{"title":"Safety relays","description":"\u003cp\u003e\u003cstrong\u003eSafety relays\u003c\/strong\u003e from GM International (GMI) are relay output modules with which a safety or process control system switches safety-related loads, such as solenoid valves or alarm devices. GMI describes them as modules for switching safety-related circuits up to SIL 3 for high-risk industries, with galvanic isolation between input and output.\u003c\/p\u003e\u003ch2\u003eFeatures according to GMI\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSwitching of safety-related circuits up to SIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between input and output contacts\u003c\/li\u003e\n\u003cli\u003eVersions for NE loads (de-energise to trip) and for ND or F\u0026amp;G loads (energise to trip)\u003c\/li\u003e\n\u003cli\u003eCompatible with the pulse testing of process control systems (DCS\/PLC), without flickering of contacts and LEDs\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eVersions with line and load diagnostics (LFD) for short circuit and open circuit\u003c\/li\u003e\n\u003cli\u003eMounting on 35 mm DIN rail or on a termination board\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eVersions at IAM24\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6;width:35%\"\u003eD5090, D5091, D5094 to D5098\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eD5000 series, relay output modules for 5 A loads (NE, ND or NE\/ND), some with LFD; variants for other drive voltages and low-power versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eD5290, D5291\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eD5000 series, for 10 A loads; variants for 48 V DC, 110 V DC, 115 V AC and 230 V AC, among others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eD5293, D5294, D5295\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eD5000 series, for 5 A loads with LFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eD5093\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eTransistor failure detector for input signals 24 to 220 V AC\/DC, SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eD5099\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRelay output module for 5 A loads without SIL rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eD1092, D1093\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eD1000 series, SIL 3 relay output modules for DIN rail, D1093 with line and load diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eX1-NIS-RLO\/EM and \/SS\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eX1 series, electromagnetic relays (EM) or solid-state relays (SS) for 2 A loads, SIL 2 or SIL 3, some with diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eYou will find further modules on the pages \u003ca href=\"\/en\/collections\/gmi-serie-d5000\"\u003eGMI D5000 series\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/gmi-serie-d1000\"\u003eGMI D1000 series\u003c\/a\u003e. We explain what NE and ND loads mean and which relay suits your application in the article \u003ca href=\"\/en\/blogs\/news\/gmi-sicherheitsrelais-funktion-und-auswahl\"\u003eGMI safety relays: function, applications and selection\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003ePrices plus shipping; VAT is shown according to the delivery country. All technical data are provided by GMI.\u003c\/p\u003e","products":[{"product_id":"d1092d","title":"D1092D safety relays SIL 3 relay output module DIN rail model D1092D","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0091\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"product-description\"\u003e\n    \u003ch2\u003eG.M. International D1092D – SIL 3 relay output module (dual-channel)\u003c\/h2\u003e\n    \n    \u003cp\u003e\n        The \u003cstrong\u003eD1092D\u003c\/strong\u003e from G.M. International is a highly reliable, dual-channel relay module for DIN rail mounting. It was developed specifically for switching safety-related circuits up to a level of \u003cstrong\u003eSIL 3\u003c\/strong\u003e in accordance with IEC 61508. \n        The module provides safe isolation between control signals (e.g. from a DCS or PLC) and the load in the field.\n    \u003c\/p\u003e\n\n    \u003ch3\u003eOutstanding features\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHighest safety level:\u003c\/strong\u003e Certified for SIL 3 \/ SC 3 applications – ideal for high-risk industries.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDual-channel flexibility:\u003c\/strong\u003e Two completely independent and isolated channels in a compact 22.5 mm enclosure.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVersatile contact configuration:\u003c\/strong\u003e Each channel offers one SPST contact for “Normally Energized” (NE) loads and one for “Normally De-energized” (ND) loads.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHigh switching capacity:\u003c\/strong\u003e Switches loads up to 5 A (inrush current) or 3 A continuous current at 250 Vac or 120 W at DC.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRobust insulation:\u003c\/strong\u003e Complete galvanic isolation between input and output contacts as well as between the two channels.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eZone 2 installation:\u003c\/strong\u003e Approved for installation in hazardous areas of Zone 2 \/ Division 2.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eTechnical data (excerpt)\u003c\/h3\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n        \u003ctbody\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eInput voltage (nominal)\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC (range 20.4 to 27.6 V DC)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eNumber of channels\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 (completely independent)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMax. contact load\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 A, 250 Vac, 750 VA \/ 3 A, 125 Vdc, 120 W\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eResponse\/release time\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTypically 5 ms \/ 3 ms\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-20 to +60 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eEnclosure dimensions\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWidth 22.5 mm, depth 99 mm, height 114.5 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIL 3, ATEX, IECEx, FM \u0026amp; FM-C, TUV\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\n    \u003ch3\u003eFields of application\u003c\/h3\u003e\n    \u003cp\u003e\n        Typical areas of use for the D1092D are \u003cstrong\u003eemergency shutdown systems (ESD)\u003c\/strong\u003e, fire protection systems and the control of critical valves or motors in the chemical and pharmaceutical industries as well as oil and gas production.