{"product_id":"rittal-dk-7979821-pdu-uk-ausfuehrung-metered","title":"Rittal DK 7979.821 PDU UK, Ausführung metered, 44x70 mm (BxT), Nennstrom (max.) 13 A","description":"\u003cdiv style=\"border:1px solid #e3e3e3;border-radius:6px;background:#f8f9fa;padding:14px 18px;margin:0 0 18px\"\u003e\n\u003cp style=\"margin:0 0 8px\"\u003e\u003cstrong\u003eAuf einen Blick\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArtikelnummer:\u003c\/strong\u003e DK 7979.821 (7979821)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassend für:\u003c\/strong\u003e VX IT Schrankrahmen: ≥ 1.800 mm · Gehäusetyp: VX IT 19\"-Profilschienen: ≥ 1.800 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNennstrom (max.):\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerpackungseinheit:\u003c\/strong\u003e 1 Stück\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4028177948624\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003eDer \u003cstrong\u003eRittal DK 7979.821\u003c\/strong\u003e (PDU UK, Ausführung metered; Nennstrom (max.) 13 A) ist ein Original-Rittal-Artikel. Die Energieverteilung ist speziell für Rechenzentren und freistehende Racks mit UK (BS 1363) Gerätesteckern ausgelegt.\u003c\/p\u003e\u003cp\u003eDie Rittal PDU UK in der Ausführung metered ist eine Energieverteilung für Rechenzentren und freistehende Racks mit UK-Gerätesteckern (BS 1363). Die Ausführung 19\" \/ Metered UK verfügt über Messfunktionen zur Strom- und Leistungsüberwachung je Phase. Das Gehäuse besteht aus schwarz eloxiertem Aluminiumprofil, die Steckplätze aus Kunststoff.\u003c\/p\u003e\u003cp\u003eDas integrierte TFT-Farbdisplay dient der Grundkonfiguration und dem schnellen Zugriff auf die elektrischen Verbrauchsdaten; über den integrierten Webserver ist Fernzugriff möglich. Als Nachweise sind Cyber Security Certificate, Konformitätserklärung und TÜV-Geprüfte Sicherheit angegeben.\u003c\/p\u003e\u003ch2\u003eVorteile und Merkmale\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeitungsschutz:\u003c\/strong\u003e Kompakte Leitungsschutzschalter (16 A, Carling type).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFarbmarkierung:\u003c\/strong\u003e Phasen und Sicherungsstromkreise sind farblich gekennzeichnet (L1=pink, L2=schwarz, L3=weiß).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmgebungsüberwachung:\u003c\/strong\u003e CMC III CAN-Bus-Sensoren sind anschließbar, maximal 16 Sensoren.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontage:\u003c\/strong\u003e Vertikale Montage im Zero-U-Bereich mit dem mitgelieferten Universalhalter; Plug-\u0026amp;-Play-Befestigung für VX IT und TS IT Racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRichtlinien und Normen:\u003c\/strong\u003e EMV-Richtlinie 2014\/30\/EU, Niederspannungsrichtlinie 2014\/35\/EU sowie EN 62368-1, EN 61000-3, -4, -6 und EN 62053-21.\u003c\/li\u003e\n\u003cli\u003eWerkzeugloser Einbausatz für VX IT\u003c\/li\u003e\n\u003cli\u003eStromsparendes Design, geringer Eigenverbrauch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eLieferumfang\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eInkl. Befestigungsmaterial\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eTechnische Daten\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eArtikel-Nr.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eDK 7979821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAusführung\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAusführung 19\"\u003cbr\u003eMetered UK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eTechnische Daten\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eFarbliche Markierung von Phasen und Sicherungsstromkreisen (L1=pink, L2=schwarz, L3=weiß)\u003cbr\u003eKompakte Leitungsschutzschalter (16 A - Carling type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAluminiumprofil, schwarz eloxiert\u003cbr\u003eSteckplätze: Kunststoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eLieferumfang\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eInkl. Befestigungsmaterial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eOptionen\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eÜberspannungschutz Typ 3 mit im Betrieb tauschbaren