{"product_id":"d1044s","title":"D1044S intrinsically safe isolators SIL 2 - SIL 3 digital relay output, loop\/bus-powered, DIN rail","description":"\u003cdiv style=\"display:flex; gap:10px; flex-wrap:wrap; margin-bottom:20px;\"\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0080\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e📄 Data sheet (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1044S\" target=\"_blank\" rel=\"noopener\" style=\"background-color:#003366;color:#fff;padding:12px 20px;text-decoration:none;border-radius:5px;font-weight:bold;display:inline-block;\"\u003e🏢 Official product page\u003c\/a\u003e\n\u003c\/div\u003e\u003cbr\u003eThe single- and dual-channel DIN rail digital relay outputs D1044S and D1044D enable devices in hazardous areas to be controlled via contacts, logic levels or control signals in the safe area. They provide galvanic isolation of the three connections (input\/output\/supply). The outputs are galvanically isolated, the inputs depolarised, to simplify wiring. Typical applications are switching circuits in hazardous areas, changing polarities and signal tones, calibrating strain gauges, resetting field devices and testing fire detectors. Each input channel can either be isolated from the supply network (bus operation) or connected externally (by wiring) to the supply network (loop operation, in which the safety PLC powers the module and its input channel directly). Each output channel has an SPDT relay with two contacts, which are defined as normally open (NO) and normally closed (NC) in the de-energised state. For each channel in normal operation (NE), the output relay is energised, so that the normally open contact (NO) is closed (useful for NE loads or circuits in hazardous areas) and the normally closed contact (NC) is open (useful for ND loads or circuits in hazardous areas). The safe state is reached when the channel and the output relay are de-energised, so that the normally open contact is open (for switching off loads or circuits in hazardous areas) and the normally closed contact is closed (for switching on loads or circuits in hazardous areas).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e• SIL2 \/ SIL3 \/ SC3\n\u003cbr\u003e• Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2\n\u003cbr\u003e• Voltage, contact and logic level input\n\n\n\u003cbr\u003e• Two SPDT relay output signals\u003cbr\u003e\u003cbr\u003e• 1 N. \u003cbr\u003e• Isolated input \u003cbr\u003e• -20...+60 °C \u003cbr\u003e• SIL2 \u003cbr\u003e• D1000 \u003cbr\u003e• 24 V DC","brand":"GMI","offers":[{"title":"Default Title","offer_id":63527961002333,"sku":"D1044S","price":239.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/IMG1160_R00_c48345cd-c9fd-43ea-aa89-68a7352f0246.jpg?v=1772119062","url":"https:\/\/www.iam24.de\/en\/products\/d1044s","provider":"IAM24","version":"1.0","type":"link"}