\n    \u003c\/p\u003e\n\n    \u003cp style=\"font-size: 0.9em; color: #666; margin-top: 20px;\"\u003e\n        \u003cem\u003eRely on G.M. International for functional safety at the highest level.\u003c\/em\u003e\n    \u003c\/p\u003e\n\u003c\/div\u003e","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527967588701,"sku":"D1092D","price":221.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0616_R00_329731d4-d83a-43dc-9f23-f07a44c82679.jpg?v=1772119071"},{"product_id":"d1092d-069","title":"D1092D-069 safety relays SIL 3 relay output module DIN rail – model D1092D-069","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0101\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092D-069\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe single- and two-channel DIN rail relay outputs D1092S-069 and D1092D-069 are suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk industries. Galvanic isolation is ensured between the input and output contacts and between the two channels of the D1092D-069. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (system-to-system signalling, driving LEDs, etc.).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL3\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• 2 fully independent channels\n\n\n\u003cbr\u003e• 1 SPST normally closed and 1 SPST normally open contacts per channel\n\n\n\u003cbr\u003e• Inrush current: 5 A at 30 V DC \/ 250 V AC\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -20...+60 °C \u003cbr\u003e• Volt-free SPST NO+SPST NC relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527968178525,"sku":"D1092D-069","price":238.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1167_R00_4a7e07b3-2cee-4bbd-aba5-913fc73f4f7b.jpg?v=1772119072"},{"product_id":"d1092s","title":"D1092S safety relays SIL 3 relay output module DIN rail model D1092S","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0091\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D1092S single-channel DIN rail relay module is suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk areas. It provides galvanic isolation between input and output contacts. The module has one SPST contact each for energised (NE) and de-energised (ND) loads. When de-energised, the contacts are closed; when switched de-energised, they are open. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL3\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• One SPST contact each for the NE load and the ND load per channel.\n\n\n\u003cbr\u003e• Inrush current: 5 A at 30 V DC \/ 250 V AC.\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• Volt-free 1+1 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527968833885,"sku":"D1092S","price":141.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0745_R00_3f02fab2-bd39-4087-aad8-9bb3b56cc704.jpg?v=1772119073"},{"product_id":"d1092s-069","title":"D1092S-069 safety relays SIL 3 relay output module DIN rail – model D1092S-069","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0101\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092S-069\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe single- and two-channel DIN rail relay outputs D1092S-069 and D1092D-069 are suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk industries. Galvanic isolation is ensured between the input and output contacts and between the two channels of the D1092D-069. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (system-to-system signalling, driving LEDs, etc.).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL3\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• One SPST normally closed and one SPST normally open contact per channel.\n\n\n\u003cbr\u003e• Inrush current: 5 A at 30 V DC \/ 250 V AC.\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -20...+60 °C \u003cbr\u003e• Volt-free SPST NO+SPST NC relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527969653085,"sku":"D1092S-069","price":156.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1168_R00_c5429bd8-3840-421c-96e8-36c3ba05f755.jpg?v=1772119073"},{"product_id":"d1093s","title":"Safety relays D1093S SIL 3 relay output module with – line and load diagnostics DIN rail mounting – model D1093S","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0093\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1093S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D1093S single-channel DIN rail relay module is suitable for switching safety-related circuits up to SIL 3 in accordance with IEC 61508:2010 Ed. 2 for high-risk industries. It provides galvanic isolation between input and output contacts. The module has one DPST contact for energised (NE) loads and one SPST contact for de-energised (ND) loads. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL2\/SC3\n\u003cbr\u003e• Installation in Zone 2, Division 2\n\u003cbr\u003e• Line and load open-circuit diagnostics in NE and ND states\n\n\n\u003cbr\u003e• DPST contact for NE load and 1 SPST contact for ND load\n\n\n\u003cbr\u003e• 5 A inrush current at 30 V DC \/ 250 V AC\u003cbr\u003e\u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ trip by energising \u003cbr\u003e• 3 A \u003cbr\u003e• 125 V DC \u003cbr\u003e• -20...+60 °C \u003cbr\u003e• 1 DPST for NE loads \u003cbr\u003e• SIL3 \u003cbr\u003e• D1000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527970242909,"sku":"D1093S","price":348.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0617_R00_5cddb345-ee69-4ce5-8985-e0159d378f92.jpg?v=1772119074"},{"product_id":"d5090s","title":"D5090S safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0109\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5090 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. For de-energised (NE) loads, two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: an internal circuit allows testing with drive pulses and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528015692125,"sku":"D5090S","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0363_R01_4ee36052-1e19-476f-bb3d-9311064c3944.png?v=1772119195"},{"product_id":"d5090s-086","title":"D5090S-086 safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0267\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S-086\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5090-086 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. For de-energised loads (NE), two NC contacts are available to isolate the load on both supply lines, plus one NO contact for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: an internal circuit allows testing with drive pulses and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528016937309,"sku":"D5090S-086","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0360_R00_86e70422-5623-403b-8a8b-881f43fa41c5.jpg?v=1772119193"},{"product_id":"d5090s-102","title":"D5090S-102 safety relays SIL3 relay output low-power module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0456\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S-102\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5090-102 