{"product_id":"rittal-dk-7979303-pdu-switched","title":"Rittal DK 7979.303 PDU switched, 44x144 mm (HxD), rated current (max.) 16 A, WHD: 450x44x144 mm, CEE 7\/3: 4x Schuko","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.303 (7979303)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 800 mm · enclosure type: VX IT 19\" profile rails: ≥ 800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current (max.):\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177947832\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.303\u003c\/strong\u003e (PDU switched; rated current (max.) 16 A, WHD: 450x44x144 mm, CEE 7\/3: 4x Schuko) is a genuine Rittal article. High-end IT rack power distribution: intelligent PDU with measuring function per phase and individually switchable output sockets.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU switched is an intelligent power distribution unit from the high-end IT rack power distribution range with measuring function per phase and individually switchable output sockets. Switching functions are possible per output socket; current and power monitoring is carried out per phase. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eThe integrated TFT display shows performance data and the basic configuration; the display\/controller unit can be rotated by 180° and replaced in the PDU enclosure. The integrated, fully redundant power supply unit is fed from all phases. The certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured values:\u003c\/strong\u003e voltage, current, frequency, active and apparent power, active and apparent energy, power factor (cosPhi) and phase angle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains monitoring:\u003c\/strong\u003e neutral conductor current measurement with unbalanced load detection, fuse monitoring for PDUs with integrated fuse and monitoring of the optionally available surge protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e USB-A, CAN bus (RJ45) for environmental sensors, RS232 (RJ12) and fully redundant Ethernet interface 10\/100\/1000 Mbit\/s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity and access:\u003c\/strong\u003e TLS 1.2, custom certificates, user management including rights management, and LDAP(S), Radius and Active Directory connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e web server (HTTP, HTTPS, SSL), SSH, SNMP v1, v2c and v3, Modbus\/TCP, OPC-UA, and MIB for integration into third-party DCIM software.\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eProgrammable switch-on behaviour after power recovery (on\/off\/last state)\u003c\/li\u003e\n\u003cli\u003eProgrammable switching behaviour (time\/programmable logic)\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power\u003c\/li\u003e\n\u003cli\u003eTotal and cyclic operating hours counter, resettable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eVersion 19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003eMulticolour LEDs (green\/yellow\/red) for signalling the switching states and warning\/alarm limit values per phase or infeed\u003cbr\u003ePower LED for voltage indication\u003cbr\u003eEnergy-saving design, low self-consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eSurge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing\u003cbr\u003eResidual current measurement (Type B) per infeed\/phase\/fuse\u003cbr\u003eMonitoring of the optionally available surge protection\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003cbr\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEmergency supply of the PDU web server via PoE, sequential switch-off of the outputs\u003cbr\u003eSwitching function per output socket\u003cbr\u003eAvoidance of overload peaks: sequential switch-on of the outputs after power recovery\u003cbr\u003eStorage of relay switching states even in the event of a power failure\u003cbr\u003eBistable relays: low current consumption and high switching capacity, also for higher inrush currents up to max. 300 A\u003cbr\u003eGroupings: joint switching of several outputs\u003cbr\u003eMeasurement per phase or infeed\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eHeight: 44 mm\u003cbr\u003eDepth: 144 mm\u003cbr\u003eLength: 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4 x Schuko, type F, CEE 7\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection cable length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 800 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177947832\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Switched art. no.: DK 7979.303\u003c\/strong\u003e\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Robust aluminium housing with permanently mounted output sockets, depending on\u003cbr\u003etype IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eThe PDU Switched features extensive\u003cbr\u003emeasuring functions for current-\u0026lt;(\u0026gt;\u0026amp;\u0026lt;)\u0026gt;power monitoring per phase\u003cbr\u003eSwitching functions are possible per output socket.\u003cbr\u003eVia the integrated TFT colour display, the\u003cbr\u003ebasic configuration can be set and quick access to the electrical consumption data can be gained. Via two Gigabit network interfaces and the integrated web server, remote access and\u003cbr\u003edata transmission via various protocols are possible.\u003cbr\u003eThe consumption parameters can be forwarded to SNMP, OPC-UA\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eModbus\/TCP to a DCIM software. To monitor the environmental parameters, up to 16 sensors (e.g. temperature\/humidity\/\u003cbr\u003esmoke\/leakage\/access) as well as VX IT and\u003cbr\u003eTS IT handle systems from the CMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eTechnical specifications PDU Switched\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003ePhase marking (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): -\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): 4\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): 4\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16A\u003cbr\u003eSwitching function per output socket: yes\u003cbr\u003ePDU input connector plug:\u003cbr\u003eEN 60309 \/ CEE (L+N+PE, 6h)\u003cbr\u003eLength of connecting cable: 3 m\u003cbr\u003eConnecting cable type: H05-VV\u003cbr\u003eNumber of cores: 3\u003cbr\u003eCable cross-section: 2.5 mm²\u003cbr\u003ePDU housing width: 450 mm\u003cbr\u003ePDU housing depth: 144 mm\u003cbr\u003ePDU housing height: 44 mm (1 U)\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per phase or infeed\u003cbr\u003eMeasured values (per phase): voltage (V), current (A)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003efrequency (Hz), active power (kW), active energy (kWh)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eApparent power (kVA), power factor\u003cbr\u003eTHD (voltage and current) for 3-phase\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eCrest factor for 1-phase\u003cbr\u003eNeutral conductor current measurement\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFuse monitoring (at 32 A)\u003cbr\u003eOptional: residual current measurement (RCM)\u003cbr\u003eAC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eController board: rotatable and replaceable during operation\u003cbr\u003eSupported protocols:\u003cbr\u003eIPv4 \/ IPv6, integrated web server\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 and v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c and v3, traps\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u003cbr\u003eOPC-UA, Modbus\/TCP\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory connection: yes\u003cbr\u003eUSB port for firmware update and data logging function: yes\u003cbr\u003eInitial commissioning\/mass configuration:\u003cbr\u003eYes, via predefined CSV file\u003cbr\u003eCAN bus interface: RJ45\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; for connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, airflow, EFD, NH measuring module, smoke detector\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003evandalism, differential pressure\u003cbr\u003eVX IT \/ TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eSerial interface: RS232 (RJ12) for e.g. LTE unit\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSafety directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature: -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity: 10 - 95% RH, non-condensing\u003cbr\u003ePlug locking C14 and C20: 1x\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessories): DK 7955.015 (further optional DK 7979.020)\u003cbr\u003eType: Rittal PDU Switched art. no.: DK 7979.303\u003cbr\u003ePDU switched 16A\/1P CEE 4x earthing-pin\u003cbr\u003eRittal PDU switched Model No.: DK 7979.303\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.303\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.303?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan the output sockets of the PDU switched be switched individually?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes, the PDU switched has individually switchable output sockets; switching functions are possible per output socket. Green, yellow and red LEDs signal the switching states and warning\/alarm limit values per phase or infeed.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.303?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979303_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979303_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979303_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377860415837,"sku":"7979303","price":935.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979303-pdu-switched.jpg?v=1793628208","url":"https:\/\/www.iam24.de\/en\/products\/rittal-dk-7979303-pdu-switched","provider":"IAM24","version":"1.0","type":"link"}