{"product_id":"rittal-dk-7979418-pdu-managed","title":"Rittal DK 7979.418 PDU managed, 44x70 mm (WxD), sockets 18, 2","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAt a glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e DK 7979.418 (7979418)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for:\u003c\/strong\u003e VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19\" profile rails: ≥ 1,800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSockets:\u003c\/strong\u003e 18, 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging unit:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177973503\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eThe \u003cstrong\u003eRittal DK 7979.418\u003c\/strong\u003e (PDU managed; sockets 18, 2) is a genuine Rittal article. High-end IT rack power distribution with energy measurement and monitoring functions for each individual output socket. Input with CEE plug (16 A\/32 A) with C13 and C19 outputs.\u003c\/p\u003e\u003cp\u003eThe Rittal PDU managed is a high-end IT rack power distribution unit with energy measurement and monitoring functions for each individual output socket. The input is designed with a CEE plug (16 A\/32 A), the outputs as C13 and C19. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.\u003c\/p\u003e\u003cp\u003eIn addition to measurement per phase or infeed, measurement is also carried out per output socket; the outputs can be switched individually and grouped. The integrated TFT display shows performance data and the basic configuration. The certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.\u003c\/p\u003e\u003ch2\u003eBenefits and features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching function:\u003c\/strong\u003e switching per output socket, with grouping for joint switching of several outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBistable relays:\u003c\/strong\u003e low current consumption and high switching capacity, also for higher inrush currents up to max. 300 A; the switching states are retained even in the event of a power failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency supply:\u003c\/strong\u003e the PDU web server is powered in an emergency via PoE; the outputs are switched off sequentially.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs and outputs:\u003c\/strong\u003e digital input (volt-free contact) and additional alarm output\/relay output (changeover contact).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces and protocols:\u003c\/strong\u003e fully redundant Ethernet interface 10\/100\/1000 Mbit\/s, USB-A, CAN bus for environmental sensors, as well as SNMP, Modbus\/TCP and OPC-UA.\u003c\/li\u003e\n\u003cli\u003eWith vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools\u003c\/li\u003e\n\u003cli\u003eColour marking of phases and fused circuits (L1=pink, L2=black, L3=white)\u003c\/li\u003e\n\u003cli\u003eTool-free installation kit for VX IT\u003c\/li\u003e\n\u003cli\u003ePDU is self-powered, no external power supply required\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy ±1 % (kWh) to EN 62 053-21\u003c\/li\u003e\n\u003cli\u003eProgrammable switch-on behaviour after power recovery (on\/off\/last state)\u003c\/li\u003e\n\u003cli\u003eProgrammable switching behaviour (time\/programmable logic)\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time clock with battery backup (max. 10 years, battery replaceable)\u003c\/li\u003e\n\u003cli\u003eIntegrated electromagnetic buzzer for acoustic alarm\u003c\/li\u003e\n\u003cli\u003eAdjustable limit values (warning\/alarm) for voltage, current, power, individually adjustable for each output socket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eScope of supply\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIncl. fixing material\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArt. no.