D1044S intrinsically safe isolators SIL 2 - SIL 3 digital relay output, loop/bus-powered, DIN rail
D1044S intrinsically safe isolators SIL 2 - SIL 3 digital relay output, loop/bus-powered, DIN rail
284,41 €incl. 19% VAT (Germany), plus shipping239,00 € net
/
Für weiterführende Fragen oder eine individuelle Beratung stehe ich – Kian Müller, Geschäftsführer der IAM – Ihnen gerne persönlich zur Verfügung.
In kaufmännischen und vertrieblichen Anliegen berate ich Sie umfassend und unterstütze Sie bei der Auswahl der passenden Lösung. Kontaktieren Sie mich gerne telefonisch, um gemeinsam zu prüfen, wie unsere GMI-Produkte Ihr Unternehmen optimal unterstützen können. Ich freue mich auf den Austausch.
The single- and dual-channel DIN rail digital relay outputs D1044S and D1044D enable devices in hazardous areas to be controlled via contacts, logic levels or control signals in the safe area. They provide galvanic isolation of the three connections (input/output/supply). The outputs are galvanically isolated, the inputs depolarised, to simplify wiring. Typical applications are switching circuits in hazardous areas, changing polarities and signal tones, calibrating strain gauges, resetting field devices and testing fire detectors. Each input channel can either be isolated from the supply network (bus operation) or connected externally (by wiring) to the supply network (loop operation, in which the safety PLC powers the module and its input channel directly). Each output channel has an SPDT relay with two contacts, which are defined as normally open (NO) and normally closed (NC) in the de-energised state. For each channel in normal operation (NE), the output relay is energised, so that the normally open contact (NO) is closed (useful for NE loads or circuits in hazardous areas) and the normally closed contact (NC) is open (useful for ND loads or circuits in hazardous areas). The safe state is reached when the channel and the output relay are de-energised, so that the normally open contact is open (for switching off loads or circuits in hazardous areas) and the normally closed contact is closed (for switching on loads or circuits in hazardous areas).
• SIL2 / SIL3 / SC3
• Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2
• Voltage, contact and logic level input
• Two SPDT relay output signals
• 1 N.
• Isolated input
• -20...+60 °C
• SIL2
• D1000
• 24 V DC
Service that moves professionals forward
We know the requirements of the workshop, the plant and production.
That is why you get more from us than product information: precise sizing, standards know-how and the right accessories from a single source.
FAQ
Is matching accessories available?
You can see matching mounting, climate control or wiring components above in the “Extensions & accessories” section.
How can I reach support?
Telephone: +49 (0) 151 100 25 806 (Mon. - Fri. 09:00 - 18:00)
Email: support@iam24.de