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. This model is designed specifically for high functional safety with minimal power consumption and low input voltage. Compatibility with certain double-connector cards (DO cards) with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Low power consumption\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528017527133,"sku":"D5090S-102","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0639_R01_a360c3a6-db91-4463-820a-ff2f82cc9afb.png?v=1772119198"},{"product_id":"d5091s","title":"D5091S safety relays SIL3 relay output module for 5 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0110\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5091S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5091 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, one normally open (NO) and one normally closed (NC) contact are available, optionally with energised or de-energised coil. A service contact is also provided. Thanks to extensive compatibility with various process control systems (DCS\/PLC), precise drive pulse testing is possible through an internal circuit that prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for ND\/F\u0026amp;G loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528017690973,"sku":"D5091S","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0364_R00_d022ffb0-d100-4dfe-8d14-4547a1e48c33.jpg?v=1772119196"},{"product_id":"d5091s-103","title":"D5091S-103 safety relays SIL3 relay output low-power module for 5 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0457\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5091S-103\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5091-103 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, one normally open (NO) and one normally closed (NC) contact are available, optionally with energised or de-energised coil. A service contact is also provided. This model is designed specifically for high functional safety with minimal power consumption and low input voltage. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for ND\/F\u0026amp;G loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low power consumption\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528019820893,"sku":"D5091S-103","price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0640_R01_41c48166-7739-48e2-abf3-3ac4d095d940.png?v=1772119204"},{"product_id":"d5093d","title":"D5093D safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0175\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093 module, a transistor output detector for 24\/220 V DC\/V AC, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel signals the presence of a 24 to 220 V AC\/DC input signal at the output by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output). The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• Double galvanically isolated inputs\/outputs\n\u003cbr\u003e• High packing density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528020902237,"sku":"D5093D","price":211.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0359_R00_e9b1efca-2ca1-4f68-b6f7-bf088778333a.jpg?v=1772119202"},{"product_id":"d5093d-tb","title":"D5093D-TB safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0541\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093D-TB\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093-TB module, a 24\/220 V DC\/AC transistor output detector, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel can signal the presence of a 24 to 220 V AC\/DC input signal by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output) at the output. The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• 2 fully independent channels\n\u003cbr\u003e• Double galvanically isolated inputs\/outputs\n\u003cbr\u003e• High packing density, two channels per unit\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528022344029,"sku":"D5093D-TB","price":203.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1128_R00_9c3e7c34-9c25-4fff-8a61-bd4c03c15124.png?v=1772119211"},{"product_id":"d5093s","title":"D5093S safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0175\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093 module, a transistor output detector for 24\/220 V DC\/V AC, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel signals the presence of a 24 to 220 V AC\/DC input signal at the output by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output). The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Two-port isolation, input\/output\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528023195997,"sku":"D5093S","price":132.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0358_R00_a4d2a9a1-39b7-4fe6-a0fe-7dd9faa69219.jpg?v=1772119209"},{"product_id":"d5093s-tb","title":"D5093S-TB safety relays SIL3 24\/220 V DC\/AC transistor failure detector","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0541\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093S-TB\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5093-TB module, a 24\/220 V DC\/AC transistor output detector, is suitable for applications requiring SIL 3 in safety-related systems for high-risk industries. Each channel can signal the presence of a 24 to 220 V AC\/DC input signal by closing an optically coupled normally closed transistor (solid-state relay, MOSFET output) at the output. The presence of the input signal is additionally indicated by a yellow LED on the front panel. The input switching voltages are selected according to the applied input signal via an internal DIP switch (overload-protected).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Two-port isolation, input\/output\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528025751901,"sku":"D5093S-TB","price":128.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1129_R00_a86b83ab-d6b7-4398-84da-f46a68082c88.png?v=1772119217"},{"product_id":"d5094s","title":"D5094S safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0299\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5094S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5094 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for energised (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Broad compatibility with various process control systems (DCS) and programmable logic controllers (PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528026407261,"sku":"D5094S","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0361_R00.jpg?v=1793959541"},{"product_id":"d5094s-104","title":"D5094S-104 safety relays SIL3 low-voltage relay module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0460\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5094S-104\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5094-104 relay module is suitable for switching safety-related circuits up to safety level SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for both de-energised (NE) and dead (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528026833245,"sku":"D5094S-104","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0641_R01_fb498dd0-e62d-4304-8086-d910f7ee0a25.png?v=1772119223"},{"product_id":"d5095s","title":"D5095S safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0300\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5095S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5095 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It ensures galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 NC relay contacts are available, connected in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for both energised (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528028438877,"sku":"D5095S","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0362_R00_a06feb8f-97ae-4b35-851f-e2a7111be7bb.jpg?v=1772119221"},{"product_id":"d5095s-105","title":"D5095S-105 safety relays SIL3 low-voltage relay module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0461\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5095S-105\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5095-105 relay module is suitable for switching safety-related circuits up to safety level SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 NC relay contacts are available, connected first in parallel and then in series. The high process availability is ensured by the SIL 3 safety function for both de-energised (NE) and dead (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low input voltage\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528030077277,"sku":"D5095S-105","price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0642_R01_d8f9da3a-3086-47c6-ad78-5d166cd88f9e.png?v=1772119228"},{"product_id":"d5096s","title":"D5096S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0301\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5096 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by an SIL 3 safety function for voltage-free (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Wide compatibility with various process control systems (DCS) and PLCs is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit and open-circuit detection as well as load voltage monitoring are possible both in the de-energised and in the energised state. The fault in the field is transmitted directly to the PLC output DO and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC output\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528034173277,"sku":"D5096S","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0365_R00_1217c712-3780-40af-9bba-29ac6c4d8595.jpg?v=1772119225"},{"product_id":"d5096s-100","title":"D5096S-100 safety relay SIL3\/2 5 A relay with LFD and universal fault mirroring","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0439\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S-100\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5096-100 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by the SIL 3 safety function for voltage-free (NE) loads and SIL 2 for de-energised (ND)\/F\u0026amp;G loads. The load can be isolated from the supply network in both polarities. Wide compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit\/open-circuit detection in the line and load as well as monitoring of the load voltage are possible with the load both energised and de-energised. The fault in the field is mirrored directly to the PLC DO connection by opening the input and is additionally reported by opening the fault output. This fault mirroring technique ensures wide compatibility with PLC DO cards.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for ND loads with ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Universal fault mirroring to the PLC DO\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528035647837,"sku":"D5096S-100","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0372_R00_a7415f01-a3d9-4420-9c14-84ed8609d473.jpg?v=1772119227"},{"product_id":"d5096s-106","title":"D5096S-106 Safety relay SIL3 Low-voltage relay module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0462\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S-106\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5096-106 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by an SIL 3 safety function for both voltage-controlled (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage. Short-circuit and open-circuit detection on line and load as well as load voltage monitoring are integrated in both the de-energised and the energised state. The fault in the field is transmitted directly to the PLC output (DO) and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low input voltage\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC output\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528037253469,"sku":"D5096S-106","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0643_R01_70916b2b-9c88-4a2c-9086-0a9078da891e.png?v=1772119232"},{"product_id":"d5097s","title":"D5097S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0302\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5097S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5097 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has 2+2 NC relay contacts connected in parallel and then in series to avoid false tripping and increase process availability. The SIL 3 safety function ensures high process availability for both voltage-controlled (NE) and voltage-free (ND) loads (F\u0026amp;G). The load can be isolated from the supply in both polarities. Wide compatibility with various DCS\/PLC is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit\/open-circuit detection on line and load as well as monitoring of the load voltage are possible both with the load energised and de-energised. The fault in the field is transmitted directly to the PLC DO output and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC DO\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528038138205,"sku":"D5097S","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0366_R00_268dd28b-7d0e-412e-a226-087208b24564.jpg?v=1772119230"},{"product_id":"d5097s-107","title":"D5097S-107 Safety relay SIL3 Low-voltage relay module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0463\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5097S-107\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5097-107 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 NC relay contacts are available, connected in parallel and then in series. High process availability is ensured by an SIL 3 safety function for both voltage-controlled (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. This model is designed specifically for high functional safety at input voltage. Short-circuit\/open-circuit detection in line and load as well as load voltage monitoring are integrated in both the de-energised and the energised state. The fault in the field is transmitted directly to the PLC DO output and additionally reported by opening the fault output.