Ableitern, mit Statusüberwachung, in PDU Gehäuse integrierbar\u003cbr\u003eCMC III CAN-Bus-Sensoren zur Umgebungsüberwachung anschließbar, max. 16 Sensoren\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAbmessung\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eBreite: 44 mm\u003cbr\u003eTiefe: 70 mm\u003cbr\u003eLänge: 1.295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAnzahl Steckdosen und Typ\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 x BS 1363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eSteckdosen\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e16 x BS 1363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNennstrom (max.)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNennleistung\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEinspeisungen\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eAnzahl: 1\u003cbr\u003ePhasen pro Einspeisung: 1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eLänge Anschlussleitung\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eAnschlussart (elektrisch)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eUK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eRichtlinien\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEMV-Richtlinie 2014\/30\/EU\u003cbr\u003eNiederspannungsrichtlinie 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eNormen\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eBetriebstemperaturbereich\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e5 °C...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eLuftfeuchtigkeit (nicht kondensierend)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e10...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eLagertemperaturbereich\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e-25 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003ePassend für\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eGehäusetyp: VX IT Schrankrahmen: ≥ 1.800 mm\u003cbr\u003eGehäusetyp: VX IT 19\"-Profilschienen: ≥ 1.800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eVerpackungseinheit\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e1 Stück\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eZolltarifnummer\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eEAN\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e4028177948624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 9\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC000330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eETIM 8\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003eEC002762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #ddd;background:#f6f6f6\"\u003eECLASS 8.0\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #ddd\"\u003e27142604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cdetails style=\"margin:12px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600\"\u003eAusschreibungstext\u003c\/summary\u003e\u003cp\u003e\u003cstrong\u003eRittal PDU Metered Art.-Nr.: DK 7979.821\u003c\/strong\u003e\u003cbr\u003eKompakte Stromverteilung zum Einsatz in IT-Server und\u003cbr\u003eNetzwerkschränken. Vertikale Montage im Zero-U Bereich durch den mitgelieferten Universalhalter. Zur werkzeuglosen Schnellmontage im Rittal VX IT und\u003cbr\u003eTS IT Rack mittels spezieller mitgelieferten\u003cbr\u003ePlug \u0026amp; Play Befestigung geeignet. Robustes Aluminium-\u003cbr\u003eGehäuse mit fest montierten Ausgangssteckplätzen je nach Typ IEC 60320\/C13 bzw. IEC 60320\/C19 sowie\u003cbr\u003eCEE 7\/3 (Schuko) und BS 1363 (UK) (genaue Ausführung siehe unten). Die IEC C13\/C19\u003cbr\u003eAusgangssteckplätze können mit einer Verriegelung gegen versehentliches Abziehen der Stecker geschützt werden. Nicht benutzte Steckplätze können mittels im Zubehör erhältlichen Steckplatz-Abdeckungen verschlossen werden. Dadurch ist eine unabsichtliche\u003cbr\u003eÜberlastung einzelnen Phasen \u0026amp; Stromkreise ausgeschlossen. Die Sicherungsstromkreise bzw.\u003cbr\u003ePhasen sind bei mehrphasigen PDU Ausführungen farblich markiert. Der Ausführung entsprechend\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; ist ein festes Anschlusskabel mit IEC C20 bzw.