{"product_id":"dold-il9271-11-500-ac-dc24v-0-1-50a-0059915","title":"DOLD IL9271.11\/500 AC\/DC24V 0.1-50A undercurrent relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0059915\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e IL9271.11\/500 AC\/DC24V 0.1-50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e IL 9271 – undercurrent relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0059915\u003c\/strong\u003e (type IL9271.11\/500 AC\/DC24V 0.1-50A) belongs to the “IL 9271” product family (monitoring technology – measuring relays for current monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eUndercurrent monitoring in three-phase and AC networks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eIP 9271, SP 9271, SP 9271CT: 3-phase IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: 1-phase\u003c\/li\u003e\n\u003cli\u003eMeasuring ranges from AC 0.1 ... 100 A\u003c\/li\u003e\n\u003cli\u003eIK 9271, SK 9271: IL 9271, SL 9271: IP 9271, SP 9271: With 1 measuring range, 2 changeover contact With 4 measuring ranges adjustable via rotary switch, 1 changeover contact With 5 measuring ranges adjustable via rotary switch, 1 changeover contact With 4 measuring ranges programmable via jumpers, 2 changeover contact\u003c\/li\u003e\n\u003cli\u003eAdjustable response value\u003c\/li\u003e\n\u003cli\u003eFixed hysteresis\u003c\/li\u003e\n\u003cli\u003eAdjustable switching delay\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eOptional open-circuit principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eLED indicators\u003c\/li\u003e\n\u003cli\u003eWith auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit and measuring circuit galvanically isolated\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs:\u003cul\u003e\n\u003cli\u003eI design, e.g. IK _ _ _ _, with 61 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43880\u003c\/li\u003e\n\u003cli\u003eS design, e.g. SK _ _ _ _, with 100 mm depth and terminals at the top for control cabinets with mounting plate and cable duct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIK 9271, SK 9271: 17.5 mm width IL 9271, SL 9271, SL 9271CT: 35 mm width IP 9271, SP 9271, SP 9271CT: 70 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSwitching delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.1 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1-phase current relay. Closed-circuit principle. 5 measuring ranges adjustable via rotary switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003e1- \/ 3-phase\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInstallation distribution board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “IL 9271” product family comprises 9 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 24 V; AC 220 - 240 V; AC\/DC 42 - 48 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contacts; 1 changeover contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e 0.1 - 15 A; 0.1 - 50 A; 10 mA - 1.5 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0059915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIL9271.11\/500 AC\/DC24V 0.1-50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about IL9271.11\/500 AC\/DC24V 0.1-50A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for IL9271.11\/500 AC\/DC24V 0.1-50A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0059915 (IL9271.11\/500 AC\/DC24V 0.1-50A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is IL9271.11\/500 AC\/DC24V 0.1-50A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIL9271.11\/500 AC\/DC24V 0.1-50A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for IL9271.11\/500 AC\/DC24V 0.1-50A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/2a\/4c\/e1\/1746608191\/IK9271_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9271, IL 9271, IP 9271, SK 9271, SL 9271, SP 9271 (PDF, 1.27 MB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404061479261,"sku":"0059915","price":199.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-IL9271.jpg?v=1793922086","url":"https:\/\/www.iam24.de\/en\/products\/dold-il9271-11-500-ac-dc24v-0-1-50a-0059915","provider":"IAM24","version":"1.0","type":"link"}