{"product_id":"dold-mk5880n-38-200-dc24v-0054048","title":"DOLD MK5880N.38\/200 DC24V insulation monitor","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0054048\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e MK5880N.38\/200 DC24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e MK 5880N – insulation monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0054048\u003c\/strong\u003e (type MK5880N.38\/200 DC24V) belongs to the “MK 5880N” product family (monitoring technology – insulation monitors).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe MK 5880N and MH 5880 insulation monitors from the VARIMETER IMD family are a standards-compliant solution for insulation monitoring of purely three-phase and AC IT systems. The response values are set simply and user-friendly via rotary switches on the front of the device. The MH 5880 also has a galvanically isolated analogue output and a 11-step LED bar display to show the current insulation value.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 61557-8\u003c\/li\u003e\n\u003cli\u003eFor pure three-phase and AC networks with 0 ... 500 V and 10 ... 1000 Hz\u003c\/li\u003e\n\u003cli\u003eMonitoring even when the network is de-energised\u003c\/li\u003e\n\u003cli\u003eAdjustable alarm value for earth fault RAL of 5 ... 100 kΩ\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation of measuring circuit, auxiliary voltage and output contacts\u003c\/li\u003e\n\u003cli\u003eProgrammable for latching or hysteresis behaviour\u003c\/li\u003e\n\u003cli\u003eWith reset and test buttons\u003c\/li\u003e\n\u003cli\u003eAdditional external reset and test buttons can be connected\u003c\/li\u003e\n\u003cli\u003eLED indicators for operational readiness and insulation fault\u003c\/li\u003e\n\u003cli\u003e2 changeover contacts\u003c\/li\u003e\n\u003cli\u003eMK 5880N\/200: With additional pre-warning value\u003cul\u003e\n\u003cli\u003eAdjustable pre-warning value 10 kΩ ... 5 MΩ\u003c\/li\u003e\n\u003cli\u003e1 output relays each for alarm and pre-warning value\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMH 5880\/500: As MK 5880N\/200, but with galvanically isolated analogue output and 11-step LED bar display for the current insulation value\u003c\/li\u003e\n\u003cli\u003eConductor connection: also 2 x 1.5 mm2 stranded wire with ferrule and plastic collar, or 2 x 2.5 mm2 solid DIN 46228-1\/-2\/-3\/-4\u003c\/li\u003e\n\u003cli\u003eOptionally also with pluggable connection blocks for fast device replacement, optional\u003cul\u003e\n\u003cli\u003eWith screw terminals\u003c\/li\u003e\n\u003cli\u003eOr with spring-loaded terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMK 5880N: 22.5 mm width MH 5880: 45 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAlarm value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 - 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTerminal type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFixed screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePre-warning value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10 kOhm - 5 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 output relays (changeover contacts) each for alarm and pre-warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 - 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIndicator for earth fault\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eIMD type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eAt IAM24, the “MK 5880N” product family comprises 14 DOLD articles. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC 220 - 240 V 50 - 400 Hz; AC 380 - 415 V 50 - 400 Hz; DC 24 V; AC 24 V 50 - 400 Hz; DC 12 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal type:\u003c\/strong\u003e Fixed screw terminal; plug-in spring-loaded terminal; plug-in screw terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact configuration:\u003c\/strong\u003e 2 changeover contact(s); 2 x 1 changeover contact(s)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-warning value:\u003c\/strong\u003e None; 10 kOhm - 5 MOhm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0054048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMK5880N.38\/200 DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about MK5880N.38\/200 DC24V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for MK5880N.38\/200 DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0054048 (MK5880N.38\/200 DC24V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is MK5880N.38\/200 DC24V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eMK5880N.38\/200 DC24V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for MK5880N.38\/200 DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there an EPLAN macro for MK5880N.38\/200 DC24V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, DOLD provides an EPLAN macro for the MK 5880N product family; the link can be found below under downloads.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/60\/91\/82\/1746608149\/MK5880N_de.pdf?ts=1781589858\" target=\"_blank\" rel=\"noopener\"\u003eData sheet MK 5880N, MH 5880 (PDF, 467.87 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/56\/a4\/e5\/1780410194\/MK5880N.zip?ts=1784806128\" target=\"_blank\" rel=\"noopener\"\u003eEPLAN macro MK 5880N (ZIP, 171.97 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66403093152093,"sku":"0054048","price":201.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-MK5880N_200.jpg?v=1793922129","url":"https:\/\/www.iam24.de\/en\/products\/dold-mk5880n-38-200-dc24v-0054048","provider":"IAM24","version":"1.0","type":"link"}