{"product_id":"dold-sl9065-11ct-100-3ac400v-5-100a-0059410","title":"DOLD SL9065.11CT\/100 3AC400V 5-100A underload monitor (cos phi monitor)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0059410\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SL9065.11CT\/100 3AC400V 5-100A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e SL 9065CT – underload monitor (cos phi monitor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0059410\u003c\/strong\u003e (type SL9065.11CT\/100 3AC400V 5-100A) belongs to the “SL 9065CT” product family (monitoring technology – measuring relays for load monitoring).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe IK\/SK\/SL 9065 underload monitor monitors the phase shift between current and voltage. Since the phase shift angle changes with the load on the motor, this measuring method is suitable for monitoring asynchronous motors for underload and no-load running, regardless of frame size. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational reliability and high availability of your system.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAccording to EN 60255-1\u003c\/li\u003e\n\u003cli\u003eDetection of underload (cos ϕ)\u003c\/li\u003e\n\u003cli\u003eWithout auxiliary voltage\u003c\/li\u003e\n\u003cli\u003eFor currents up to 8 A; motors up to approx. 5 A nominal current can be connected directly\u003c\/li\u003e\n\u003cli\u003eExternal current transformer can be connected for higher currents\u003c\/li\u003e\n\u003cli\u003eSL 9065CT with integrated feed-through transformer for currents up to 100 A\u003c\/li\u003e\n\u003cli\u003eAdjustable response value\u003c\/li\u003e\n\u003cli\u003eAutomatic reset (alarm auto reset)\u003c\/li\u003e\n\u003cli\u003eAdjustable response delay up to 100 s\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eFor AC and three-phase loads, e.g. motors\u003c\/li\u003e\n\u003cli\u003eIndependent of direction of rotation\u003c\/li\u003e\n\u003cli\u003e1 changeover contacts\u003c\/li\u003e\n\u003cli\u003eLED indicators for power supply and alarm\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting\u003c\/li\u003e\n\u003cli\u003eDevices optionally in 2 designs: IK 9065, SK 9065: 17.5 mm width IK 9065: 58 mm depth and terminals at the bottom for installation and industrial distribution boards according to DIN 43880 SK 9065, SL 9065CT: 98 mm depth and terminals at the top for control cabinets with mounting plate and cable duct\u003c\/li\u003e\n\u003cli\u003eSL 9065CT: 35 mm width IK\/SK 9065\/100: as IK\/SK 9065 but\u003c\/li\u003e\n\u003cli\u003eProgrammable for\u003cul\u003e\n\u003cli\u003eAutomatic reset or latching behaviour (latched alarm)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit or closed-circuit behaviour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWith RESET button\u003c\/li\u003e\n\u003cli\u003eRemote RESET\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 - 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCurrent range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 - 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWithout auxiliary voltage. Latching behaviour programmable. Closed-circuit \/ open-circuit principle switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0059410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSL9065.11CT\/100 3AC400V 5-100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about SL9065.11CT\/100 3AC400V 5-100A\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for SL9065.11CT\/100 3AC400V 5-100A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0059410 (SL9065.11CT\/100 3AC400V 5-100A) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn what packaging unit is SL9065.11CT\/100 3AC400V 5-100A sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eSL9065.11CT\/100 3AC400V 5-100A is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for SL9065.11CT\/100 3AC400V 5-100A?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/4a\/20\/c6\/1787832311\/IK9065_de.pdf?ts=1793866082\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IK 9065, SK 9065, SL 9065CT (PDF, 453.54 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66404054827357,"sku":"0059410","price":140.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-SL9065.jpg?v=1793922521","url":"https:\/\/www.iam24.de\/en\/products\/dold-sl9065-11ct-100-3ac400v-5-100a-0059410","provider":"IAM24","version":"1.0","type":"link"}