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Low input voltage\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC DO\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Isolation of input, output and supply\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528038859101,"sku":"D5097S-107","price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0644_R01_cb3fb2ac-d1d0-4e35-aead-91ba7da082e9.png?v=1772119238"},{"product_id":"d5098d","title":"D5098D safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0305\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5098D\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5098 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has normally open (NO) contacts for up to two energised (NE) loads and normally closed (NC) contacts for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528039416157,"sku":"D5098D","price":223.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0369_R00_3c142070-4f8a-429e-91a9-e01cf84668bb.jpg?v=1772119235"},{"product_id":"d5098s","title":"D5098S safety relays SIL3 relay output module for 5 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0305\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5098S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5098 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has normally open (NO) contacts for up to two energised (NE) loads and normally closed (NC) contacts for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested and prevents contact and LED flickering.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528040071517,"sku":"D5098S","price":141.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0368_R00_6aedfaca-46b0-46b5-a7d8-fe5cf53c7d9a.jpg?v=1772119236"},{"product_id":"d5099d-108","title":"D5099D-108 safety relay output module for 5 A loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0538\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099D-108\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5099-108 is a relay module with up to two SPDT (single pole double throw) contacts isolated from the input. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Both NC and NO contacts available\n\u003cbr\u003e• Low drive current (\u0026lt; 10 mA)\u003cbr\u003e\u003cbr\u003e• 2 N. \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528040825181,"sku":"D5099D-108","price":158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0645_R01_c02c8b3e-b333-4549-ac82-365518ac1d31.png?v=1772119243"},{"product_id":"d5099s","title":"D5099S safety relay output module for 5 A loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0394\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5099 is a relay module with one SPDT (single pole double throw) contact isolated from the input. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Both NC and NO contacts available\n\u003cbr\u003e• Low drive current (\u0026lt; 10 mA)\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528041742685,"sku":"D5099S","price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0927_R01_86c59cba-e1ff-4c51-92de-08e474dd1fc1.png?v=1772119245"},{"product_id":"d5099s-108","title":"D5099S-108 safety relay output module for 5 A loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0538\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099S-108\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5099-108 is a relay module with up to two SPDT (single pole double throw) contacts isolated from the input. Compatibility with certain DO cards with pulse testing must be verified.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Both NC and NO contacts available\n\u003cbr\u003e• Low drive current (\u0026lt; 10 mA)\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528042463581,"sku":"D5099S-108","price":105.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0646_R01_2400c510-312d-459f-9777-079902790f6f.png?v=1772119248"},{"product_id":"d5290s","title":"D5290S safety relays SIL3 relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0111\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. High compatibility with various process control systems (DCS\/PLC) is ensured: an internal circuit allows testing with drive pulses and prevents contact and LED flickering. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for NE loads with NE driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 10 A operating current \/ 16 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact provided\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528051835229,"sku":"D5290S","price":160.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0381_R00_04dcfd5c-2c09-4e20-ab57-14d7590e017f.jpg?v=1772119266"},{"product_id":"d5290s-078","title":"D5290S-078 safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0152\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-078\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-078 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. Up to four NO contacts and two NC contacts are available, which can be connected externally for several normally energised (NE) or normally de-energised (ND) loads with single- or double-sided disconnection of the supply lines, as well as for additional loads. High compatibility with various distributed control systems (DCS) and programmable logic controllers (PLCs) is ensured: an internal circuit allows testing with control pulses and prevents flickering of contacts and LEDs. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Multiple contacts (up to 4 NE or 2 ND loads)\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 isolated SPST transistors \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528052687197,"sku":"D5290S-078","price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0382_R00_e61bc7ae-a60e-4db1-9e49-4279fcd6a8d8.jpg?v=1772119267"},{"product_id":"d5290s-078-sa","title":"D5290S-078\/SA safety relays SIL3 relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0173\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-078\/SA\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-078\/SA relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has up to four normally open contacts (NO) and two normally closed contacts (NC), which can be connected externally for several energised (NE) or de-energised (ND) loads. One or both supply lines can be isolated and additional loads connected. Compatibility with certain DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE driver\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load disconnection on both supply lines possible\n\u003cbr\u003e• Multiple contacts (up to 3 NE loads)\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPST \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528053473629,"sku":"D5290S-078\/SA","price":139.