Rittal DK 7979.435 PDU managed, 44x70 mm (WxD), sockets 18 x C 13, 3 x C 19
Rittal DK 7979.435 PDU managed, 44x70 mm (WxD), sockets 18 x C 13, 3 x C 19
1.642,27 €incl. 19% VAT (Germany), plus shipping1.380,06 € net
/
Für weiterführende Fragen oder eine individuelle Beratung stehe ich – Kian Müller, Geschäftsführer der IAM – Ihnen gerne persönlich zur Verfügung.
In kaufmännischen und vertrieblichen Anliegen berate ich Sie umfassend und unterstütze Sie bei der Auswahl der passenden Lösung. Kontaktieren Sie mich gerne telefonisch, um gemeinsam zu prüfen, wie unsere Rittal-Produkte Ihr Unternehmen optimal unterstützen können. Ich freue mich auf den Austausch.
At a glance
- Article number: DK 7979.435 (7979435)
- Suitable for: VX IT enclosure frame: ≥ 1,200 mm · enclosure type: VX IT 19" profile rails: ≥ 1,800 mm
- Sockets: 18 x C 13, 3 x C 19
- Packaging unit: 1 piece
- EAN: 4028177948198
The Rittal DK 7979.435 (PDU managed; sockets 18 x C 13, 3 x C 19) is a genuine Rittal article. High-end IT rack power distribution with energy measurement and monitoring functions for each individual output socket. Input with CEE plug (16 A/32 A) with C13 and C19 outputs.
The Rittal PDU managed is a high-end IT rack power distribution unit with energy measurement and monitoring functions for each individual output socket. The input is designed with a CEE plug (16 A/32 A), the outputs as C13 and C19. The enclosure is made of black anodised aluminium profile; the sockets are made of plastic.
In addition to measurement per phase or infeed, measurement is also carried out per output socket; the outputs can be switched individually and grouped. The integrated TFT display shows performance data and the basic configuration. The certificates stated are Cyber Security Certificate, declaration of conformity and TÜV-tested safety.
Benefits and features
- Switching function: switching per output socket, with grouping for joint switching of several outputs.
- Bistable relays: low current consumption and high switching capacity, also for higher inrush currents up to max. 300 A; the switching states are retained even in the event of a power failure.
- Emergency supply: the PDU web server is powered in an emergency via PoE; the outputs are switched off sequentially.
- Inputs and outputs: digital input (volt-free contact) and additional alarm output/relay output (changeover contact).
- Interfaces and protocols: fully redundant Ethernet interface 10/100/1000 Mbit/s, USB-A, CAN bus for environmental sensors, as well as SNMP, Modbus/TCP and OPC-UA.
- With vertical mounting, installation in the Zero-U space of the Rittal VX IT or TS IT rack can be carried out without tools
- Colour marking of phases and fused circuits (L1=pink, L2=black, L3=white)
- Tool-free installation kit for VX IT
- PDU is self-powered, no external power supply required
- Measuring accuracy ±1 % (kWh) to EN 62 053-21
- Programmable switch-on behaviour after power recovery (on/off/last state)
- Programmable switching behaviour (time/programmable logic)
- Integrated real-time clock with battery backup (max. 10 years, battery replaceable)
- Integrated electromagnetic buzzer for acoustic alarm
- Adjustable limit values (warning/alarm) for voltage, current, power, individually adjustable for each output socket
Scope of supply
- Incl. fixing material
Technical data
| Art. no. | DK 7979435 |
|---|---|
| Version | PDU, managed |
| Technical data | Display/controller unit in the PDU enclosure rotatable by 180° and replaceable Integrated, fully redundant power supply unit, fed from all phases Fault-tolerant PDU power supply, redundant across all phases Voltage V, current A, frequency Hz Active power, active energy, apparent power, apparent energy Power factor (cosPhi) and phase angle Neutral conductor current measurement/unbalanced load detection Fuse monitoring for PDUs with integrated fuse Bright TFT display 128x128 pixels (RGB) with backlight and energy-saving mode for displaying the performance data and the basic PDU configuration Position sensors for display rotation and correct PDU display on the web page Multicolour LEDs (green/yellow/red) for signalling the switching states and limit values for each individual output socket Power LED for voltage indication Energy-saving design, low self-consumption |
| Material | Aluminium profile, black anodised Sockets: plastic |
| Scope of supply | Incl. fixing material |