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVersion\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003ePDU, managed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnical data\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDisplay\/controller unit in the PDU enclosure rotatable by 180° and replaceable\u003cbr\u003eIntegrated, fully redundant power supply unit, fed from all phases\u003cbr\u003eFault-tolerant PDU power supply, redundant across all phases\u003cbr\u003eVoltage V, current A, frequency Hz\u003cbr\u003eActive power, active energy, apparent power, apparent energy\u003cbr\u003ePower factor (cosPhi) and phase angle\u003cbr\u003eNeutral conductor current measurement\/unbalanced load detection\u003cbr\u003eFuse monitoring for PDUs with integrated fuse\u003cbr\u003eBright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration\u003cbr\u003ePosition sensors for display rotation and correct PDU display on the web page\u003cbr\u003eMulticolour LEDs (green\/yellow\/red) for signalling the switching states and limit values for each individual output socket\u003cbr\u003ePower LED for voltage indication\u003cbr\u003eEnergy-saving design, low self-consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminium profile, black anodised\u003cbr\u003eSockets: plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIncl. fixing material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eCMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors\u003cbr\u003eOther housing colours possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDescription of measuring functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEmergency supply of the PDU web server via PoE, sequential switch-off of the outputs\u003cbr\u003eSwitching function per output socket\u003cbr\u003eAvoidance of overload peaks: sequential switch-on of the outputs after power recovery\u003cbr\u003eStorage of relay switching states even in the event of a power failure\u003cbr\u003eBistable relays: low current consumption and high switching capacity, also for higher inrush currents up to max. 300 A\u003cbr\u003eGroupings: joint switching of several outputs\u003cbr\u003eMeasurement per phase or infeed\u003cbr\u003eAdditional measurement per output socket\u003cbr\u003eHigh-performance CPU (ARM Cortex A8)\u003cbr\u003eDigital input (volt-free contact)\u003cbr\u003eAdditional alarm output\/relay output (changeover contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWidth: 44 mm\u003cbr\u003eDepth: 70 mm\u003cbr\u003eLength: 1,095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNumber of sockets and type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18 x C13 \/ 2 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSocket outlets\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e18\u003cbr\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e230 V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated current (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eFeeds\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eNumber: 1\u003cbr\u003ePhases per feed: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eConnection type (electrical)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eIEC C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUSB 2.0 port (USB-A) for bulk configuration, firmware update \u0026amp; data logging\u003cbr\u003eCAN bus interface (RJ45) for max. 16 environmental sensors\u003cbr\u003eSerial interface RS232 (RJ12) for LTE Unit, scripting, CLI\u003cbr\u003eUse of own certificates\/TLS 1.2\u003cbr\u003eEmail dispatch on alarm (SMTP)\u003cbr\u003eUser management incl. rights management\u003cbr\u003eLDAP(S)\/RADIUS\/Active Directory integration\u003cbr\u003eSyslog server integration (max. 2 servers)\u003cbr\u003eFully redundant Ethernet interface 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eDirectives\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eLow Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eProtocols\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP\u003cbr\u003eTCP\/IP v4 \u0026amp; v6, DHCP, DNS\u003cbr\u003eSNMP v1, v2c \u0026amp; v3, Modbus\/TCP, OPC-UA\u003cbr\u003eMIB for integration into 3rd party DCIM software\u003cbr\u003eFTP\/SFTP (update\/file transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eHumidity (non-condensing)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-20 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSuitable for\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEnclosure type: VX IT enclosure frame: ≥ 1,200 mm\u003cbr\u003eEnclosure type: VX IT 19\" support rails: ≥ 1,800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePackaging unit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eGross weight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eCustoms tariff number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177973503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eSpecification text\u003c\/summary\u003e\u003cp\u003e**Rittal PDU Managed art. no.: DK 7979.418\u003cbr\u003ePDU managed 16A\/1P IEC C20 18xC13 \/ 2xC19**\u003cbr\u003eCompact power distribution for use in IT server and\u003cbr\u003enetwork enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and\u003cbr\u003eTS IT rack by means of special\u003cbr\u003eplug \u0026amp; play fixing supplied. Robust aluminium\u003cbr\u003ehousing with permanently mounted output sockets, depending on type IEC 60320\/C13 or IEC 60320\/C19 as well as\u003cbr\u003eCEE 7\/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13\/C19\u003cbr\u003eoutput sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional\u003cbr\u003eoverloading of individual phases \u0026amp; circuits. The fused circuits or\u003cbr\u003ephases are colour-marked on multi-phase PDU versions.