{"product_id":"dold-sl9151-12-2-450k-ohm-dc24v-0-2-20s-0050862","title":"DOLD SL9151.12 2-450K-OHM DC24V 0.2-20S level relay","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e DOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 0050862\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SL9151.12 2-450K-OHM DC24V 0.2-20S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e SL 9151 – level relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery time:\u003c\/strong\u003e 1–2 weeks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe DOLD article \u003cstrong\u003e0050862\u003c\/strong\u003e (type SL9151.12 2-450K-OHM DC24V 0.2-20S) belongs to the “SL 9151” product family (monitoring technology – measuring relays for monitoring physical variables).\u003c\/p\u003e\u003ch2\u003eProduct description from DOLD\u003c\/h2\u003e\u003cp\u003eThe IL 9151 and SL 9051 level relays from the VARIMETER series have 3 electrode connections that can be used for 2-point and 1-point level control. The response value can be set via a rotary switch, as can the response and drop-out delay. The devices can be programmed for open-circuit or closed-circuit principle.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3 electrode connections for 2-point and 1-point level control\u003c\/li\u003e\n\u003cli\u003eWide setting range: 2 ... 450 kΩ\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo IEC\/EN 60255-1\u003c\/li\u003e\n\u003cli\u003eResponse and drop-out delay: separately adjustable for MIN and MAX level\u003c\/li\u003e\n\u003cli\u003eProgrammable for:\u003cul\u003e\n\u003cli\u003e2 separately controlled output relays for MIN and MAX level\u003c\/li\u003e\n\u003cli\u003eJointly controlled output relays in 2-point hysteresis level control\u003c\/li\u003e\n\u003cli\u003eEnergise-to-operate principle (output relay activated in the event of a fault)\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle (output relay not activated in the event of a fault)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFor auxiliary voltages of AC 24 ... 400 V or DC 24 V\u003c\/li\u003e\n\u003cli\u003eLEDs for operational readiness and contact position\u003c\/li\u003e\n\u003cli\u003e2 output relays with 1 changeover contact(s) each\u003c\/li\u003e\n\u003cli\u003eWith safe isolation to IEC\/EN 61140, IEC\/EN 60947-1 (AC 24 ... 240 V)\u003c\/li\u003e\n\u003cli\u003eDevices available in 2 designs: Width: 35 mm width. IL 9151: 59 mm depth and connection terminals at the bottom for installation and industrial distribution boards to DIN 43880. SL 9151: 98 mm depth and connection terminals at the top for control cabinets with mounting plate and cable duct\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse and drop-out delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0.2 - 20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse value\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 - 450 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAuxiliary voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2 x 1 changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eApprovals and markings\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVariant\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eTime delay when the liquid level exceeds or falls below the set level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eResponse delay\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEnclosure design\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eControl cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eClassification\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eLevel monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eVariants of this product family\u003c\/h2\u003e\u003cp\u003eThe “SL 9151” product family comprises 3 DOLD articles at IAM24. According to DOLD, the versions differ in the following features, among others:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e DC 24 V; AC 230 V; AC 127 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCommercial and logistics data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDOLD (E. Dold \u0026amp; Söhne GmbH \u0026amp; Co. KG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArticle number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e0050862\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSL9151.12 2-450K-OHM DC24V 0.2-20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSales unit at IAM24\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePack of 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDelivery time\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1–2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently asked questions about SL9151.12 2-450K-OHM DC24V 0.2-20S\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is the delivery time for SL9151.12 2-450K-OHM DC24V 0.2-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe delivery time for the DOLD article 0050862 (SL9151.12 2-450K-OHM DC24V 0.2-20S) is 1–2 weeks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIn which packaging unit is SL9151.12 2-450K-OHM DC24V 0.2-20S sold?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eSL9151.12 2-450K-OHM DC24V 0.2-20S is sold individually; the price shown applies per piece.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eIs there a data sheet for SL9151.12 2-450K-OHM DC24V 0.2-20S?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the data sheet from DOLD is available to download as a PDF below.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.dold.com\/media\/23\/a3\/39\/1746608138\/IL9151_de.pdf?ts=1788524064\" target=\"_blank\" rel=\"noopener\"\u003eData sheet IL 9151, SL 9151, MK 9151N (PDF, 390.83 KB, DOLD)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"DOLD","offers":[{"title":"Default Title","offer_id":66401670496605,"sku":"0050862","price":152.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/dold-1000-SL9151.jpg?v=1793922085","url":"https:\/\/www.iam24.de\/en\/products\/dold-sl9151-12-2-450k-ohm-dc24v-0-2-20s-0050862","provider":"IAM24","version":"1.0","type":"link"}