| Options | Surge protection Type 3 with arresters that can be replaced during operation, with status monitoring, can be integrated in the PDU housing Residual current measurement (Type B) per infeed/phase/fuse Monitoring of the optionally available surge protection CMC III CAN bus sensors for environmental monitoring can be connected, max. 16 sensors Other housing colours possible |
| Description of measuring functions | Emergency supply of the PDU web server via PoE, sequential switch-off of the outputs Switching function per output socket Avoidance of overload peaks: sequential switch-on of the outputs after power recovery Storage of relay switching states even in the event of a power failure Bistable relays: low current consumption and high switching capacity, also for higher inrush currents up to max. 300 A Groupings: joint switching of several outputs Measurement per phase or infeed Additional measurement per output socket High-performance CPU (ARM Cortex A8) Digital input (volt-free contact) Additional alarm output/relay output (changeover contact) |
| Dimension | Width: 44 mm Depth: 70 mm Length: 1,095 mm |
| Number of sockets and type | 18 x C13 / 3 x C19 |
| Socket outlets | 18 x C 13 3 x C 19 |
| Rated operational voltage | 400 V (AC) |
| Rated current (max.) | 16 A |
| Rated power | 11 kW |
| Feeds | Number: 1 Phases per feed: 3~ |
| Connection cable length | 3 m |
| Connection type (electrical) | CEE |
| Interfaces | USB 2.0 port (USB-A) for bulk configuration, firmware update & data logging CAN bus interface (RJ45) for max. 16 environmental sensors Serial interface RS232 (RJ12) for LTE Unit, scripting, CLI Use of own certificates/TLS 1.2 Email dispatch on alarm (SMTP) User management incl. rights management LDAP(S)/RADIUS/Active Directory integration Syslog server integration (max. 2 servers) Fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Directives | EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP TCP/IP v4 & v6, DHCP, DNS SNMP v1, v2c & v3, Modbus/TCP, OPC-UA MIB for integration into 3rd party DCIM software FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Enclosure type: VX IT enclosure frame: ≥ 1,200 mm Enclosure type: VX IT 19" support rails: ≥ 1,800 mm |
| Packaging unit | 1 piece |
| Net weight | 4 kg |
| Gross weight | 5 kg |
| Customs tariff number | 85366990 |
| EAN | 4028177948198 |
| ETIM 9 | EC002762 |
| ECLASS 8.0 | 27142604 |
Specification text
Rittal PDU Managed art. no.: DK 7979.435
Compact power distribution for use in IT server and
network enclosures. Vertical mounting in the Zero-U space using the universal bracket supplied. Suitable for tool-free quick mounting in the Rittal VX IT and
TS IT rack by means of special
plug & play fixing supplied. Robust aluminium
housing with permanently mounted output sockets, depending on type IEC 60320/C13 or IEC 60320/C19 as well as
CEE 7/3 (Schuko) and BS 1363 (UK) (exact version see below). The IEC C13/C19
output sockets can be protected against accidental unplugging of the plugs with a locking device. Unused sockets can be closed with socket covers available as accessories. This rules out unintentional
overloading of individual phases & circuits. The fused circuits or
phases are colour-marked on multi-phase PDU versions. Depending on the version<(>,<)> a fixed connecting cable with IEC C20 or
CEE plug is fitted, so the PDU is ready for immediate use.
The PDU Managed features extensive
measuring and switching function for current <(>&<)>
power monitoring per output socket.
Via the integrated TFT colour display, the
basic configuration can be set and quick
access to the electrical consumption data can be gained. Via two Gigabit
network interfaces and the integrated
web server, remote access and
data transmission via various protocols are possible.
The consumption parameters can be forwarded to a DCIM software via SNMP<(>,<)>
OPC-UA, Modbus/TCP. To monitor the
environmental parameters, up to 16 sensors (e.g. temperature / humidity / smoke / leakage / access) as well as VX IT and TS IT handle systems from the
CMC accessories range can be connected to the CAN sensor interface.
Optionally, the PDU can be fitted at the feed with a
can be fitted with a surge protection module (Type 3) with surge arresters that can be replaced during operation.
With intelligent PDUs, the status is monitored.
The PDU basic series has a volt-free signalling contact for monitoring the surge protection. Optionally, all PDU
versions, except the PDU basic series, are available with all-current-sensitive residual current monitoring (RCM type B) with up to 6 measuring points. This changes the PDU length or the number of installed sockets per standard length.