\u003cbr\u003eA connection cable with IEC C20 or CEE plug makes the PDU ready for immediate use.\u003cbr\u003eThe PDU Managed features extensive\u003cbr\u003emeasuring and switching function for current \u0026lt;(\u0026gt;\u0026amp;\u0026lt;)\u0026gt;\u003cbr\u003epower monitoring per output socket.\u003cbr\u003eVia the integrated TFT colour display, the\u003cbr\u003ebasic configuration can be set and quick\u003cbr\u003eaccess to the electrical consumption data can be gained. Via two Gigabit\u003cbr\u003enetwork interfaces and the integrated\u003cbr\u003eweb server, remote access and\u003cbr\u003edata transmission via various protocols are possible.\u003cbr\u003eThe consumption parameters can be forwarded to a DCIM software via SNMP\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eOPC-UA, Modbus\/TCP. To monitor the\u003cbr\u003eenvironmental parameters, up to 16 sensors (e.g. temperature\/ humidity\/ smoke\/ leakage\/ access) as well as VX IT and TS IT handle systems from the\u003cbr\u003eCMC accessories range can be connected to the CAN sensor interface.\u003cbr\u003eOptionally, the PDU can be fitted at the feed with a\u003cbr\u003ecan be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.\u003cbr\u003eWith intelligent PDUs, the status is monitored.\u003cbr\u003eOptionally, all PDU versions, except the\u003cbr\u003ePDU Basic series, are available with an all-current-sensitive residual current measurement (RCM Type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.\u003cbr\u003eTechnical specifications PDU Managed\u003cbr\u003eInput voltage range (L\/N\/PE): 230 VAC, 50-60 Hz\u003cbr\u003eInput current: 16A\u003cbr\u003eNumber of phases: 1\u003cbr\u003eMarking of phases (only 3-phase PDUs: L1, L2, L3):\u003cbr\u003epowerpink, black, white\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (total): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C13 (per phase\/fuse): 18\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (total): 2\u003cbr\u003eNumber of sockets type IEC 60320\/C19 (per phase\/fuse): 2\u003cbr\u003eNumber of sockets type CEE 7\/3 (total): -\u003cbr\u003eNumber of sockets type CEE 7\/3 (per phase\/fuse): -\u003cbr\u003eNumber of circuit breakers: -\u003cbr\u003eHydraulic-magnetic circuit breaker: 16 A\u003cbr\u003eSlots individually switchable: yes\u003cbr\u003ePDU input connector plug: EN 60320 \/ IEC C20\u003cbr\u003ePDU housing width: 44 mm\u003cbr\u003ePDU housing depth: 70 mm\u003cbr\u003ePDU housing height: 1095 mm\u003cbr\u003ePDU material: aluminium, anodised in RAL9005 (black)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; other colours available on request\u003cbr\u003ePDU mounting adaptor (VX IT \/ TS IT) installation:\u003cbr\u003eFrame + Zero-U space + cable tray\u003cbr\u003eMeasuring functions: measurement per output or slot\u003cbr\u003eSwitching function: switching per output socket\u003cbr\u003eMeasured values (per phase): voltage (V), current (A)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003efrequency (Hz), active power (kW), active energy (kWh)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eapparent energy (kVAh), apparent power (kVA)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003ereactive power (var), power factor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eTHD (voltage and current) for 3-phase\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eCrest factor for 1-phase, neutral conductor current measurement\u003cbr\u003eFuse monitoring (at 32 A); optional:\u003cbr\u003eResidual current measurement (RCM): AC + DC (RCM Type B) max. 6 measuring points per PDU possible (input \/ per phase \/ per fuse) 0 mA – 100 mA per RCM\u003cbr\u003eVoltage measuring range: 90V - 255V\u003cbr\u003eVoltage resolution 0.1 V\u003cbr\u003eCurrent measuring range 0 - 16A\/32A\u003cbr\u003eCurrent resolution 0.1 A\u003cbr\u003eMeasuring accuracy typ. ± 1% to IEC\/EN 62 053-21\u003cbr\u003eFreely adjustable limit