{"product_id":"rittal-dk-7979237-pdu-metered","title":"Rittal DK 7979.237 PDU metered, 44x70 mm (WxD), number and type of sockets 24 x C13 \/ 6 x C19, 400 V (AC)","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.237 (7979237)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 2,000 mm · enclosure type: VX IT 19\" profile rails: ≥ 2,000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber and type of sockets:\u003c\/strong\u003e 24 x C13 \/ 6 x C19\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 400 V (AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947771\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.237\u003c\/strong\u003e (PDU metered; number and type of sockets 24 x C13 \/ 6 x C19, 400 V (AC)) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with energy metering per phase, i.e. the power demand of an entire IT rack.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU metered is an intelligent power distribution unit for IT racks with energy metering per phase and thus records the power demand of an entire IT rack. The integrated TFT colour display is used for basic configuration and quick access to electrical consumption data. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eRemote access and data transmission via various protocols are possible via Gigabit network interfaces and the integrated web server. The directives stated are the EMC Directive 2014\/30\/EU and the Low Voltage Directive 2014\/35\/EU; the certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring functions:\u003c\/strong\u003e extensive current and power monitoring per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and FTP\/SFTP for updates and file transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring:\u003c\/strong\u003e sensors from the CMC accessories range, for example for temperature, humidity, smoke, leakage and access, can be connected to the CAN sensor interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient conditions:\u003c\/strong\u003e operating temperature 5 °C to 50 °C, humidity 10 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ± 0.5 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003cli\u003eEnergy-saving design, low self-consumption\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, metered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eCompact miniature circuit breakers (16 A - Carling type)\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003ePower LED for voltage indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,740 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e24 x C13 \/ 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e400 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 3~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of RJ45 ports for sensor units, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 2,000 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 2,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e6.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered art. no.: DK 7955.237\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions. Depending on the version\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; a fixed connecting cable with IEC C20 or\u003cbr\u003eCEE plug is fitted, so the PDU is ready for immediate use.\u003cbr\u003eThe PDU Metered features extensive\u003cbr\u003emeasuring functions for current \u0026amp; power monitoring per phase. The integrated TFT colour display can be used to set the basic configuration and to gain quick access to the electrical consumption data. Via two Gigabit network interfaces and the integrated web server, remote access and data transmission via various\u003cbr\u003eprotocols are possible. The consumption parameters can be forwarded to DCIM software via\u003cbr\u003eSNMP, OPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature \/ humidity \/ smoke \/ leakage \/ access as well as VX IT and TS IT handle systems) from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eThe PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU\u003cbr\u003eversions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Metered\u003cbr\u003eInput voltage range (L1-L2-L3\/N\/PE): 400 VAC, 50-60 Hz\u003cbr\u003eInput current: 32A\u003cbr\u003eNumber of phases: 3\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 24\u003cbr\u003eNumber of Type IEC 60320\/C13 slots (per phase\/fuse 1 per phase): 8 \/ 8\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 6\u003cbr\u003eNumber of Type IEC 60320\/C19 slots (per phase\/fuse 2 per phase): 2 \/ 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: 6\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (3L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 5\u003cbr\u003eCable cross-section: 4 mm²\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1740 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase):\u003cbr\u003eVoltage (V), current (A), frequency (Hz)\u003cbr\u003eActive power (kW), active energy (kWh), apparent power (kVA)\u003cbr\u003ePower factor, neutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eNetwork interface: RJ45, integrated web server\u003cbr\u003eSupported protocols:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, XML\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eCAN bus interface: RJ45, connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, NH measuring module, smoke detector, vandalism\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eairflow, EFD, differential pressure, VX IT\/TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP 20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20:\u003cbr\u003e1x (others optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Metered art. no.: DK 7979.237\u003cbr\u003ePDU metered 32A\/3P CEE 24xC13 \/ 6xC19\u003cbr\u003eRittal PDU metered, Model No.: DK 7955.237\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.237\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.237?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eHow can the consumption data of the PDU metered be passed on to DCIM software?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eThe consumption parameters can be forwarded to DCIM software via SNMP, OPC-UA and Modbus\/TCP. A MIB is available for integration into third-party DCIM software.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.237?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979237_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979237_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979237_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860088157,"sku":"7979237","price":903.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979237-pdu-metered.jpg?v=1793628208","url":"https:\/\/www.iam24.de\/en\/products\/rittal-dk-7979237-pdu-metered","provider":"IAM24","version":"1.0","type":"link"}