{"product_id":"rittal-dk-7979140-pdu-basic","title":"Rittal DK 7979.140 PDU basic, 44x70 mm (WxD), number and type of sockets 36 x C13 \/ 6 x C19, rated current (max.) 16 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.140 (7979140)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,800 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 36 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947566\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.140\u003c\/strong\u003e (PDU basic; number and type of sockets 36 x C13 \/ 6 x C19, rated current (max.) 16 A) is a genuine Rittal article. High-end IT rack power distribution: robust PDU with compact basic power distribution for the IT environment.\u003c\/p\u003e\u003cp\u003eThe Rittal Power Distribution Unit PDU basic is a compact basic power distribution unit for use in IT server and network enclosures. The robust housing is made of anodised extruded aluminium profile and carries permanently mounted output sockets, which, depending on type, are designed as IEC 60320\/C13, IEC 60320\/C19, CEE 7\/3 (Schuko) or BS 1363 (UK). The PDU basic is part of Rittal's high-end IT rack power distribution range.\u003c\/p\u003e\u003cp\u003eThe IEC output sockets C13 and C19 can additionally be protected against accidental unplugging of the plugs with a locking device. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU, and a declaration of conformity is stated as evidence.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Anodised extruded aluminium profile; the sockets are made of plastic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput sockets:\u003c\/strong\u003e Permanently mounted, depending on type IEC 60320\/C13, C19, CEE 7\/3 (Schuko) or BS 1363 (UK).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket covers:\u003c\/strong\u003e Unused sockets can be closed with covers from the accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e Operating temperature 5 °C to 50 °C, storage temperature -20 °C to 70 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlug locking for IEC C14, C20 plugs\u003c\/li\u003e\n\u003cli\u003eIncl. fixing material\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eExtruded aluminium profile, anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePlug locking for IEC C14, C20 plugs\u003cbr\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e36 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU basic art. no.: DK 7979.140\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK).\u003cbr\u003e(exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003esurge protection module (type 3) with arresters\u003cbr\u003ethat can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection.\u003cbr\u003eTechnical specifications PDU basic\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 36\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 12\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 0\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 6\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1495 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT\/TS IT) mounting: frame+\u003cbr\u003eZero-USpace + cable tray, fuse monitoring (32 A)\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level) 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU basic art. no.: DK 7979.140\u003cbr\u003ePDU Basic 16A\/3P CEE 36x C13 \/ 6x C19\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.140\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.140?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePlug locking for IEC C14, C20 plugs, incl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat are the socket covers of the PDU basic used for?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eUnused sockets can be closed with socket covers available as accessories. This rules out unintentional overloading of individual phases and circuits.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.140?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_7716\/7979140_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377858646365,"sku":"7979140","price":306.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979140-pdu-basic.jpg?v=1793628152","url":"https:\/\/www.iam24.de\/en\/products\/rittal-dk-7979140-pdu-basic","provider":"IAM24","version":"1.0","type":"link"}