Technical specifications PDU Managed
Input voltage range (L1-L2-L3/N/PE): 400 VAC, 50-60 Hz
Input current: 16A
Number of phases: 3
Marking of phases (only 3-phase PDUs: L1, L2, L3):
powerpink, black, white
Number of sockets type IEC 60320/C13 (total): 18
Number of sockets type IEC 60320/C13 (per phase/fuse): 6
Number of sockets type IEC 60320/C19 (total): 3
Number of sockets type IEC 60320/C19 (per phase/fuse): 1
Number of sockets type CEE 7/3 (total): -
Number of sockets type CEE 7/3 (per phase/fuse): -
Number of circuit breakers: -
Hydraulic-magnetic circuit breaker: 16 A
Slots individually switchable: yes
PDU input connector plug:
IEC 60309 / CEE (3L+N+PE, 6h)
Length of connecting cable: 3 m
Connecting cable type: H05-VV
Number of cores: 5
Cable cross-section: 2.5 mm²
PDU housing width: 44 mm
PDU housing depth: 70 mm
PDU housing height: 1095 mm
PDU material: aluminium, anodised in RAL9005 (black)<(>,<)> other colours available on request
PDU mounting adaptor (VX IT / TS IT) installation:
Frame + Zero-U space + cable tray
Measuring functions: measurement per output or slot
Switching function: switching per output socket
Measured values (per phase): voltage (V), current (A)<(>,<)>
frequency (Hz), active power (kW), active energy (kWh)<(>,<)>
apparent energy (kVAh), apparent power (kVA)<(>,<)>
reactive power (var), power factor<(>,<)>
THD (voltage and current) for 3-phase<(>,<)>
Crest factor for 1-phase, neutral conductor current measurement
Fuse monitoring (at 32 A); optional:
Residual current measurement (RCM): AC + DC (RCM Type B) max. 6 measuring points per PDU possible (input / per phase / per fuse) 0 mA – 100 mA per RCM
Voltage measuring range: 90V - 255V
Voltage resolution 0.1 V
Current measuring range 0 - 16A/32A
Current resolution 0.1 A
Measuring accuracy typ. ± 1% to IEC/EN 62 053-21
Freely adjustable limit values (warning/alarm) for voltage, current, power: yes
Operating hours counter: yes
Display: TFT, RGB 128x128 pixels
Network interfaces: 2xRJ45, each 10/100/1000 Mbit/s
Controller board: rotatable and replaceable during operation
Supported protocols: IPv4 / IPv6<(>,<)> integrated web server, HTTP, HTTPS, SSL, SSH<(>,<)>
NTP, Telnet, TCP/IP v4 and v6, DHCP, DNS, NTP<(>,<)>
Syslog, SNMP v1, v2c and v3, traps<(>,<)>
OPC-UA, Modbus/TCP<(>,<)>
FTP/SFTP (update / file transfer)<(>,<)>
Email sending (SMTP)
User management incl. rights management: yes
LDAP(S) / Radius connection: yes
USB port for firmware update / data logging function: yes
Initial commissioning/mass configuration:
Yes, via predefined CSV file
CAN bus interface: RJ45, for connection of 16 sensors
CAN sensor types: temperature<(>,<)>
temperature/humidity (combined), infrared access sensor<(>,<)>
leakage, airflow, EFD, NH measuring module, smoke detector<(>,<)>
vandalism, differential pressure
VX IT / TS IT handle system
Plug & play driver in Rittal RiZone DCIM software: yes
Digital input: 1
Alarm relay: 48V DC/2A
Acoustic signal sounder
Serial interface:
RS232 (RJ 12) e.g. for LTE unit 7030.571
Conformity: CE
Standards:
Safety: EN 62368
EMC:
EN 55022 / B
EN 61000-4-2
EN 61000-4-3
EN 61000-6-2
EN 61000-6-3
Low Voltage Directive: 2014/35/EU
EMC Directive: 2014/30/EU
MTBF (at 40°C) 100,000 hours
Protection category: IP20 (EN 60529)
Protection class: Class 1
Pollution degree: 2
Overvoltage category: II
Environmental properties: 2011/65/EU (RoHS 2), WEEE
Storage temperature: -20°C to +70°C
Ambient temperatures +5°C to +50°C
Ambient humidity: 10 - 95% RH, non-condensing
Operating altitude (max. above sea level): 3000 m
Plug locking C14 and C20: 1x (further optional DK 7979.020)
Covers C13 (optional accessory): DK 7955.010
Covers C19 (optional accessory): DK 7955.015
Type: Rittal PDU Managed art. no.: DK 7979.435
PDU managed 16A/3P CEE 18xC13 / 3xC19
Frequently asked questions about Rittal DK 7979.435
What is included in the scope of supply of the Rittal DK 7979.435?
Incl. fixing material.
Can overload peaks be avoided when switching on the outputs?
Yes. After power recovery, the outputs are switched on sequentially, which avoids overload peaks.
Which accessories fit the Rittal DK 7979.435?
You will find matching genuine Rittal accessories directly on this page in the “Matching accessories” section, sorted by category.
Approvals and certificates
- Cyber Security Certificate
- TÜV-tested security
- Declaration of conformity
Downloads from Rittal
- Instructions (DE)
- Quick start guide (DE, EN, FR)
- Additional instructions (DE)
Matching accessories
Zubehör IT-Monitoring (2)
IIoT-Lösungen (2)
Access Control und Lesegeräte (1)
Zubehör (1)
Zubehör IT-Power (4)
Messung und Schutz (2)
Sensoren und Steuereinheiten (7)
More sizes in this series
PDU managed (20)
Service that moves professionals forward
We know the requirements of the workshop, the plant and production.
That is why you get more from us than product information: precise sizing, standards know-how and the right accessories from a single source.
FAQ
Is matching accessories available?
You can see matching mounting, climate control or wiring components above in the “Extensions & accessories” section.
How can I reach support?
Telephone: +49 (0) 151 100 25 806 (Mon. - Fri. 09:00 - 18:00)
Email: support@iam24.de