values (warning\/alarm) for voltage, current, power: yes\u003cbr\u003eOperating hours counter: yes\u003cbr\u003eDisplay: TFT, RGB 128x128 pixels\u003cbr\u003eNetwork interfaces: 2xRJ45, each 10\/100\/1000 Mbit\/s\u003cbr\u003eController board: rotatable and replaceable during operation\u003cbr\u003eSupported protocols: IPv4 \/ IPv6\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; integrated web server, HTTP, HTTPS, SSL, SSH\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eNTP, Telnet, TCP\/IP v4 and v6, DHCP, DNS, NTP\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eSyslog, SNMP v1, v2c and v3, traps\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eOPC-UA, Modbus\/TCP\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eFTP\/SFTP (update \/ file transfer)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eEmail sending (SMTP)\u003cbr\u003eUser management incl. rights management: yes\u003cbr\u003eLDAP(S) \/ Radius connection: yes\u003cbr\u003eUSB port for firmware update \/ data logging function: yes\u003cbr\u003eInitial commissioning\/mass configuration:\u003cbr\u003eYes, via predefined CSV file\u003cbr\u003eCAN bus interface: RJ45, for connection of 16 sensors\u003cbr\u003eCAN sensor types: temperature\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003etemperature\/humidity (combined), infrared access sensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eleakage, airflow, EFD, NH measuring module, smoke detector\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003evandalism, differential pressure\u003cbr\u003eVX IT \/ TS IT handle system\u003cbr\u003ePlug \u0026amp; play driver in Rittal RiZone DCIM software: yes\u003cbr\u003eDigital input: 1\u003cbr\u003eAlarm relay: 48V DC\/2A\u003cbr\u003eAcoustic signal sounder\u003cbr\u003eSerial interface:\u003cbr\u003eRS232 (RJ 12) e.g. for LTE unit 7030.571\u003cbr\u003eConformity: CE\u003cbr\u003eStandards:\u003cbr\u003eSafety: EN 62368\u003cbr\u003eEMC:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eLow Voltage Directive: 2014\/35\/EU\u003cbr\u003eEMC Directive: 2014\/30\/EU\u003cbr\u003eMTBF (at 40°C) 100,000 hours\u003cbr\u003eProtection category: IP20 (EN 60529)\u003cbr\u003eProtection class: Class 1\u003cbr\u003ePollution degree: 2\u003cbr\u003eOvervoltage category: II\u003cbr\u003eEnvironmental properties: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eStorage temperature: -20°C to +70°C\u003cbr\u003eAmbient temperatures +5°C to +50°C\u003cbr\u003eAmbient humidity: 10 - 95% RH, non-condensing\u003cbr\u003eOperating altitude (max. above sea level): 3000 m\u003cbr\u003ePlug locking C14 and C20: 1x (further optional DK 7979.020)\u003cbr\u003eCovers C13 (optional accessory): DK 7955.010\u003cbr\u003eCovers C19 (optional accessory): DK 7955.015\u003cbr\u003eType: Rittal PDU Managed art. no.: DK 7979.418\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eFrequently asked questions about Rittal DK 7979.418\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhat is included in the scope of supply of the Rittal DK 7979.418?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eIncl. fixing material.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eCan overload peaks be avoided when switching on the outputs?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYes. After power recovery, the outputs are switched on sequentially, which avoids overload peaks.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWhich accessories fit the Rittal DK 7979.418?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eYou will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.\u003c\/p\u003e\u003ch2\u003eApprovals and certificates\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-tested security\u003c\/li\u003e\n\u003cli\u003eDeclaration of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads from Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979418_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eInstructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979418_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eQuick start guide\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979418_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAdditional instructions\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377861529949,"sku":"7979418","price":1529.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979418-pdu-managed.jpg?v=1793628208","url":"https:\/\/www.iam24.de\/en\/products\/rittal-dk-7979418-pdu-managed","provider":"IAM24","version":"1.0","type":"link"}