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0383_R00_35d52a68-fc09-4760-b14b-5ed86c0a8ba6.jpg?v=1772119268"},{"product_id":"d5290s-079","title":"D5290S-079 safety relays SIL3 115 Vac relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0153\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-079\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-079 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has up to four normally open contacts (NO) and two normally closed contacts (NC), which can be connected externally for several energised (NE) or de-energised (ND) loads. One or both supply lines can be isolated and additional loads connected. Compatibility with certain DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE driver\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load disconnection on both supply lines possible\n\u003cbr\u003e• Multiple contacts (up to 4 NE or 2 ND loads)\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• 115 V AC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528054260061,"sku":"D5290S-079","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0384_R00_aad0cc3c-62a3-4e8e-ad92-1739d50827e3.jpg?v=1772119269"},{"product_id":"d5290s-080","title":"D5290S-080 safety relays SIL3 115 V AC relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0151\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-080\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-080 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• 115 V AC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528054423901,"sku":"D5290S-080","price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0385_R00_0fab0c7c-10f7-4e1e-918c-155c2c97a686.jpg?v=1772119270"},{"product_id":"d5290s-084","title":"D5290S-084 safety relays SIL3 110 Vdc relay output module for 5 A NE\/ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0170\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-084\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-084 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has up to four normally open contacts (NO) and two normally closed contacts (NC), which can be connected externally for several energised (NE) or de-energised (ND) loads. One or both supply lines can be isolated and additional loads connected. Compatibility with certain DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE driver\n\u003cbr\u003e• Up to 5 A operating current \/ 8 A inrush current\n\u003cbr\u003e• Load disconnection on both supply lines possible\n\u003cbr\u003e• Multiple contacts (up to 4 NE or 2 ND loads)\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 110 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528055767389,"sku":"D5290S-084","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0386_R00_792d2f60-117e-40d1-b68d-f3d22d989f4d.jpg?v=1772119270"},{"product_id":"d5290s-091","title":"D5290S-091 safety relays SIL3 230 V AC relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0294\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-091\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-091 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (NE) loads, two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 230 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 2 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528056455517,"sku":"D5290S-091","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0391_R00_60c48012-3cdc-4b86-8aad-218ed2a68d3d.jpg?v=1772119271"},{"product_id":"d5290s-092","title":"D5290S-092 safety relays SIL3 48 Vdc relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0372\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-092\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290-092 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 48 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528057438557,"sku":"D5290S-092","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0928_R01_900b6072-e917-4dc0-9b17-114cc7aceb6c.png?v=1772119279"},{"product_id":"d5290s-sa","title":"D5290S\/SA safety relays SIL3 relay output module for 10 A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0150\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S\/SA\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5290\/SA relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For energised loads (NE), two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. Compatibility with certain double-connector cards (DO) with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\n\n\nLoad isolation possible on both supply lines\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528057864541,"sku":"D5290S\/SA","price":117.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0395_R00_1321d60b-3654-43e1-acab-b5257e83e012.jpg?v=1772119278"},{"product_id":"d5291s","title":"D5291S safety relays SIL3 relay output module for 10 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0112\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5291S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5291 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, one normally open (NO) and one normally closed (NC) contact are available, optionally with energised or de-energised coil. A service contact is also provided. Thanks to the high compatibility with various process control systems (DCS\/PLC), drive pulse testing is possible, preventing contact and LED flickering. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 rating for ND loads with ND\/NE driver\n\u003cbr\u003e• Installation in Zone 2 \/ Div. 2\n\u003cbr\u003e• Up to 10 A operating current \/ 16 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528058388829,"sku":"D5291S","price":160.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0396_R00_c5a7afac-d8b2-44eb-9148-ecc19a8ad9c8.jpg?v=1772119279"},{"product_id":"d5291s-097","title":"D5291S-097 safety relays SIL3 48 Vdc relay output module for 10 A ND loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0367\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5291S-097\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5291-097 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (ND) loads, it has one normally open (NO) and one normally closed (NC) contact with de-energised coil, plus a service contact. Compatibility with specific DO cards with pulse testing must be verified. This relay module is not suitable for low-current applications (e.g. system-to-system signalling, driving LEDs).