{"product_id":"dold-ba9053-612-ac2-20ma-ac-dc24-80v-0064011","title":"DOLD BA9053\/612 AC2-20mA AC\/DC24-80V current relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0064011\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e BA9053\/612 AC2-20mA AC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e BA 9053 – current relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0064011\u003c\/strong\u003e (type BA9053\/612 AC2-20mA AC\/DC24-80V) belongs to the “BA 9053” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe BA 9053 current relay from the VARIMETER series monitors 1-phase DC or AC networks \u003cstrong\u003e(each with 1 measuring range in AC and DC)\u003c\/strong\u003e. The device is set simply and user-friendly via rotary switches on the front of the device. Early detection and preventive maintenance prevent failures of electrical systems and thus guarantee greater operational and system safety.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePreventive maintenance\u003c\/li\u003e\n\u003cli\u003eFor higher productivity\u003c\/li\u003e\n\u003cli\u003eFaster fault localisation\u003c\/li\u003e\n\u003cli\u003ePrecise and reliable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to IEC\/EN 60255-1, IEC\/EN 60947-1\u003c\/li\u003e\n\u003cli\u003eFor monitoring DC and AC currents\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from 2 mA to 25 A\u003c\/li\u003e\n\u003cli\u003eOptionally with 3 measuring ranges 0.1 to 25 A\u003c\/li\u003e\n\u003cli\u003eHigh overload capacity\u003c\/li\u003e\n\u003cli\u003eMeasuring frequency up to 5 kHz\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eAuxiliary voltage AC and AC\/DC\u003c\/li\u003e\n\u003cli\u003eOptionally with start-up bypass\u003c\/li\u003e\n\u003cli\u003eWith switching delay, optionally up to 100 s\u003c\/li\u003e\n\u003cli\u003eOptionally with safe isolation to IEC\/EN 61140 (on request)\u003c\/li\u003e\n\u003cli\u003eOptionally with latching behaviour\u003c\/li\u003e\n\u003cli\u003eOptionally possible with fixed settings\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStart-up bridging\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC 2 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUndercurrent relay. Closed-circuit principle. Switching delay at hysteresis value. With latching behaviour, fault acknowledgement by interrupting the auxiliary voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “BA 9053” product family comprises 382 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up bypass:\u003c\/strong\u003e None; 1 - 100 s; 1 - 20 s; 1 - 60 s; 1 - 30 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 230 V; AC 110 V; AC 240 V; AC\/DC 24 - 80 V; AC\/DC 80 - 230 V; AC 400 V; DC 12 V; AC\/DC 80 - 250 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e AC 2 - 20 mA; AC 20 - 200 mA; AC 30 - 300 mA; AC 50 - 500 mA; AC 0.1 - 1 A; AC 0.5 - 5 A; AC 1 - 10 A; AC 1.5 - 15 A and others (24 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching delay:\u003c\/strong\u003e 0 - 20 s; 0 - 60 s; 0 - 30 s; 0 - 100 s; 0 - 1 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and marks:\u003c\/strong\u003e UKCA, CCC; UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0064011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBA9053\/612 AC2-20mA AC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about BA9053\/612 AC2-20mA AC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for BA9053\/612 AC2-20mA AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0064011 (BA9053\/612 AC2-20mA AC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is BA9053\/612 AC2-20mA AC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eBA9053\/612 AC2-20mA AC\/DC24-80V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for BA9053\/612 AC2-20mA AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for BA9053\/612 AC2-20mA AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the BA 9053 product family; the link is under Downloads below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/85\/00\/75\/1746608116\/BA9053_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet BA 9053 (PDF, 346.55 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/c4\/06\/74\/1780410218\/BA9053.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro BA 9053 (ZIP, 10.16 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407604683101,"sku":"0064011","price":258.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-BA9053.jpg?v=1793919547","url":"https:\/\/www.iam24.de\/en\/products\/dold-ba9053-612-ac2-20ma-ac-dc24-80v-0064011","provider":"IAM24","version":"1.0","type":"link"}