-out in the roof plate (W x D): 380 x 230 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 450 mm\u003cbr\u003eHeight: 144 mm\u003cbr\u003eDepth: 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.959 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e39269097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177572300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27189272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Exhaust hood\u003cbr\u003e**\u003cbr\u003eFor connecting closed racks to an existing central climate control system. Stepped\u003cbr\u003econnection for pipe diameters 150 mm and 200 mm.\u003cbr\u003eMaximum cut-out in the roof plate 380 x 230 mm.\u003cbr\u003eMaterial:,,PET-G, transparent\u003cbr\u003eScope of supply: Including fixing material, seal\u003cbr\u003eDimensions W x H x D: ,,450 x 144 x 300 mm\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7826.750\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal DK 7826.750?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 450 x 144 x 300 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7826.750?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_5414\/7826750_Einlegezettel_DE_EN\" target=\"_blank\" rel=\"noopener\"\u003eInsert leaflet\u003c\/a\u003e (DE, EN)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377850257757,"sku":"7826750","price":89.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7826750-dachhaube-fuer-klimaanschluss.jpg?v=1793628153"},{"product_id":"rittal-sk-7980000-lueftererweiterungssatz","title":"Rittal SK 7980.000 fan extension kit, 119x119x38 mm, 230 V, 1~","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7980.000 (7980000)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 119 x 38 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 230 V, 1~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177137752\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7980.000\u003c\/strong\u003e (fan extension kit; 230 V, 1~) has external dimensions of 119 x 119 x 38 mm (W x H x D). For retrofitting various fan units or supplementing the fan plate.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit from the Small Cooling Units range is used for retrofitting various fan units or supplementing the fan plate. The scope of supply includes fan, connection cable (0.61 m) and fixing material.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofitting:\u003c\/strong\u003e Suitable for retrofitting various fan units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplement:\u003c\/strong\u003e Expansion of the fan plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply:\u003c\/strong\u003e Fan, connection cable (0.61 m) and fixing material.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eConnection cable (0.61 m)\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7980000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eConnection cable (0.61 m)\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate free-blowing (with non-woven filter)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 160 m³\/h\u003cbr\u003eAt 60 Hz: 180 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 15 W\u003cbr\u003eAt 60 Hz: 14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 119 mm\u003cbr\u003eDepth: 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-10 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 37 dB(A)\u003cbr\u003eAt 60 Hz: 37 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.671 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177137752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Fan extension kit for fan plate\u003cbr\u003e**\u003cbr\u003eRated operational voltage: 230 V;\u003cbr\u003eRated power: 19\/18 W at 50\/60 Hz;\u003cbr\u003eAir flow rate (free-blowing): 160-180 m3\/h, 50\/60\u003cbr\u003eHz; temperature range: -10°C to +55°C\u003cbr\u003eDimensions (W x H x D): 119 mm x 119 mm x 38 mm\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7980.000\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7980.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 119 x 38 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7980.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, connection cable (0.61 m), incl. fixing material.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_893\/7980000_Kennlinienfelder_DE\" target=\"_blank\" rel=\"noopener\"\u003eCharacteristic curves\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/7980000_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863004509,"sku":"7980000","price":35.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7980000-lueftererweiterungssatz-fuer-luefterblech.jpg?v=1793628821"},{"product_id":"rittal-sk-7980100-lueftererweiterungssatz","title":"Rittal SK 7980.100 fan expansion kit, 119x119x25 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7980.100 (7980100)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 119 x 25 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177187313\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7980.100\u003c\/strong\u003e (fan expansion kit) has external dimensions of 119 x 119 x 25 mm (W x H x D). For retrofitting various fan units or supplementing the fan plate.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit from the Small Cooling Units range is used for retrofitting various fan units or supplementing the fan plate. The scope of supply includes fan, connection cable (0.61 m) and fixing material.