\u003cbr\u003eCEE-Stecker montiert, somit ist die PDU sofort einsatzbereit.\u003cbr\u003eDie PDU Metered verfügt über umfangreiche\u003cbr\u003eMessfunktionen zur Strom- \u0026amp; Leistungsüberwachung je Phase. Über das integrierte TFT-Farbdisplay kann die Grundkonfiguration eingestellt und der schnelle Zugriff auf die elektrischen Verbrauchsdaten durchgeführt werden. Über zwei Gigabit-Netzwerk- schnittstellen und den integrierten Webserver ist ein Fernzugriff und eine Datenübertragung über diverse\u003cbr\u003eProtokolle möglich. Die Verbrauchsparameter können über\u003cbr\u003eSNMP, OPC-UA,Modbus\/TCP an eine DCIM Software weitergeleitet werden. Zur Überwachung der\u003cbr\u003eUmgebungsparameter können bis zu 16 Sensoren (z.B.: Temperatur \/ Feuchte \/ Rauch \/ Leckage \/ Zugang sowie VX IT und TS IT Griffsysteme) aus dem\u003cbr\u003eCMC Zubehörprogramm an die CAN-Sensor-Schnittstelle angeschlossen werden.\u003cbr\u003eOptional kann die PDU an der Einspeisung mit einem\u003cbr\u003eÜberspannungsschutzmodul (Typ 3) mit im Betrieb tauschbaren Ableitern bestückt werden.\u003cbr\u003eBei intelligenten PDUs wird der Status überwacht.\u003cbr\u003eDie PDU basic Serie verfügt zur Überwachung des Überspannungsschutzes über einen potenzialfreien Meldekontakt. Optional sind alle PDU\u003cbr\u003eVersionen, außer die PDU basic Serie, mit einer allstromsensitiven Differenzstrommessung (RCM Typ B) mit bis zu 6 Messpunkten lieferbar. Dadurch ändert sich die PDU Länge bzw. die Anzahl der verbauten Steckplätze je Standardlänge.\u003cbr\u003eTechnische Spezifikationen PDU Metered\u003cbr\u003eEingangsspannungsbereich (L\/N\/PE): 230 VAC, 50-60Hz\u003cbr\u003eEingangsstrom: 13A\u003cbr\u003eAnzahl der Phasen: 1\u003cbr\u003eMarkierung der Phasen (nur 3-phasige PDUs:L1, L2, L3):\u003cbr\u003epowerpink, schwarz, weiß\u003cbr\u003eAnzahl Steckplätze Typ BS1363 (gesamt): 16\u003cbr\u003eAnzahl Steckplätze Typ IEC 60320\/C19 (gesamt): -\u003cbr\u003eAnzahl Schutzschalter: -\u003cbr\u003eHydraulisch magnetischer Schutzschalter: 16 A\u003cbr\u003eAnschlussstecker PDU Eingang: BS1363\u003cbr\u003eLänge des Anschlusskabels: 3m\u003cbr\u003eAnschlusskabel-Typ: H05-VV\u003cbr\u003eAderanzahl: 3\u003cbr\u003eKabelquerschnitt: 1,5mm²\u003cbr\u003ePDU Gehäusebreite: 44mm\u003cbr\u003ePDU Gehäusetiefe: 70mm\u003cbr\u003ePDU Gehäusehöhe: 1295mm\u003cbr\u003ePDU Material: Aluminium, eloxiert in RAL9005 (schwarz)\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt; weitere Farben auf Anfrage verfügbar\u003cbr\u003ePDU Befestigungsadapter (VX IT \/ TS IT) Montage:\u003cbr\u003eRahmen + Zero-U Space + Kabeltrasse\u003cbr\u003eMessfunktionen: Messung je Phase, bzw. Einspeisung\u003cbr\u003eErfasste Werte (pro Phase):\u003cbr\u003eSpannung (V), Strom (A), Frequenz (Hz)\u003cbr\u003eWirkleistung (kW),Wirkarbeit (kWh),Scheinleistung (kVA)\u003cbr\u003ePowerfaktor, Neutralleiterstrommessung\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eSicherungsüberwachung (bei 32 A)\u003cbr\u003eOptional: Differenzstrommessung (RCM)\u003cbr\u003eAC + DC (RCM Typ B) max. 6 Messstellen je PDU möglich (Eingang \/ je Phase \/ je Sicherung) 0 mA – 100 mA je RCM\u003cbr\u003eSpannung Messbereich: 90V - 255V\u003cbr\u003eSpannung Auflösung 0,1V\u003cbr\u003eSpannung Genauigkeit 2%\u003cbr\u003eStrom Messbereich 0 - 16A\/32A\u003cbr\u003eStrom Auflösung 0,1A\u003cbr\u003eStrom Genauigkeit 2%\u003cbr\u003eFrequenz Genauigkeit 2%\u003cbr\u003eWirkleistung (kW) Genauigkeit 2%\u003cbr\u003eScheinleistung (kVA) Genauigkeit 2%\u003cbr\u003eWirkarbeit (kWh) Genauigkeit 1%\u003cbr\u003ePowerfaktor Genauigkeit 2%\u003cbr\u003eFrei einstellbare Grenzwerte (Warnung\/Alarm) für für Spannung, Strom, Leistung: Ja\u003cbr\u003eBetriebsstundenzähler: Ja\u003cbr\u003eDisplay \/ Anzeige: TFT, RGB 128x128Pixel\u003cbr\u003eNetzwerkschnittstellen: 2xRJ45, je 10\/100\/1000 MBit\/s\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eNetzwerkschnittstelle: RJ45, integrierter Webserver\u003cbr\u003eUnterstützte Protokolle:\u003cbr\u003eHTTP, HTTPS, SSL, SSH, NTP, Telnet\u003cbr\u003eTCP\/IP v4 und v6, DHCP, DNS, NTP, Syslog\u003cbr\u003eSNMP v1, v2c und v3, XML\u003cbr\u003eFTP\/SFTP (Update \/ Filetransfer)\u003cbr\u003eE-Mail-Versand (SMTP)\u003cbr\u003eNutzerverwaltung inkl. Rechtemanagement: Ja\u003cbr\u003eLDAP(S) \/ Radius \/ Active Directory Anbindung: Ja\u003cbr\u003eUSB-Port für Firmwareupdate und Datalogging-Funktion: Ja\u003cbr\u003eCAN-Bus Schnittstelle:RJ45, Anschluss von 16 Sensoren\u003cbr\u003eCAN-Sensoren-Typen: Temperatur\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eTemperatur\/Feuchte (Kombi), Infrarot-Zugangssensor\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eLeckage, NH-Messmodul, Rauchmelder, Vandalismus\u0026lt;(\u0026gt;,\u0026lt;)\u0026gt;\u003cbr\u003eLuftstrom, EFD, Differenzdruck, VX IT\/TS IT Griffsystem\u003cbr\u003ePlug \u0026amp; Play Treiber in Rittal RiZone DCIM Software: Ja\u003cbr\u003eDigitaler Eingang: 1\u003cbr\u003eAlarmrelais: 48V DC\/2A\u003cbr\u003eAkustischer Signalgeber\u003cbr\u003eSerielle Schnittstelle\u003cbr\u003eKonformität: CE\u003cbr\u003eNormen:\u003cbr\u003eSicherheit: EN 62368\u003cbr\u003eEMV:\u003cbr\u003eEN 55022 \/ B\u003cbr\u003eEN 61000-4-2\u003cbr\u003eEN 61000-4-3\u003cbr\u003eEN 61000-6-2\u003cbr\u003eEN 61000-6-3\u003cbr\u003eSicherheitsrichtlinie: 2014\/35\/EU\u003cbr\u003eEMV Richtlinie: 2014\/30\/EU\u003cbr\u003eMTBF (bei 40°C) 100.000 Stunden\u003cbr\u003eSchutzart: IP 20 (EN 60529)\u003cbr\u003eSchutzklasse: Klasse 1\u003cbr\u003eVerschmutzungsgrad: 2\u003cbr\u003eÜberspannungsklasse: II\u003cbr\u003eUmwelteigenschaften: 2011\/65\/EU (RoHS 2), WEEE\u003cbr\u003eLagertemperatur -20°C bis +70°C\u003cbr\u003eUmgebungstemperaturen +5°C bis +50°C\u003cbr\u003eUmgebungsfeuchte 10 - 95% rF, nicht kondensierend\u003cbr\u003eBetriebshöhe (max. ü. N.N.): 3000m\u003cbr\u003eStecker Verriegelung C14 und C20:\u003cbr\u003e1x (weitere optional DK 7979.020)\u003cbr\u003eAbdeckungen C13 (optionales Zubehör): DK 7955.010\u003cbr\u003eAbdeckungen C19 (optionales Zubehör): DK 7955.015\u003cbr\u003eTyp: Rittal PDU Metered Art.-Nr.: DK 7979.821\u003cbr\u003ePDU metered UK 13A\/1P 16x UK-Plug(BS1363)\u003cbr\u003eRittal PDU metered, Model No.: DK 7979.821\u003c\/p\u003e\u003c\/details\u003e\u003ch2\u003eHäufige Fragen zum Rittal DK 7979.821\u003c\/h2\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWas ist im Lieferumfang des Rittal DK 7979.821 enthalten?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eInkl. Befestigungsmaterial.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eKann die PDU UK metered mit Überspannungsschutz ausgestattet werden?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003eJa. Als Option ist ein Überspannungsschutz Typ 3 mit im Betrieb tauschbaren Ableitern und Statusüberwachung verfügbar, der sich in das PDU-Gehäuse integrieren lässt.\u003c\/p\u003e\u003ch3 style=\"font-size:1em;margin:14px 0 4px\"\u003eWelches Zubehör passt zum Rittal DK 7979.821?\u003c\/h3\u003e\u003cp style=\"margin:0 0 8px\"\u003ePassendes Original-Rittal-Zubehör finden Sie direkt auf dieser Seite im Bereich „Passendes Zubehör“, sortiert nach Kategorien.\u003c\/p\u003e\u003ch2\u003eZulassungen und Zertifikate\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCyber Security Certificate\u003c\/li\u003e\n\u003cli\u003eTÜV-Geprüfte Sicherheit\u003c\/li\u003e\n\u003cli\u003eKonformitätserklärung\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDownloads von Rittal\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8425\/7979821_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eAnleitung\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8259\/7979821_Kurzanleitung_DE_EN_FR\" target=\"_blank\" rel=\"noopener\"\u003eKurzanleitung\u003c\/a\u003e (DE, EN, FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rittal.com\/imf\/none\/3_8426\/7979821_Zus_auml_tzliche_Anleitung_DE\" target=\"_blank\" rel=\"noopener\"\u003eZusätzliche Anleitung\u003c\/a\u003e (DE)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rittal","offers":[{"title":"Default Title","offer_id":66377862906205,"sku":"7979821","price":673.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0902\/1692\/3485\/files\/rittal-dk-7979821-pdu-basic-uk-13a-230v.jpg?v=1793628208","url":"https:\/\/www.iam24.de\/products\/rittal-dk-7979821-pdu-uk-ausfuehrung-metered","provider":"IAM24","version":"1.0","type":"link"}