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for ND loads with NE driver\n\n\nUp to 10 A operating current \/ 16 A inrush current\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 48 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 10 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• Volt-free SPDT relay \u003cbr\u003e• SIL3 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528058487133,"sku":"D5291S-097","price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0868_R01_3b5eb461-72b9-46a8-9368-27fa21406837.png?v=1772119285"},{"product_id":"d5293s","title":"D5293S Safety relay SIL3 Relay output module for 5 A NE loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0122\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5293S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5293 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. For de-energised (NE) loads, two normally open contacts (NO) are available to isolate the load on both supply lines, plus a normally closed contact (NC) for maintenance purposes. The load can be isolated from the supply in both polarities. High compatibility with various distributed control systems (DCS) and programmable logic controllers (PLC) is ensured: an internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit and open-circuit detection as well as load voltage monitoring are possible both when idle and in operation. Faults in the field are transmitted directly to the PLC output (DO) and additionally reported by opening the fault output. Diagnostic parameters are programmable and can be monitored and configured via Modbus.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE loads with NE driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for fault outputs\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring at the PLC output\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ drive to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 1+1 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528059076957,"sku":"D5293S","price":477.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0390_R00_249441f0-04f5-422c-8c8e-220004863be2.jpg?v=1772119283"},{"product_id":"d5294s","title":"D5294S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0123\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5294S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5294 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. To avoid false trips and increase process availability, 2+2 normally open contacts (NO) are available, connected in parallel and then in series. High process availability is ensured by the SIL 3 safety function for voltage-free (NE) and de-energised (ND) loads (F\u0026amp;G). The load can be isolated from the supply network in both polarities. Wide compatibility with various DCS\/PLCs is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit and open-circuit detection as well as load voltage monitoring are possible with the load both energised and de-energised. The fault in the field is transmitted directly to the PLC output DO and additionally reported by opening the fault output. Diagnostic parameters are programmable and can be monitored and configured via Modbus.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for fault outputs\n\u003cbr\u003e• Installation in Zone 2\/Div. 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Earth fault monitoring\n\u003cbr\u003e• Coil integrity monitoring\n\u003cbr\u003e• Mirroring of field faults to the PLC output\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ apply to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528060453213,"sku":"D5294S","price":639.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0387_R00_2dd473ae-7535-415c-9594-30fd5de80a3a.jpg?v=1772119284"},{"product_id":"d5295s","title":"D5295S Safety relay SIL3 Relay output module for 5 A NE\/ND loads with LFD","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0222\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5295S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe D5295 relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input and output contacts. It has 2+2 NC relay contacts connected in parallel and then in series to avoid false tripping and increase process availability. The SIL 3 safety function ensures high process availability for both voltage-controlled (NE) and voltage-free (ND) loads (F\u0026amp;G). The load can be isolated from the supply in both polarities. Wide compatibility with various DCS\/PLC is ensured: a dedicated internal circuit enables drive pulse testing and prevents flickering of contacts and LEDs. Short-circuit\/open-circuit detection in the line and load as well as monitoring of the load voltage are possible with the load both energised and de-energised. The fault in the field is transmitted directly to the PLC DO output and additionally reported by opening the fault output. Diagnostic parameters are programmable and can be monitored and configured via Modbus.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\n\u003cbr\u003e• SIL 2 \/ SC 3 for fault outputs\n\u003cbr\u003e• Installation in Zone 2\n\u003cbr\u003e• Up to 5 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• High process availability to avoid false trips\n\u003cbr\u003e• Modbus RTU RS\u003cbr\u003e•485 for monitoring and configuration\n\u003cbr\u003e• Service contact available\n\u003cbr\u003e• Input\/output\/supply isolation\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection on line and load\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Earth fault monitoring\n\u003cbr\u003e• Coil integrity monitoring\n\u003cbr\u003e• Mirroring of field faults to the PLC output\u003cbr\u003e\u003cbr\u003e• 1 N \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ de-energise to trip \u003cbr\u003e• 5 A \u003cbr\u003e• 250 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free 2+2 SPST relay \u003cbr\u003e• SIL2 \u003cbr\u003e• D5000","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528061272413,"sku":"D5295S","price":639.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG0388_R00_d42a8119-cbab-4c93-83e5-093bd61c9750.jpg?v=1772119285"},{"product_id":"x1-nis-rlo-em-01-s","title":"X1-NIS-RLO\/EM-01-S safety relays SIL3 electromagnetic relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-01-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/EM-01 electromagnetic relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528236089693,"sku":"X1-NIS-RLO\/EM-01-S","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_08b2e89c-a2ff-489c-88aa-34c60aadc62b.jpg?v=1793959382"},{"product_id":"x1-nis-rlo-em-02-s","title":"X1-NIS-RLO\/EM-02-S safety relays SIL2 electromagnetic relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-02-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/EM-02 electromagnetic relay module is suitable for switching safety-related circuits up to SIL 2 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Two-port isolation, input\/output\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL2 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528236712285,"sku":"X1-NIS-RLO\/EM-02-S","price":88.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_ec97aeb6-204b-475a-a56a-0ac043f43ea1.jpg?v=1772119542"},{"product_id":"x1-nis-rlo-em-03-s","title":"X1-NIS-RLO\/EM-03-S safety relays SIL3 electromagnetic relay output module for 2A ND\/F\u0026G loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-03-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/EM-03 electromagnetic relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for normally de-energised (ND) or fire and gas (F\u0026amp;G) loads. Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPDT \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528237203805,"sku":"X1-NIS-RLO\/EM-03-S","price":151.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_e946a869-1818-4c59-9141-f0af3b366dab.jpg?v=1772119543"},{"product_id":"x1-nis-rlo-em-04-s","title":"X1-NIS-RLO\/EM-04-S Safety relay SIL3 Electromagnetic relay output module for 2A NE loads with diagnostic function","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-04-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe electromagnetic relay module X1-NIS-RLO\/EM-04 is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and supplies a safety normally open contact (NO) for energised (NE) loads. Wide compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit enables testing of drive pulses, prevents flickering of contacts and LEDs and at the same time offers an acceptable resistance for the DO card. Short-circuit and open-circuit detection for lines and loads with programmable limit values as well as load voltage monitoring are possible both when idle and in operation. The fault in the field is passed on directly to the DO switch of the PLC by artificially increasing the input impedance without commutating the relay contacts, and added to the cumulative fault report. To simplify maintenance, field devices can be isolated via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load (programmable thresholds)\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Field fault mirroring to the DCS\/PLC DO card\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPST \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528237859165,"sku":"X1-NIS-RLO\/EM-04-S","price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00_0cb80f82-30f7-4a36-bab9-83300f49a202.jpg?v=1772119544"},{"product_id":"x1-nis-rlo-em-05-s","title":"X1-NIS-RLO\/EM-05-S Safety relay SIL3 Electromagnetic relay output module for 2A ND\/F\u0026G loads with diagnostic function","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-05-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe electromagnetic relay module X1-NIS-RLO\/EM-05 is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and supplies a safety normally open contact (NO) for de-energised (ND) or gas and fire protection (F\u0026amp;G) loads. Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. Short-circuit and open-circuit detection for lines and loads with programmable limit values as well as load voltage monitoring are possible both when idle and in operation. The fault in the field is transmitted directly to the DO switch of the PLC by artificially increasing the input impedance without commutating the relay contacts, and added to the cumulative fault report. To simplify maintenance, field devices can be isolated via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse testing\n\u003cbr\u003e• Short-circuit\/open-circuit detection for line and load (programmable thresholds)\n\u003cbr\u003e• Load voltage monitoring\n\u003cbr\u003e• Fault mirroring to the DCS\/PLC DO card\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 110 V DC \u003cbr\u003e• -40...+60 °C \u003cbr\u003e• 1 volt-free SPST \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528238514525,"sku":"X1-NIS-RLO\/EM-05-S","price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1308_R00.jpg?v=1772119545"},{"product_id":"x1-nis-rlo-ss-01-s","title":"X1-NIS-RLO\/SS-01-S safety relays SIL3 solid-state relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-01-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/SS-01 solid-state relay module is suitable for switching safety-related circuits up to SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Load isolation possible on both supply lines\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528239137117,"sku":"X1-NIS-RLO\/SS-01-S","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00_07fa3f88-7192-4a0f-b031-b80a3fd155f2.jpg?v=1793959382"},{"product_id":"x1-nis-rlo-ss-02-s","title":"X1-NIS-RLO\/SS-02-S safety relays SIL2 solid-state relay output module for 2A NE loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-02-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/SS-02 solid-state relay module is suitable for switching safety-related circuits up to SIL 2 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for energised (NE) loads. Broad compatibility with various DCS\/PLC systems is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 2 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• NE \/ energise to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL2 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528239759709,"sku":"X1-NIS-RLO\/SS-02-S","price":88.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00_d94fb917-2580-4765-bb41-199d98bb209d.jpg?v=1772119546"},{"product_id":"x1-nis-rlo-ss-03-s","title":"X1-NIS-RLO\/SS-03-S safety relays SIL3 solid-state relay output module for 2A ND\/F\u0026G loads","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-03-S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe X1-NIS-RLO\/SS-03 solid-state relay module is suitable for switching safety-related circuits up to safety level SIL 3 for high-risk industries. It provides galvanic isolation between input coils and output contacts and provides a safety normally open contact (NO) for normally de-energised (ND) or fire and gas systems (F\u0026amp;G). Broad compatibility with various process control systems (DCS\/PLC) is ensured: a dedicated internal circuit allows drive pulses to be tested, prevents contact and LED flickering and at the same time provides an acceptable resistance to the DO card. To simplify maintenance work, field devices can be disconnected via a two-position insertion\/removal mechanism. A special termination board is required for this product.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL 3 \/ SC 3\n\u003cbr\u003e• Installation in Zone 2 \/ Division 2\n\u003cbr\u003e• Loop isolation to simplify maintenance work\n\u003cbr\u003e• Up to 2 A operating current \/ 6 A inrush current\n\u003cbr\u003e• Compatible with DCS\/PLC pulse tests\n\u003cbr\u003e• Triple port isolation: input\/output\/supply\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Loop interruption possible \u003cbr\u003e• 24 V DC \u003cbr\u003e• ND \/ apply to trip \u003cbr\u003e• 2 A \u003cbr\u003e• 60 V DC \u003cbr\u003e• -40...+70 °C \u003cbr\u003e• Volt-free SPST SS relays \u003cbr\u003e• SIL3 \u003cbr\u003e• X1","brand":"GMI","offers":[{"title":"Default Title","offer_id":63528240447837,"sku":"X1-NIS-RLO\/SS-03-S","price":151.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1309_R00.jpg?v=1772119547"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/collections\/IMG0363_R01_4ee36052-1e19-476f-bb3d-9311064c3944.png?v=1794561665","url":"https:\/\/www.iam24.de\/en\/collections\/sicherheitsrelais.oembed","provider":"IAM24","version":"1.0","type":"link"}