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofitting:\u003c\/strong\u003e Suitable for retrofitting various fan units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplement:\u003c\/strong\u003e Expansion of the fan plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply:\u003c\/strong\u003e Fan, connection cable (0.61 m) and fixing material.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eConnection cable (0.61 m)\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7980100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eConnection cable (0.61 m)\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate free-blowing (with non-woven filter)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 108 m³\/h\u003cbr\u003eAt 60 Hz: 120 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V, 1~, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 14 W\u003cbr\u003eAt 60 Hz: 12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 119 mm\u003cbr\u003eDepth: 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 34 dB(A)\u003cbr\u003eAt 60 Hz: 34 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.486 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177187313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Fan expansion kit for EL\u003cbr\u003e**\u003cbr\u003eRated operational voltage: 230 V;\u003cbr\u003eRated power: 14\/12 W at 50\/60 Hz;\u003cbr\u003eAir flow rate (free-blowing): 108\/120 m3\/h, 50\/60\u003cbr\u003eHz; temperature range: -20°C to +70°C\u003cbr\u003eDimensions (W x H x D): 119 mm x 119 mm x 25 mm\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7980.100\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7980.100?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 119 x 25 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7980.100?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, connection cable (0.61 m), incl. fixing material.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_893\/7980100_Kennlinienfelder_DE\" target=\"_blank\" rel=\"noopener\"\u003eCharacteristic curves\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/7980100_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863037277,"sku":"7980100","price":44.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7980100-lueftererweiterungssatz-fuer-el.jpg?v=1793628821"},{"product_id":"rittal-sk-7980148-lueftererweiterungssatz","title":"Rittal SK 7980.148 fan expansion kit, 119x119x38 mm, 48 V (DC)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7980.148 (7980148)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 119 x 38 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 48 V (DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177325234\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7980.148\u003c\/strong\u003e (fan expansion kit; 48 V (DC)) has external dimensions of 119 x 119 x 38 mm (W x H x D). For retrofitting various fan units or supplementing the fan plate.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit from the Small Cooling Units range is used for retrofitting various fan units or supplementing the fan plate. The scope of supply includes fan, connection cable (0.61 m) and fixing material.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofitting:\u003c\/strong\u003e Suitable for retrofitting various fan units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplement:\u003c\/strong\u003e Expansion of the fan plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScope of supply:\u003c\/strong\u003e Fan, connection cable (0.61 m) and fixing material.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eConnection cable (0.61 m)\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7980148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eConnection cable (0.61 m)\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow rate (free-blowing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e184 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e48 V (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power Pel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt DC: 7.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 119 mm\u003cbr\u003eDepth: 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt DC: 43 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.387 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177325234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Fan expansion kit WxHxD 119x119x38, 48 V\u003cbr\u003e**\u003cbr\u003eAir flow rate (free-blowing): 184 m3\/h\u003cbr\u003eHz; temperature range: -20°C to +70°C\u003cbr\u003eDimensions (W x H x D): 119 mm x 119 mm x 38 mm\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7980.148\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7980.148?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 119 x 38 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7980.148?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, connection cable (0.61 m), incl. fixing material.\u003c\/p\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_893\/7980148_Kennlinienfelder_DE\" target=\"_blank\" rel=\"noopener\"\u003eCharacteristic curves\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_6104\/7980148_Technisches_Systemhandbuch_DE\" target=\"_blank\" rel=\"noopener\"\u003eTechnical system manual\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863070045,"sku":"7980148","price":50.