{"product_id":"dold-rr5886-ac-dc24-80v-0068302","title":"DOLD RR5886 AC\/DC24-80V test current generator","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0068302\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RR5886 AC\/DC24-80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e RR 5886 – test current generator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0068302\u003c\/strong\u003e (type RR5886 AC\/DC24-80V) belongs to the “RR 5886” product family (monitoring technology – insulation fault locating equipment).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe RR 5886 test current generator, in conjunction with the RR 5887 insulation fault locator, monitors and locates insulation faults in complex insulated AC\/DC networks (IT systems). The external current transformers operate independently of one another. They can be easily connected to the measuring channels of the RR 5887 insulation fault locator and are calibrated by it. By connecting several insulation fault locators via a RS-485 bus connection, the number of measuring channels is increased. This allows the search for insulation faults in widely branched networks to be refined. Two different alarm levels enable timely detection of a dangerous insulation condition. Thanks to automatic adjustments and a clear layout of the setting elements, the devices are simple and intuitive to operate. Early detection and localisation of insulation faults allow them to be rectified quickly and in a targeted manner. As a user, you benefit from the operational reliability and high availability of your network.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFast rectification of insulation faults in complex power networks\u003c\/li\u003e\n\u003cli\u003eUniversal auxiliary voltage range\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulation fault location in AC, DC and AC\/DC networks (IT systems) in conjunction with the RR 5887 insulation fault locator to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)\u003c\/li\u003e\n\u003cli\u003eInsulation coordination to IEC 60664-1\u003c\/li\u003e\n\u003cli\u003eExternal control via insulation monitor possible\u003c\/li\u003e\n\u003cli\u003ePositive and negative test current for monitoring DC networks and networks with simultaneous AC and DC components\u003c\/li\u003e\n\u003cli\u003eRS-485 bus connection for synchronising the test current evaluation and optionally for Modbus RTU fieldbus connection\u003c\/li\u003e\n\u003cli\u003eModbus RTU interface for controlling insulation fault location and reading out insulation fault currents\u003c\/li\u003e\n\u003cli\u003eButton for manual test current output\u003c\/li\u003e\n\u003cli\u003eTerminal connection for automatic test current output\u003c\/li\u003e\n\u003cli\u003eStatus output of insulation fault location via external switching output\u003c\/li\u003e\n\u003cli\u003e105 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAC\/DC 24 - 80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFor industrial plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating mode\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMaster \/ Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “RR 5886” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e AC\/DC 85 - 230 V; AC\/DC 24 - 80 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariant:\u003c\/strong\u003e For medically used areas; For industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0068302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eRR5886 AC\/DC24-80V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about RR5886 AC\/DC24-80V\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for RR5886 AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0068302 (RR5886 AC\/DC24-80V) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is RR5886 AC\/DC24-80V sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eRR5886 AC\/DC24-80V is sold individually; the stated price applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for RR5886 AC\/DC24-80V?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/9f\/09\/ec\/1746608089\/RR5886_de.pdf?ts=1781589861\" target=\"_blank\" rel=\"noopener\"\u003eData sheet RR 5886 (PDF, 248.83 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/45\/80\/64\/1746608166\/Flyer_Isolationsfehlersuchsystem_RR5886_RR5887_F86.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eFlyer: insulation fault location system with Modbus RTU (PDF, 520.24 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/6f\/6d\/90\/1746608116\/Anwenderhandbuch_MODBUS.pdf?ts=1781589863\" target=\"_blank\" rel=\"noopener\"\u003eUser manual Modbus RTU (PDF, 349.2 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66407724286301,"sku":"0068302","price":860.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-RR5886.jpg?v=1793922664","url":"https:\/\/www.iam24.de\/en\/products\/dold-rr5886-ac-dc24-80v-0068302","provider":"IAM24","version":"1.0","type":"link"}