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7980148-lueftererweiterungssatz.jpg?v=1793628821"},{"product_id":"rittal-sk-7990000-lueftererweiterungssatz-fuer-vx-it-ts-it","title":"Rittal SK 7990.000 fan expansion kit for VX IT, TS IT, 119x25x119 mm","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e SK 7990.000 (7990000)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 119 x 25 x 119 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177966345\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal SK 7990.000\u003c\/strong\u003e (fan expansion kit for VX IT, TS IT) has external dimensions of 119 x 25 x 119 mm (W x H x D). Fan expansion kit with integrated speed controller for retrofitting in the fan modules 5503.010, 5503.020 and 5503.025.\u003c\/p\u003e\u003cp\u003eThe Rittal fan expansion kit for VX IT and TS IT with integrated speed controller is used for retrofitting in the fan modules. The version without roof plate is made of plastic in RAL 9005 and is designed for a rated operational voltage of 24 V (DC). The scope of supply includes fan, protective grille, fixing material and installation and quick-start instructions; a declaration of conformity is stated as proof.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating data:\u003c\/strong\u003e Rated power 7.7 W, rated operational voltage 24 V (DC), rated current max. 0.32 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow:\u003c\/strong\u003e 150 m³\/h at the operating point; the stated air flow applies at 25 Pa back pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection category:\u003c\/strong\u003e IP 20 to IEC 60 529.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e Sound pressure level 44 dB(A) at the operating point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e Operating temperature range 5 °C to 55 °C.\u003c\/li\u003e\n\u003cli\u003eReady-to-connect complete solution\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient speed control with preset characteristic curve\u003c\/li\u003e\n\u003cli\u003eInternational approvals and multi-voltage capability for worldwide use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFan\u003c\/li\u003e\n\u003cli\u003eProtective grille\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003cli\u003eInstallation and quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSK 7990000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout roof plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFan\u003cbr\u003eProtective grille\u003cbr\u003eIncl. fixing material\u003cbr\u003eInstallation and quick start guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAir flow (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e150 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 V (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAt 50 Hz: 0.32 A\u003cbr\u003eAt 60 Hz: 0.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 119 mm\u003cbr\u003eHeight: 25 mm\u003cbr\u003eDepth: 119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtection category IP to IEC 60 529\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSpeed\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNote\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eReduction of the stated air flow to 150 m³\/h at 25 Pa back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSound pressure level (at the operating point)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e44 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e7.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.308 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e84145915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177966345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27180716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**SK fan expansion kit\u003cbr\u003eArt. no. SK 7990.000\u003cbr\u003e**\u003cbr\u003eFan expansion kit for fan modules with integrated speed controller for installing and expanding\u003cbr\u003efan modules, e.g. Rittal make: SK 5503.XXX incl. fixing material, fan grille and installation instructions\u003cbr\u003eTech. data:\u003cbr\u003eRated operational voltage: 24 V DC\u003cbr\u003eRated power: 7.7 W\u003cbr\u003eRated current: 0.32 A\u003cbr\u003eAir flow at operating point:\u003cbr\u003e150 m³\/h @ 25 Pa,\u003cbr\u003eFree-blowing air flow: 192 m³\/h\u003cbr\u003eFree-blowing sound pressure level: 46 dB (A)\u003cbr\u003eOperating temperature range:\u003cbr\u003e+5°C to + 55°C\u003cbr\u003eDimensions WxHxD: 119x25x119 mm\u003cbr\u003eProtection category to IEC 60529: IP 20\u003cbr\u003eMaterial: plastic\u003cbr\u003eColour: RAL 9005\u003cbr\u003eArt. no. SK 7990.000\u003cbr\u003eManufacturer: Rittal\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal SK 7990.000\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the dimensions of the Rittal SK 7990.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe external dimensions are 119 x 25 x 119 mm (W x H x D).\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat protection category does the Rittal SK 7990.000 achieve?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIP 20 to EN 60 529.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal SK 7990.000?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eFan, protective grille, incl. fixing material, installation and quick-start instructions.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_15459\/7990000_Anleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377863102813,"sku":"7990000","price":33.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-sk-7990000-sk-lueftererweiterungssatz.jpg?v=1793628822"}],"url":"https:\/\/www.iam24.de\/en\/collections\/rittal-small-cooling-units.oembed","provider":"IAM24","version":"1.0","type":"link"}